Decentralized Parallel Operation of Inverters Sharing Unbalanced and Nonlinear Loads
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
In this paper, a wireless control strategy for parallel operation of three-phase four-wire inverters is proposed. A generalized situation is considered where the inverters are of unequal power ratings and the loads are nonlinear and unbalanced in nature. The proposed control algorithm exploits the potential of sinusoidal domain proportional+multiresonant controller (in the inner voltage regulation loop) to make the system suitable for nonlinear and unbalanced loads with a simple and generalized structure of virtual output-impedance loop. The decentralized operation is achieved by using three-phase P/Q droop characteristics. The overall control algorithm helps to limit the harmonic contents and the degree of unbalance in the output-voltage waveform and to achieve excellent power-sharing accuracy in spite of mismatch in the inverter output impedances. Moreover, a synchronized turn on with consequent change over to the droop mode is applied for the new incoming unit in order to limit the circulating current completely. The simulation and experimental results from -1 kVA and -0.5 kVA paralleled units validate the effectiveness of the scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Microgrid: a conceptual solution
Lasseter, R. H., & Paigi, P. (2004) · 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · doi:10.1109/pesc.2004.1354758 · Cited by 1,726
Mohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Guerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
He, J., & Li, Y. W. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168592 · Cited by 759
Virtual-Impedance-Based Control for Voltage-Source and Current-Source Converters
Wang, X., Li, Y. W., Blaabjerg, F., & Loh, P. C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2382565 · Cited by 670
Accurate Reactive Power Sharing in an Islanded Microgrid Using Adaptive Virtual Impedances
Mahmood, H., Michaelson, D., & Jiang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2314721 · Cited by 453
An Enhanced Microgrid Load Demand Sharing Strategy
He, J., & Li, Y. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2190099 · Cited by 429
Distributed Control Strategies for Microgrids: An Overview
Espina, E., Llanos, J., Burgos-Mellado, C., Cardenas-Dobson, R., Martinez-Gomez, M., & Saez, D. (2020) · IEEE Access · doi:10.1109/access.2020.3032378 · Cited by 415
Synchronization of Parallel Single-Phase Inverters With Virtual Oscillator Control
Johnson, B. B., Dhople, S. V., Hamadeh, A. O., & Krein, P. T. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2296292 · Cited by 352
Power Quality Control of Smart Hybrid AC/DC Microgrids: An Overview
Nejabatkhah, F., Li, Y. W., & Tian, H. (2019) · IEEE Access · doi:10.1109/access.2019.2912376 · Cited by 258
Lee, T.-L., Hu, S.-H., & Chan, Y.-H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2166233 · Cited by 216
“The concept of inverter-based RESs with functionality of VAr supporting was presented to accomplish voltage regulation locally [18]–[22].”
BackgroundHan, Y., Shen, P., Zhao, X., & Guerrero, J. M. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2552497 · Cited by 209
“To achieve the power sharing requirement with only local measurement and eliminating an external high bandwidth communication links among the DG units, the frequency and voltage droop control methods are widely adopted [3-10] and the “plug-and-play” interfacing functions can be applied to enhance the reliability of th…”
MethodEid, B. M., Rahim, N. A., Selvaraj, J., & Elkhateb, A. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2013.2296075 · Cited by 188
Reactive Power Sharing in Islanded Microgrids Using Adaptive Voltage Droop Control
Mahmood, H., Michaelson, D., & Jiang, J. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2399232 · Cited by 185
Decentralized Power Management of a PV/Battery Hybrid Unit in a Droop-Controlled Islanded Microgrid
Mahmood, H., Michaelson, D., & Jiang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2394351 · Cited by 169
“Therefore, these control strategies cannot be applied directly to an islanded microgrid containing multiple units, such as droopcontrolled units which are widely adopted in the literature [5], [13], [14], [20]–[23].”
Background
Metadata
- Authors
- De, D., & Ramanarayanan, V.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-12
- Volume
- 25
- Issue
- 12
- Pages
- 3015-3025
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2105840500
- Cited by
- 276
- References
- 15
- FWCI
- 22.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.