The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Grid-Fault Control Scheme for Three-Phase Photovoltaic Inverters With Adjustable Power Quality Characteristics
Open accessAbstract
The power quality of a three-phase photovoltaic (PV) inverter drastically deteriorates in the presence of grid faults with unbalanced voltages. A ripple in the injected power and an increase in the current harmonic distortion are the main noticeable adverse effects produced by this abnormal grid situation. Several grid-fault control schemes are nowadays available for operating under unbalanced grid voltage. These control schemes usually have extreme power quality characteristics. Some of them have been conceived to completely avoid power ripple during unbalanced voltage sags, but at an expense of high current harmonic distortion. With other schemes, the harmonic distortion is totally eliminated but at an expense of high ripple in the injected power. This paper further explores the performance of PV inverters under unbalanced voltage sags. It has three theoretical contributions: 1) a generalized control scheme, which includes the aforementioned grid-fault controllers as particular cases; 2) a control strategy based on the use of continuous values for the control parameters. This original approach gives adjustable power quality characteristics that cannot be achieved with the previous control schemes; 3) three different control algorithms for calculating the continuous values of the control parameters. These contributions are experimentally validated with a digital signal processor-based laboratory prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Self-citation
Cited by
Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault
Camacho, A., Castilla, M., Miret, J., Vasquez, J. C., & Alarcon-Gallo, E. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2185016 · Cited by 339
Self-citationAfshari, E., Moradi, G. R., Rahimi, R., Farhangi, B., Yang, Y., Blaabjerg, F., & Farhangi, S. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2733481 · Cited by 259
Metadata
- Authors
- Castilla, M., Miret, J., Sosa, J. L., Matas, J., & Vicuña, L. G. D.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-12
- Volume
- 25
- Issue
- 12
- Pages
- 2930-2940
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2140361514
- Cited by
- 192
- References
- 1
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grid-Fault Control Scheme for Three-Phase Photovoltaic Inverters With Adjustable Power Quality Characteristics. https://app.cochat.ai/papers/10.1109/tpel.2010.2070081
- The paper
- Castilla, M., Miret, J., Sosa, J. L., Matas, J., & Vicuña, L. G. D. (2010). Grid-Fault Control Scheme for Three-Phase Photovoltaic Inverters With Adjustable Power Quality Characteristics. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2010.2070081
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.