Grid-Fault Control Scheme for Three-Phase Photovoltaic Inverters With Adjustable Power Quality Characteristics
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The power quality of a three-phase photovoltaic (PV) inverter drastically deteriorates in the presence of grid faults with unbalanced voltages. A ripple in the injected power and an increase in the current harmonic distortion are the main noticeable adverse effects produced by this abnormal grid situation. Several grid-fault control schemes are nowadays available for operating under unbalanced grid voltage. These control schemes usually have extreme power quality characteristics. Some of them have been conceived to completely avoid power ripple during unbalanced voltage sags, but at an expense of high current harmonic distortion. With other schemes, the harmonic distortion is totally eliminated but at an expense of high ripple in the injected power. This paper further explores the performance of PV inverters under unbalanced voltage sags. It has three theoretical contributions: 1) a generalized control scheme, which includes the aforementioned grid-fault controllers as particular cases; 2) a control strategy based on the use of continuous values for the control parameters. This original approach gives adjustable power quality characteristics that cannot be achieved with the previous control schemes; 3) three different control algorithms for calculating the continuous values of the control parameters. These contributions are experimentally validated with a digital signal processor-based laboratory prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220 · cited 3×
“schemes normally make use of novel proportional-resonant compensators for current regulation [27].”
BackgroundMethodInfluentialGuerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Self-citationMohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Evaluation of Current Controllers for Distributed Power Generation Systems
Timbus, A., Liserre, M., Teodorescu, R., Rodriguez, P., & Blaabjerg, F. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2012527 · Cited by 934 · cited 2×
“This idea was later successfully applied to other applications such as active power filters [17]–[19], static synchronous compensators [20]–[22], and grid-connected photovoltaic (PV) inverters [23], [24].”
BackgroundMethodDual current control scheme for PWM converter under unbalanced input voltage conditions
Song, H.-S., & Nam, K. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793344 · Cited by 930 · cited 3×
“In particular, the reduction of the power quality caused by a ripple in the output power and an increase of the current harmonic distortion is the most significant impact of unbalanced voltage sags [11], [12].”
BackgroundControl Strategy for Flexible Microgrid Based on Parallel Line-Interactive UPS Systems
Guerrero, J. M., Vasquez, J. C., Matas, J., Castilla, M., & de Vicuna, L. G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009274 · Cited by 788 · cited 1×
“In this scenario, power-electronic-based microgrids have received increasing attention in low-voltage network applications [1]–[4].”
BackgroundSelf-citationEnergy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001910 · Cited by 733 · cited 1×
“Connected to the utility grid by power inverters, these microgrids are generally conceived as an autonomous cluster of paralleled distributed microgeneration systems operating in a common local area [5].”
BackgroundFlexible Active Power Control of Distributed Power Generation Systems During Grid Faults
Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899914 · Cited by 726 · cited 4×
“Additional information of these reference currents including derivation, physical interpretation and discussion can be found in [25]–[28].”
BackgroundInfluentialComparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems
Montero, M. I. M., Cadaval, E. R., & Gonzalez, F. B. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886616 · Cited by 582
Cited by
Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault
Camacho, A., Castilla, M., Miret, J., Vasquez, J. C., & Alarcon-Gallo, E. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2185016 · Cited by 339
Self-citationAfshari, E., Moradi, G. R., Rahimi, R., Farhangi, B., Yang, Y., Blaabjerg, F., & Farhangi, S. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2733481 · Cited by 259
Miret, J., Castilla, M., Camacho, A., Vicuña, L. G. D., & Matas, J. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2191306 · Cited by 243
“In [23] and [24], the selection of a proper reference current is proposed to override grid faults and achieve different power quality requirements.”
BackgroundSelf-citationMatas, J., Castilla, M., Miret, J., Garcia de Vicuna, L., & Guzman, R. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2274414 · Cited by 233
“There are several control strategies for setting the current references to operate the three-phase inverter during voltage sags [16], [17].”
BackgroundMethodSelf-citationPV Power System With Multi-Mode Operation and Low-Voltage Ride-Through Capability
Tang, C.-Y., Chen, Y.-T., & Chen, Y.-M. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2449777 · Cited by 174
“are proposed to achieve better performance of the power qualities of the PV inverters under unbalanced grid voltage sags [26]–[28].”
Background
Metadata
- Authors
- Castilla, M., Miret, J., Sosa, J. L., Matas, J., & Vicuña, L. G. D.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2010-12
- Volume
- 25
- Issue
- 12
- Pages
- 2930-2940
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2140361514
- Cited by
- 192
- References
- 19
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.