High Power Current Sensorless Bidirectional 16-Phase Interleaved DC-DC Converter for Hybrid Vehicle Application
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A new 16-phase interleaved bidirectional dc/dc converter is developed featuring smaller input/output filters, faster dynamic response and lower device stress than conventional designs, for hybrid vehicle applications. The converter is connected between the ultracapacitor (UC) pack and the battery pack in a multisource energy storage system of a hybrid vehicle. Typically, multiphase interleaved converters require a current control loop in each phase to avoid imbalanced current between phases. This increases system cost and control complexity. In this paper, in order to minimize imbalance currents and remove the current control loop in each phase, the converter is designed to operate in discontinuous conduction mode (DCM). The high current ripple associated with DCM operation is then alleviated by interleaving. The design, construction, and testing of an experimental hardware prototype is presented, with the test results included. Finally, a novel soft switch topology for DCM operation is proposed for future research, to achieve zero-voltage switching (ZVS), or zero-current switching (ZCS) in all transitions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-power density design of a soft-switching high-power bidirectional dc–dc converter
Zhang, J., Lai, J.-S., Kim, R.-Y., & Yu, W. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900462 · Cited by 411 · cited 4×
“In a synchronous converter in CCM, the duty ratio D′ of the freewheeling MOSFET equals D̄ with necessary dead time.”
BackgroundInfluentialAutomotive DC-DC bidirectional converter made with many interleaved buck stages
Garcia, O., Zumel, P., de Castro, A., & Cobos, A. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.872379 · Cited by 405 · cited 3×
“The optimum number of phases will be another issue that has to be considered [12], [19], [20].”
Background
Cited by
Yilmaz, M., & Krein, P. T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212917 · Cited by 3,118
“duce battery charging current ripple and inductor size [42], [43]; a unidirectional configuration presented in [40] is illustrated in Fig.”
BackgroundKhalid, M. R., Alam, M. S., Sarwar, A., & Jamil Asghar, M. S. (2019) · eTransportation · doi:10.1016/j.etran.2019.100006 · Cited by 369
Ji, B., Pickert, V., Cao, W., & Zahawi, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2251358 · Cited by 329
Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324
“Also for the dc/dc stage, the interleaving concept originated from the multiphase dc/dc converter is adopted to minimize the ripple across the output capacitor [48].”
MethodHossain, M. Z., Rahim, N. A., & Selvaraj, J. A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.017 · Cited by 305
Blanes, J. M., Gutiérrez, R., Garrigós, A., Lizán, J. L., & Cuadrado, J. M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2255316 · Cited by 195
“In [8] and [15], this drawback is overcome by operating the interleaved converter in the discontinuous conduction mode (DCM), with some efficiency penalty, but achieving current Fig.”
BackgroundTan, L., Wu, B., Rivera, S., & Yaramasu, V. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2397453 · Cited by 175
“ing of two interleaved converters [21], [22], [34], [35].”
BackgroundA review of non-isolated bidirectional dc-dc converters for energy storage systems
Tytelmaier, K., Husev, O., Veligorskyi, O., & Yershov, R. (2016) · 2016 II International Young Scientists Forum on Applied Physics and Engineering (YSF) · doi:10.1109/ysf.2016.7753752 · Cited by 174
“The number of phases can be any from 2-4 to 16 [69] or even 36 [70].”
BackgroundMultiphase Interleaved Converter for Lithium Battery Active Balancing
Mestrallet, F., Kerachev, L., Crebier, J.-C., & Collet, A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2276152 · Cited by 165
“Multiphase converters [9], [10] are based on parallel structures which allow an effective sharing of the current flow and of the power losses in each component.”
BackgroundAnalysis and Experimental Verification of a Fault-Tolerant HEV Powertrain
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2245513 · Cited by 81
Non-isolated bidirectional soft-switching SEPIC/ZETA converter with reduced ripple currents
Song, M.-S., Son, Y.-D., & Lee, K.-H. (2014) · Journal of Power Electronics · doi:10.6113/jpe.2014.14.4.649 · Cited by 56
Metadata
- Authors
- Ni, L., Patterson, D. J., & Hudgins, J. L.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2012-03
- Volume
- 27
- Issue
- 3
- Pages
- 1141-1151
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2121339182
- Cited by
- 162
- References
- 2
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.