Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The solid-state transformer (SST) is an interface device between ac distribution grids and dc distribution systems. The SST consists of a cascaded multilevel ac/dc rectifier stage, a dual active bridge (DAB) converter stage with high-frequency transformers to provide a regulated 400-V dc distribution, and an optional dc/ac stage that can be connected to the 400-V dc bus to provide residential 120/240 V$_{\rm ac}$. However, due to dc-link voltage and power unbalance in the cascaded modules, the unbalanced dc-link voltages and power increase the stress of the semiconductor devices and cause overvoltage or overcurrent issues. This paper proposes a new voltage and power balance control for the cascaded H-Bridge converter-based SST. Based on the single-phase dq model, a novel voltage and the power control strategy is proposed to balance the rectifier capacitor voltages and the real power through parallel DAB modules. Furthermore, the intrinsic power constraints of the cascaded H-Bridge voltage balance control are derived and analyzed. With the proposed control methods, the dc-link voltage and the real power through each module can be balanced. The SST switching model simulation and the prototype experiments are presented to verify the performance of the proposed voltage and power balance controller.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530601 · Cited by 2,665 · cited 1×
“The SST has the features of instantaneous voltage regulation, voltage sag compensation, fault isolation, power factor correction, harmonic isolation, and dc output [1]–[4].”
BackgroundMultilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.502161 · Cited by 2,604
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401 · cited 1×
“The low-voltage dc link is regulated by the DAB converter [16], [19].”
BackgroundResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 1×
“One of the main disadvantages of the cascaded H-bridge rectifier is the voltage unbalance of the dc-link voltages at different H-Bridges [5]–[7], [12], [13], [18], [20].”
BackgroundSelf-citationIndividual Voltage Balancing Strategy for PWM Cascaded H-Bridge Converter-Based STATCOM
Barrena, J. A., Marroyo, L., Rodriguez Vidal, M. Á., & Torrealday Apraiz, J. R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906127 · Cited by 335 · cited 1×
“[8] present an individual voltage-balancing strategy to balance the dc-link voltage with PWM.”
BackgroundA power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
A grid simulator with control of single-phase power converters in D-Q rotating frame
Zhang, R., Cardinal, M., Szczesny, P., & Dame, M. (2003) · 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289) · doi:10.1109/psec.2002.1022377 · Cited by 281 · cited 1×
“The single-phase dq transformation is applied to the (5) and (6) [14], and the differential equations in dq coordinates are Fig.”
MethodA Power Electronic-Based Distribution Transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4312081 · Cited by 264
A Modular Strategy for Control and Voltage Balancing of Cascaded H-Bridge Rectifiers
Iman-Eini, H., Schanen, J.-L., Farhangi, S., & Roudet, J. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002055 · Cited by 205 · cited 1×
“[9] present a method that ensures the dc-link voltages converge to the reference value when load power are different.”
MethodMultilevel intelligent universal transformer for medium voltage applications
Lai, J.-S., Maitra, A., Mansoor, A., & Goodman, F. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518705 · Cited by 185
Cited by
Items 301–400 of 651
Post-fault operation of hybrid DC-DC converter for Solid-State Transformer
Gajowik, T., Sobol, C., Styński, S., & Malinowski, M. (2017) · Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2017.8216931 · Cited by 7
Peak Current Control and Feed-Forward Compensation for the DAB Converter
Vázquez, N., & Liserre, M. (2019) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2019.8755238 · Cited by 9
Hybrid Multiple-Active Bridge for Unequal Power Flow in Smart Transformers
Ferreira, V. N., Vázquez, N., Cardoso, B. J., & Liserre, M. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8913049 · Cited by 9
“providing power to all CHB cells in reverse power flow [9].”
BackgroundFast detection of open-switch fault in cascaded H-Bridge multilevel converter
Shahbazi, M., & Zolghadri, M. R. (2015) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc.2015.7093332 · Cited by 9
A capacitor voltage balancing method for a three phase modular multilevel DC-DC converter
Jiang, M., Shao, S., Sheng, K., & Zhang, J. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8095853 · Cited by 9
“To interconnect Micro-grid and utility grid and to manage renewable energy, a power electronic transformer (PET), also known as a solid state transformer (SST), is required, for its capability of power control, voltage sag compensation and fault current limitation [2].”
BackgroundTwo‐voltage hierarchical model predictive control for a single‐phase cascaded H‐bridge rectifier
Qi, C., Chen, X., Su, L., & Lang, Z. (2019) · IET Power Electronics · doi:10.1049/iet-pel.2018.5534 · Cited by 9
A Modular Multilevel Converter with Self Voltage Balancing
Liu, Y., & Peng, F. Z. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8721876 · Cited by 9
Okutani, S., Huang, P.-Y., Nishiyama, R., & Kado, Y. (2022) · IEEE Access · doi:10.1109/access.2022.3142028 · Cited by 9
“is required for a DAB [8]–[11], and an input voltage sharing control is also necessary in the AC/DC stage of a DAB-based cascaded SST [8], [9].”
BackgroundInductor Current Envelope Tracking-Based Sensorless Control of Dual Active Bridge Converter
Nayak, G., & Dasgupta, A. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3151503 · Cited by 10
Sun, Y., Zhao, J., Ji, Z., Yao, X., & Zhu, Z. (2013) · IEEE International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2013.6527210 · Cited by 9
“The voltage balancing method in the d-q coordinate is adopted in the cascaded solid state transformer (SST) in [15][16].”
MethodDutta, S., & Roy, S. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6647345 · Cited by 9
“ALTERNATE DC TO DC STAGE FOR THE SST An alternative to the parallel connected DAB stage may be a multi-limb core topology (MLC) [12] as shown in Fig.”
BackgroundMethodInfluentialAkbariavaz, K., Fazel, S. S., & Khosravi, M. (2021) · IET Power Electronics · doi:10.1049/pel2.12158 · Cited by 9
“IET Power Electronics published by John Wiley & Sons Ltd on behalf of The Institution of Engineering and Technology By reviewing the literature, it could be seen that most research efforts on power electronic transformer (PET) have been devoted to different control objectives such as power control [5], voltage balanci…”
BackgroundAdvanced modeling of solid state transformer
Adabi, M. E. (2018) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-113997 · Cited by 10
ILYUSHIN, P. V., Volnyi, V., & Suslov, K. (2025) · Applied Sciences · doi:10.3390/app152010970 · Cited by 9
Model Predictive Self-healing Control Scheme for Dual Active Bridge Converter
Hosseinzadehtaher, M., Khan, A., Baker, M., & Shadmand, M. B. (2019) · International Conference on Smart Grid and Renewable Energy (SGRE) · doi:10.1109/sgre46976.2019.9020930 · Cited by 9
“In [6], the voltage and power balance control of a DAB based solid state transformer (SST) is studied, a PI controller is used for regulating output side low dc bus voltage and adjusting the phase shift between the primary and secondary side’s voltages of the high-frequency transformer.”
MethodVoltage balancing in DC link capacitor for seven level cascaded multilevel inverter
Yahaya, J. A.-F., & Mansor, M. (2013) · IEEE Conference on Clean Energy and Technology (CEAT) · doi:10.1109/ceat.2013.6775649 · Cited by 8
“This follows to another research paper that had found the main reasons for unbalance DC link: capacitor leakage current, switches, wires, and diodes [6].”
BackgroundStability analysis and control for power electronic transformer with FRT capability
Wang, Z., Yin, X., Chen, Y., & Lai, J. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.107956 · Cited by 8
Prabowo, Y., Sharma, S., Bhattacharya, S., Tripathi, A., & Bhavaraju, V. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3229223 · Cited by 1
“With this input voltage, the DABs are controlled to maintain the output bus voltage ( V O = 950 V) and also to achieve equal current sharing between the (AFE + DAB) cells [24].”
BackgroundInfluentialSelf-citationGangatharan, S., Vidhyaa, K., Anitha, E. A. M., Kumar, B. A., & Vairaprakash, P. (2016) · International Conference on Circuit, Power and Computing Technologies · doi:10.1109/iccpct.2016.7530378 · Cited by 8
Amini, J., & Moallem, M. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793653 · Cited by 8
“To solve previously mentioned defects, certain DC voltage balancing methods have been proposed that use switching redundancy to keep the DC voltages balanced [13-18].”
MethodResearch on the System and Control Strategy of an AC-DC Hybrid Single-Phase Electric Energy Router
Zhao, G., Jiang, C., & Liu, J. (2019) · Electronics · doi:10.3390/electronics8090970 · Cited by 8
“Some studies [12,13] adopted a H-bridge cascade structure, while other studies [14,15] adopted a modular structure.”
Sliding mode control of an ozone generator based on dual AC/DC/AC power converters
Alsmadi, Y. M., Chaírez, I., & Utkin, V. I. (2020) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/0959651820954578 · Cited by 8
“), which have motivated the design of complex control methods based on the application of nonlinear theories, including sliding modes.(13,14) In fact, the realization of sliding mode controllers agrees with the switching nature of power converters.”
MethodJi, Z., Zhao, J., Sun, Y., Yao, X., & Zhu, Z. (2014) · Journal of Power Electronics · doi:10.6113/jpe.2014.14.5.946 · Cited by 8
“INTRODUCTION CHB converters have become an important topic of research in the application domain of large-capacity grid connections for renewable energy and large-capacity energy storage systems [1]-[3].”
BackgroundDesign and construction of a DAB using SiC MOSFETs with an isolation of 24 kV for PET applications
Saeed, M., Rogina, M. R., Lopez, M., Rodríguez, A., Arias, M., & Briz, F. (2017) · European Conference on Power Electronics and Applications · doi:10.23919/epe17ecceeurope.2017.8099160 · Cited by 8
Solid-state transformer-based new traction drive system and control
Feng, J., Shang, J., Zhang, Z., Liu, H., & Huang, Z. (2017) · Frontiers of Mechanical Engineering · doi:10.1007/s11465-018-0467-0 · Cited by 8
Comparative Analysis of CHB and MMC-Based Solid-State Transformer Architectures
França, J. V. G., & Costa, L. F. (2025) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe-powereng63314.2025.11027220 · Cited by 7
“Additionally, the dc-dc converter can handle the voltage balancing in cases where Dual-Active Bridges (DAB) are used [25].”
Prabowo, Y., Sharma, S., Bhattacharya, S., Tripathi, A. K., & Bhavaraju, V. (2022) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9947559 · Cited by 7
“With this input voltage, the DABs are controlled to maintain the output bus voltage (VO = 950 V) and also to achieve equal current sharing between the different (AFE+DAB) cells [17].”
BackgroundSelf-citationStability Analysis of a Medium Voltage Cascaded Converter System with Reduced DC-link Capacitance
Acharya, S., Anurag, A., & Bhattacharya, S. (2019) · Applied Power Electronics Conference · doi:10.1109/apec.2019.8722010 · Cited by 6
“These transformers have many undesirable traits including bulky size, power quality susceptibility, environmental concerns etc [1].”
BackgroundSelf-citationVoltage equalization control of three-phase cascaded H-bridge multilevel rectifiers
Wang, L., Chen, X., Zhang, Z., & Guo, X. (2022) · Journal of Power Electronics · doi:10.1007/s43236-022-00537-4 · Cited by 7
Sharma, S., Prabowo, Y., & Bhattacharya, S. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131314 · Cited by 7
“An H-bridge converter is controlled using a typical vector control strategy [9], and the control structure is shown in Fig.”
BackgroundMethodSelf-citationThe application and challenge of energy router in energy internet
Huang, J., Han, W., Tian, H., Qiu, J., & Chan, C. C. (2024) · Energy internet. · doi:10.1049/ein2.12006 · Cited by 7
Adamowicz, M. (2014) · Acta Energetica Power Engineering Quarterly · doi:10.12736/issn.2300-3022.2014401 · Cited by 7
“There are three main reasons for this rapid development of power electronic devices: • growing demand from the industry and power sectors [2, 3] • increasing level of the technological development of semiconductor and magnetic materials [4–8] • development of microprocessor technology, particularly the engineering of…”
BackgroundMethodModelling, Design and Control of Cascaded H-Bridge Single Phase Rectifier
Kadandani, N. B., Ethni, S., Dahidah, M., & Khalfalla, H. (2019) · International Renewable Energy Congress · doi:10.1109/irec.2019.8754627 · Cited by 7
“Several approaches have been proposed to address this issue [10-20].”
BackgroundThe Current-Shaping Modular Multi-Level DC/DC Converter
Gray, P. A., & Lehn, P. W. (2019) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2019-ecceasia42246.2019.8797053 · Cited by 8
A problem oriented model for teaching power electronic circuits
Jiang, W. Y., Yu, F., & Mo, Y. (2013) · IEEE International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2013.6527004 · Cited by 7
Lingyu, X., Sha, D., & Chen, H. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953724 · Cited by 7
“IGBTs can be used to undergo the voltage of the high voltage side (HVS) [1].”
BackgroundCoordinating voltage regulation for an AC–DC hybrid distribution network with multiple SSTs
Liu, X., Liu, Y., Liu, J., & Zhang, X. (2018) · The Journal of Engineering · doi:10.1049/joe.2018.8537 · Cited by 8
Analysis of Maximum Load Unbalancing Limits of Cascaded H-Bridge Rectifier Under Unity Power Factor
Gao, Z., Wang, C., Fu, J., He, B., Chen, F., & Lu, Q. (2019) · IEEE Access · doi:10.1109/access.2019.2931070 · Cited by 7
“The control algorithm adopted the method in [18] and was programmed in DSP TMS320F28335.”
InfluentialDecentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration
Dutta, S., Lu, M., Mallik, R., Majmunović, B., Mukherjee, S., Seo, G., Maksimović, D., & Johnson, B. (2020) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel49091.2020.9265657 · Cited by 7
Overloading Scenario in Solid State Transformer
Kadandani, N. B., Dahidah, M., Ethni, S., & Alharbi, M. A. (2020) · International Renewable Energy Congress · doi:10.1109/irec48820.2020.9310446 · Cited by 7
“B. Isolation DAB Control Block A controller is required to ensure equal power transfer between the two converters that form the DAB converter.”
BackgroundInfluentialModular Medium Voltage AC to Low Voltage DC Converter for Extreme Fast Charging ApplicationsPreprint
Awal, M. A., Husain, I., Bipu, M. R. H., Bipu, M. R. H., Montes, O. A., Teng, F., Feng, H., Khan, M. A., & Lukic, S. M. (2020) · arXiv (Cornell University) · doi:10.13140/rg.2.2.26685.90082 · Cited by 7
A Highly Modular Interphase Solid-State Transformer Architecture
França, J. V. G., Costa, L. F., & Papafotiou, G. A. (2025) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce58356.2025.11259843 · Cited by 6
Efficiency Improvement of DAB Converters with Enhanced Inductor Current Classification
Xiao, Z., Zhang, L., He, Z., & Tang, Y. K. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362300 · Cited by 6
“…features galvanic isolation, soft switching capability, wide voltage gain range, high power density, and bidirectional power flow ability [1]-[5], and has been widely applied to energy storage systems [4], micro-grids [5]-[7], automation application [8], [9], and solid-state transformer [10]-[12].”
BackgroundYousefpoor, N., Parkhideh, B., Azidehak, A., & Bhattacharya, S. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953801 · Cited by 8
“This solution is often called Solid-State Transformer (SST), [12-17].”
BackgroundSelf-citationOperation method for input‐series‐output‐parallel AC–DC–DC converter
Song, C., Guo, Y., Zeng, Z., Sun, L., He, J., & Li, M. (2016) · IET Power Electronics · doi:10.1049/iet-pel.2015.0592 · Cited by 6
Han, P., He, X., Zhao, Z., Yu, H., Wang, Y., Xu, P., & Shu, Z. (2019) · Journal of Power Electronics · doi:10.6113/jpe.2019.19.1.99 · Cited by 6
Zang, J., Wang, J., Zhang, J., Zhou, J., Shi, G., Feng, X., & Zhang, Y. (2023) · IET Power Electronics · doi:10.1049/pel2.12463 · Cited by 6
Behera, P. K., Pandey, D. C., & Pattnaik, M. (2023) · IEEE International Conference on Smart Technologies for Power, Energy and Control (STPEC) · doi:10.1109/stpec59253.2023.10430829 · Cited by 6
“These applications include microgrids [2], solid-state transformers (SSTs) [3], [4], automotive applications [5], and energy storage systems (ESS) [6].”
BackgroundSarkar, S., & Das, A. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3386726 · Cited by 6
“Usually, when it comes to converting MVDC to dc link voltage of traction inverter, the commonly employed power converter is the isolated input-series output-parallel (ISOP) converter [3], [6], [10], [11].”
Development of power electronic distribution transformer using fuzzy logic control
Ahmed, E. A. (2018) · International Journal of ADVANCED AND APPLIED SCIENCES · doi:10.21833/ijaas.2018.05.004 · Cited by 4
“The second approach is based on the DC link which has many attractive features as used in this project (Zhao et al., 2013; Zhang et al., 2014; Madhusoodhanan et al., 2015, Ahmed et al., 2017).”
MethodA Reconfigurable Multilevel Dual-Active-Bridge Converter for Wide-Range High-Efficiency Operation
Chan, Y. P., Yaqoob, M., Wong, C. S., & Loo, K. H. (2019) · European Conference on Power Electronics and Applications · doi:10.23919/epe.2019.8915005 · Cited by 6
“Introduction In recent years, bidirectional dc-dc power conversion has become an important feature of many modern power electronics systems, such as distributed energy storage systems [1], vehicle-to-grid (V2G) systems [2], and solid state transformers [3].”
BackgroundCarrier Redistribution Pulsewidth Modulation for Five-Level Stacked Multicell Converter
Cheng, Q., Wang, C., & Chen, Z. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3124037 · Cited by 6
“Numerous topologies, including diode-clamping converter [4], [5], cascaded H-bridge converter [6], [7], flying-capacitor converter (FCC) [8], [9], modular multilevel converter (MMC) [10], [11], active neutral-pointclamped converter (ANPC) [12], [13], and stacked multicell”
BackgroundUnruh, R., Lange, J. H., Schafmeister, F., & Böcker, J. (2021) · European Conference on Power Electronics and Applications · doi:10.23919/epe21ecceeurope50061.2021.9570542 · Cited by 8
Liu, H., Ma, L., Song, W., Zhu, J., & Lin, P. (2023) · IET Power Electronics · doi:10.1049/pel2.12454 · Cited by 6
Electronic power transformer to secure the power supply of a mission critical microgrid
Wang, D., Mao, C., Lu, J., & Lee, W. (2014) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2014.6978383 · Cited by 6
“Electronic power transformer (EPT), also known as solid state transformer (SST) [5][6], is a static device that transfers electrical energy from one circuit to another through mediumor high-frequency (MF or HF) electromagnetic inductionbased transformation and power electronic conversion technology [7].”
BackgroundSun, Y., Liu, J., Li, Y., Fu, C., & Wang, H. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512608 · Cited by 6
“One is high frequency modulation, such as Carrier Phase-Shift(CPS) method[6,7], which has agreeable quality of waveform and balanced switch distribution but relatively high switching loss, and requires multiple high-frequency triangular carrier with precise phase shift.”
BackgroundAlam, K. S., Tria, L. A. R., Zhang, D., Xiao, D., & Rahman, M. F. (2017) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2017.8056068 · Cited by 6
Yun, H.-J., Kim, H.-S., Kim, M., Baek, J.-W., & Kim, H. (2018) · Energies · doi:10.3390/en11040928 · Cited by 7
Solid-State Transformers for Distribution Systems: Technology, Performance, and Challenges
Saleh, S., Richard, C., St-Onge, X. F., McDonald, K., Ozkop, E., Chang, L., & Alsayid, B. (2019) · IEEE/IAS Industrial and Commercial Power Systems Technical Conference · doi:10.1109/icps.2019.8733360 · Cited by 4
“Core-type power transformers have shown significant abilities to provide voltage matching, points-of-connection to the grounding system, isolation between the grid and its loads, and bi-directional power flows [1]–[11], [43]–[45].”
BackgroundInfluentialDouble Active Bridge Operated in Quasi Discontinuous Conduction Mode
Vázquez, N., Zhu, R., & Liserre, M. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8926927 · Cited by 6
Design Considerations of Series-Connected Devices Based LLC Converter
Yoon, D., Lee, S.-M., & Cho, Y. (2020) · Energies · doi:10.3390/en13010264 · Cited by 5
Zaid, M. M., & Ro, J. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2019.1389 · Cited by 6
López-Rodríguez, K., Mejía, A. E., Piedrahita-Echavarria, E. Y., & Gil-González, W. (2020) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg48541.2020.9244412 · Cited by 6
“This modulation method is applied on either side of the converter by fixing one bridge and lagging or leading the commutation of the other according to the power flow direction [12], [13].”
MethodSolid state transformer control aspects for various smart grid scenarios
Gorla, N. B. Y., Kolluri, S., & Panda, S. K. (2017) · 2017 IEEE Innovative Smart Grid Technologies - Asia (ISGT-Asia) · doi:10.1109/isgt-asia.2017.8378443 · Cited by 5
A Delay-Free Decoupling Method for FPGA-Based Real-Time Simulation of Power Electronic Systems
Yang, Y., Xu, J., Wang, K., Wu, P., Li, Z., & Li, G. (2024) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2024.3481270 · Cited by 5
“However, as the demand for greater flexibility and efficiency rises, the switching frequency increases steadily [4], [5], [6], [7] and the topology grows more intricate [8], [9], [10].”
A simple modular active power electronic transformer
Roasto, I., & Strzelecki, R. (2014) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2014.6864919 · Cited by 5
Unruh, R., Böcker, J., & Schafmeister, F. (2023) · European Conference on Power Electronics and Applications · doi:10.23919/epe23ecceeurope58414.2023.10264313 · Cited by 6
Nayak, G., & Dasgupta, A. (2024) · IEEE Access · doi:10.1109/access.2024.3376386 · Cited by 5
“The corresponding dynamic equations are [14], where, x d , x q are the d -axis, q -axis components of the variable x , and x ∈ (cid:2) v g , i g , d n (cid”
BackgroundMethodInfluentialZhang, Y., Li, F., Chang, L., & Zhang, X. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3410708 · Cited by 5
“This section aims to further optimize the R vch proposed in Section III based on the characteristics of the typical control-based method for dc-link voltage balance [25], with the objective of enhancing the effectiveness of dc-link voltage balancing control during the startup process.”
MethodNayak, G., & Dasgupta, A. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3477474 · Cited by 5
“This is where it was found to be completely different from ISOP based SSTs where the active component of duty cycle is modified to achieve the control objective [32].”
AC-AC modular multilevel converter applied to solid-state transformers
Oliveira, S. V. G., Castellani, D. G., de Novaes, Y. R., Cardoso, N. P., da Rosa, M. B., Brandt, E. G., & Pires, Y. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7048651 · Cited by 5
“Other studies present the need for connection with renewable energy resources allowing a future application for rural consumers [14], [15].”
BackgroundRodriguez, L. A. G., Balda, J. C., Mallela, A., & Mejía, A. E. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310508 · Cited by 6
“Complex voltage balance control methods are required to keep the dclink voltage in the H-bridges constant [9], [10].”
BackgroundAnalysis of the Internal Electrical Characteristics of Electronic Power Transformers
Yang, Y., Mao, C., Wang, D., & Lu, J. (2013) · Journal of Power Electronics · doi:10.6113/jpe.2013.13.5.746 · Cited by 5
“The electronic power transformer (EPT) is a new form of power transformer that realizes the functions of traditional power transformers and performs power quality functions, such as power factor correction, voltage regulation, voltage sag and swell elimination, voltage flicker reduction, and protection capability, in…”
BackgroundJakka, V. N. S. R., & Shukla, A. (2016) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2016.7695500 · Cited by 5
“PETs have emerged as one of the most predominant methodologies for such applications.”
BackgroundWang, X., Wang, C., & Gu, C. (2019) · Journal of Power Electronics · doi:10.1007/s43236-019-00003-8 · Cited by 5
Mansour, M., Yelaverthi, D. B., & Zane, R. A. (2022) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43599.2022.9773534 · Cited by 5
Improved Operation Strategy for the High Voltage Input Stage of a Multi-Port Smart Transformer
Romero‐Cadaval, E., Barrero‐González, F., González‐Romera, E., Milanés‐Montero, M. I., & Roncero‐Clemente, C. (2022) · Energies · doi:10.3390/en15103778 · Cited by 5
Power Balance Control Scheme for a Cascaded Matrix-Based Dual-Active-Bridge (CMB-DAB) Converter
Saha, J. (2022) · Springer theses · doi:10.1007/978-981-19-4902-9_5 · Cited by 5
Chen, J., Wang, R., Liu, C., & Li, H. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3236101 · Cited by 5
“To make up for these disadvantages, some scholars proposed to balance the capacitor voltage by the improved control [18], [19], but these methods all rely on the voltage sensor to detect the capacitor voltage of each cell.”
BackgroundPower Quality Improvement of the Distribution System using a Solid-State Transformer
Hossain, M. S., Rahman, M. A., Islam, M. R., Sutanto, D., & Muttaqi, K. M. (2022) · IEEE Industrial Electronics Society Annual On-Line Conference (ONCON) · doi:10.1109/oncon56984.2022.10126708 · Cited by 5
“The power electronic-based solid-state transformer has a variety of topologies and control architectures depending on the applications [1], [2].”
BackgroundBipu, M. R. H., Montes, O. A., Lukic, S. M., & Husain, I. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362709 · Cited by 5
“In traditional approach, the SST is controlled by the controller CCon where the AFEs control the voltage of MV DC buses and the DABs control the required power flow to maintain the voltage of the LV DC bus [8], [9].”
MethodFundamental duty modulation of dual-active-bridge converter for universal reduced conduction
Choi, W., & Cho, B. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7309746 · Cited by 5
Zhang, Y., Liu, C., Sun, L. Q., & Zhi, Y. (2016) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec.2016.7779519 · Cited by 5
“Therefore, various control methods for PET are reported and discussed in [3-5], most of which focus on dual-stage control strategy.”
BackgroundMethodXiang, L., Wang, J., Xiaojie, Y., & Wang, K. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854847 · Cited by 5
“INTRODUCTION The cascaded H-bridge (CHB) structure has been widely used for high voltage and high power applications[1-5], of which the cascaded H-bridge rectifier (CHBR) is a typical kind [6-8].”
BackgroundRogina, M. R., Rodríguez, A., Vázquez, A., Lamar, D. G., & Hernando, M. M. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341328 · Cited by 5
Solid state transformer parallel operation with a tap changing line frequency transformer
Fernando, N., Meegahapola, L. G., & Thilakarathne, C. (2017) · IEEE Innovative Smart Grid Technologies-Asia · doi:10.1109/isgt-asia.2017.8378448 · Cited by 5
“control of both the grid side inverter and the front end rectifier [11].”
BackgroundInfluentialJiang, W., Song, W., Ma, J., & Bi, L. (2018) · IEEE International Power Electronics and Application Conference and Exposition (PEAC) · doi:10.1109/peac.2018.8590238 · Cited by 5
“INTRODUCTION As one of the multilevel converter topologies, the cascaded H-bridge (CHB) rectifier has gained an appreciation over years and been used in the power electronic transformer (PET) owning to its modularity and extendibility [1].”
BackgroundAn AC–AC Modular Multilevel Converter-Based Partially Rated Solid-State Transformer
Yang, Q., & Saeedifard, M. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2894639 · Cited by 5
Rong, J., Ai, X., Li, Y., & Ren, D. (2019) · Applied Sciences · doi:10.3390/app9040727 · Cited by 5
Afshari, E., & Amirabadi, M. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8722056 · Cited by 5
“Different technologies have been introduced for SSTs; a major category of them is based on dc-link converters, such as cascaded H-bridge multilevel converters [8, 9].”
MethodVoltage Balance Switching Scheme for Series-Connected SiC MOSFET LLC Resonant Converter
Cha, H.-R., & Kim, R.-Y. (2019) · Energies · doi:10.3390/en12204003 · Cited by 6
Liu, X., Liang, X. P., Gong, K., An, S., Xu, P., Cai, J., Zhu, X., & Zhou, C. (2022) · Journal of Power Electronics · doi:10.1007/s43236-022-00445-7 · Cited by 5
“In [10, 11], to balance the DC-port voltage when the loads of all the submodules are unequal, a PI controller is designed to regulate the modulation depth for each of the submodules.”
BackgroundPark, D.-H., Tahir, H., Lee, J.-D., & Kim, R.-Y. (2022) · IEEE Access · doi:10.1109/access.2022.3175488 · Cited by 5
“The cascaded H-bridge (CHB), which is a representative topology among modular isolation architectures, has been widely used because it can employ the control method applied to the two-level converter [5]-[6].”
MethodA DC-DC Modular Multilevel Converter Topology with Single Arm for MVDC Railway Application
Sarkar, S., & Das, A. (2023) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie51358.2023.10227946 · Cited by 5
“These rail traction applications require a few mega-watts of power and with the new MVDC system; the possible converter topologies are input-series output-parallel (ISOP) topologies [5], [7], [11] and modular multilevel converter topologies [12]–[15].”
BackgroundA Simple Control Method without Voltage Balance Algorithm for Modular Solid-State Transformer
Jang, P., Park, H.-P., Baek, J., Kim, D.-U., & Kim, S. (2022) · 2022 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9948182 · Cited by 4
“4 shows the block diagram of the control scheme in [5].”
BackgroundDesign and control of power electronic transformer with power factor correction
Maheswari, M., & Kumar, N. (2015) · International Conference on Circuit, Power and Computing Technologies · doi:10.1109/iccpct.2015.7159442 · Cited by 4
“…transformer to the power system, first the low frequency power is converted into high frequency power by the power electronic converter and this high frequency voltage is given to the high frequency transformer and again a power converter will step down this high frequency to the desired frequency.”
BackgroundLevel-phase-shifted pulse-width modulation for cascaded H-bridges
Korhonen, J., Järvisalo, H., Jäppinen, J., & Silventoinen, P. (2022) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon49645.2022.9968448 · Cited by 4
“Since, the application range has vastly increased with the applications like static synchronous compensator (STATCOM) and solid state transformers [2], [3], [4], [5].”
BackgroundLi, J., Wu, J., & Xiong, F. B. (2024) · Energies · doi:10.3390/en17051096 · Cited by 5
Choi, C.-W., Ko, J.-S., Yoon, K.-Y., Park, Y.-W., Kang, Y.-S., & Kim, D.-K. (2025) · Energies · doi:10.3390/en18051043 · Cited by 4
Three-phase AC-DC solid-state transformer for low-voltage DC power distribution applications
Joca, D. R., Barreto, L. H. S. C., Oliveira, D. S., & Pacheco, J. D. O. (2016) · IEEE International Conference on Industry Applications · doi:10.1109/induscon.2016.7874536 · Cited by 5
“The control system is responsible for the accurate dynamic and steadystate operation according to the power distribution grid profile [3-8].”
Method
Metadata
- Authors
- Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q.
- Affiliations
- Eaton (United States) (US)
- North Carolina State University (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-04
- Volume
- 28
- Issue
- 4
- Pages
- 1523-1532
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1999302015
- Cited by
- 642
- References
- 22
- Citations by year
- 2026: 23 · 2025: 41 · 2024: 51 · 2023: 47 · 2022: 63 · 2021: 40 · 2020: 59 · 2019: 70 · 2018: 56 · 2017: 63 · 2016: 44 · 2015: 29 · 2014: 37 · 2013: 19
- FWCI
- 17.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- solid-state transformer, cascaded H-bridge converter, dual active bridge converter, DC-link voltage balancing, power balancing, AC-DC rectifier, DC distribution systems, d-q model, power constraints, parallel converter modules
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.