Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Abstract
The solid-state transformer (SST) is an interface device between ac distribution grids and dc distribution systems. The SST consists of a cascaded multilevel ac/dc rectifier stage, a dual active bridge (DAB) converter stage with high-frequency transformers to provide a regulated 400-V dc distribution, and an optional dc/ac stage that can be connected to the 400-V dc bus to provide residential 120/240 V$_{\rm ac}$. However, due to dc-link voltage and power unbalance in the cascaded modules, the unbalanced dc-link voltages and power increase the stress of the semiconductor devices and cause overvoltage or overcurrent issues. This paper proposes a new voltage and power balance control for the cascaded H-Bridge converter-based SST. Based on the single-phase dq model, a novel voltage and the power control strategy is proposed to balance the rectifier capacitor voltages and the real power through parallel DAB modules. Furthermore, the intrinsic power constraints of the cascaded H-Bridge voltage balance control are derived and analyzed. With the proposed control methods, the dc-link voltage and the real power through each module can be balanced. The SST switching model simulation and the prototype experiments are presented to verify the performance of the proposed voltage and power balance controller.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530601 · Cited by 2,665 · cited 1×
“The SST has the features of instantaneous voltage regulation, voltage sag compensation, fault isolation, power factor correction, harmonic isolation, and dc output [1]–[4].”
BackgroundMultilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.502161 · Cited by 2,604
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401 · cited 1×
“The low-voltage dc link is regulated by the DAB converter [16], [19].”
BackgroundResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 1×
“One of the main disadvantages of the cascaded H-bridge rectifier is the voltage unbalance of the dc-link voltages at different H-Bridges [5]–[7], [12], [13], [18], [20].”
BackgroundSelf-citationIndividual Voltage Balancing Strategy for PWM Cascaded H-Bridge Converter-Based STATCOM
Barrena, J. A., Marroyo, L., Rodriguez Vidal, M. Á., & Torrealday Apraiz, J. R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906127 · Cited by 335 · cited 1×
“[8] present an individual voltage-balancing strategy to balance the dc-link voltage with PWM.”
BackgroundA power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
A grid simulator with control of single-phase power converters in D-Q rotating frame
Zhang, R., Cardinal, M., Szczesny, P., & Dame, M. (2003) · 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289) · doi:10.1109/psec.2002.1022377 · Cited by 281 · cited 1×
“The single-phase dq transformation is applied to the (5) and (6) [14], and the differential equations in dq coordinates are Fig.”
MethodA Power Electronic-Based Distribution Transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4312081 · Cited by 264
A Modular Strategy for Control and Voltage Balancing of Cascaded H-Bridge Rectifiers
Iman-Eini, H., Schanen, J.-L., Farhangi, S., & Roudet, J. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002055 · Cited by 205 · cited 1×
“[9] present a method that ensures the dc-link voltages converge to the reference value when load power are different.”
MethodMultilevel intelligent universal transformer for medium voltage applications
Lai, J.-S., Maitra, A., Mansoor, A., & Goodman, F. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518705 · Cited by 185
Cited by
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
A General Review of Multilevel Inverters Based on Main Submodules: Structural Point of View
Vijeh, M., Rezanejad, M., Samadaei, E., & Bertilsson, K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2890649 · Cited by 473
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“The control strategies and balancing circuits are also required to prevent the problem in voltage and power balancing and that comes with drawbacks like complex systems in configuration and control scheme [17], [18].”
BackgroundMethodDesign and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324
Self-citationIslam, M. R., Guo, Y., & Zhu, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2290313 · Cited by 301
“(1) If Vll(rms) is the grid line to line voltage, the minimum dc-link voltage of each H-bridge inverter cell can be calculated from Vdc(min) = √ 2 Vll(rms) (ml − 1) .”
BackgroundVasiladiotis, M., & Rufer, A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2367237 · Cited by 275
“Such converters have been already utilized in railway traction [22]–[24], network coupling, and back-to-back loop power flow control [25], [26], as well as microgrid applications [27], [28].”
Fundamental Duty Modulation of Dual-Active-Bridge Converter for Wide-Range Operation
Choi, W., Rho, K.-M., & Cho, B.-H. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2474135 · Cited by 244
Li, Y., Wang, Y., & Li, B. Q. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2476699 · Cited by 238
High-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC
Zhao, S., Li, Q., Lee, F. C., & Li, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2774440 · Cited by 231
“To date, the cascaded H-bridge multilevel rectifier is deemed as a mature technology and can be directly applied to the proposed DC data center application [5].”
BackgroundGu, C., Zheng, Z., Xu, L., Wang, K., & Li, Y. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2416212 · Cited by 221
“The structure of secondary side dc buses in parallel can drive a single load, however, it is difficult to balance the dc voltages with two or more different loads [22]–[26].”
BackgroundLiu, L., Li, H., Xue, Y., & Liu, W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2333004 · Cited by 212
Review of Dual-Active-Bridge Converters With Topological Modifications
Li, L., Xu, G., Sha, D., Liu, Y., Sun, Y., & Su, M. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3258418 · Cited by 166
“, dc microgrids [1], solid-state transformers (SSTs) [2], automotive applications [3], and energy storage”
BackgroundAn, F., Song, W., Yu, B., & Yang, K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2823364 · Cited by 189
“In order to balance the voltage in CHB stage as well as the power in the DAB stage with circuit parameters mismatch, a voltage and power control scheme is proposed in [7] to balance dc-link capacitor voltages of the adopted CHB converter and the actual transmission power through the parallel DAB converters.”
BackgroundInfluential15 kV SiC MOSFET: An Enabling Technology for Medium Voltage Solid State Transformers
FREEDM Systems Center, N. C. S. U., & Huang, A. Q. (2017) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2017.00012 · Cited by 182
“To avoid power and voltage balancing problems, additional balancing circuits and control strategies are needed [14].”
BackgroundSelf-citationBriz, F., Lopez, M., Rodriguez, A., & Arias, M. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2611648 · Cited by 171
Dual Phase-Shifted Modulation Strategy for the Three-Level Dual Active Bridge DC–DC Converter
Liu, P., Chen, C., Duan, S., & Zhu, W. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2696488 · Cited by 163
“In [13] and [14], a 3.6 kV/10 kW solid-state transformer (SST) system based on 13 kV/10 A SiC MOSFET and junction barrier Schottky (JBS) diode has been developed.”
MethodInfluentialDual-Transformer-Based Asymmetrical Triple-Port Active Bridge (DT-ATAB) Isolated DC–DC Converter
Jakka, V. N. S. R., Shukla, A., & Demetriades, G. D. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674586 · Cited by 160
“Consequently, the powers supplied from the source ports and the output voltage can be regulated by varying D13 and D23 [24].”
BackgroundInfluentialPower electronic technologies for flexible DC distribution grids
Doncker, R. W. D. (2014) · International Power Electronics Conference (IPEC) · doi:10.1109/ipec.2014.6869670 · Cited by 158
Dutta, S., Hazra, S., & Bhattacharya, S. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2551201 · Cited by 165
“These attributes have led to the application of the converter for medium-to-high voltage high power dc-to-dc conversions [8], [9], [28], ac-to-ac conversion [14], [24] as well as for battery storage options for photovoltaic [25] and electric vehicles [7].”
BackgroundSelf-citationMa, D., Chen, W., & Ruan, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2984714 · Cited by 163
“(a) DLVB control strategy for CHB rectifiers [107].”
BackgroundMethodInfluentialZhu, Q., Wang, L., Huang, A. Q., Booth, K., & Zhang, L. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2829174 · Cited by 155
“voltage converters are connected in series to share voltage and power [8]–[14].”
BackgroundSelf-citationA 10-kV/400-V 500-kVA Electronic Power Transformer
Wang, D., Tian, J., Mao, C., Lu, J., Duan, Y., Qiu, J. X., & Cai, H. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2586440 · Cited by 159
“Many researchers have discussed the related topics of the EPT, such as practical topologies [1]–[5], [11]–[15], control strategies [16]–[19], mathematics models [20]–[22], parallel op-”
BackgroundLiu, J., Yang, J., Zhang, J., Zhao, N., & Zheng, Q. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2679489 · Cited by 152
“The intermediate-dc-voltage balance is realized by the CHB converter, while the output current sharing is realized by the DAB converters [16], [17].”
BackgroundDecoupled Control System for Cascaded H-Bridge Multilevel Converter Based STATCOM
Farivar, G. G., Hredzak, B., & Agelidis, V. G. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2472358 · Cited by 145
Ruiz, F., Pérez, M. A., Espinosa, J. R., Gajowik, T., Styński, S., & Malinowski, M. (2020) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2019.2950436 · Cited by 143
A voltage balancing strategy with extended operating region for cascaded H-bridge converters
Moosavi, M., Farivar, G. G., Iman‐Eini, H., & Shekarabi, S. M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2286270 · Cited by 136
“But nonetheless, it is a great advantage for certain applications, such as active rectifiers, where multiple dc sources are provided [11]–[14].”
BackgroundLiu, L., Li, H., Xue, Y. S., & Liu, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304966 · Cited by 131
Taylor, J. A., Dhople, S. V., & Callaway, D. S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.083 · Cited by 121
Solid-State Transformers for Distribution Systems–Part I: Technology and Construction
Saleh, S. A., Richard, C., Onge, X. F. S., McDonald, K. M., Ozkop, E., Chang, L., & Alsayid, B. A. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2923163 · Cited by 119
“Moreover, the capacitors used in these LC filters are manufactured as ceramic capacitors [12], [17], [26],”
BackgroundDesign and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters
Guo, Z., Yu, R., Xu, W., Feng, X., & Huang, A. Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3059879 · Cited by 115
Self-citationA Four-level Hybrid-Clamped Converter With Natural Capacitor Voltage Balancing Ability
Wang, K., Zheng, Z., Xu, L., & Li, Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262834 · Cited by 113
Li, Z., Hsieh, E., Li, Q., & Lee, F. C. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3279030 · Cited by 111
“The authors in [16], [38], and [39] operate the dc–dc converter with dual active bridge (DAB) at tens of kilohertz.”
BackgroundMethodInfluentialDynamic Control and Performance of a Dual-Active-Bridge DC–DC Converter
Takagi, K., & Fujita, H. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2773267 · Cited by 111
“I SOLATED dc–dc converters based on dual-active bridge (DAB) [1]–[3] have been widely studied for bidirectional power conversion applications requiring galvanic isolation and voltage step up/down, such as automobiles [4], [5], battery energy storage systems [6], [7], electric power distribution [8]– [10].”
BackgroundLight-Load Efficiency Enhancement of High-Frequency Dual-Active-Bridge Converter Under SPS Control
Chen, X., Xu, G., Han, H., Liu, D., Sun, Y., & Su, M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3044803 · Cited by 110
“The variations of two bus voltages are small in these DCT applications [3], [4], so single-phase-shift (SPS) control is widely used to obtain simple implementation.”
Kasper, M., Bortis, D., Deboy, G., & Kolar, J. W. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2633334 · Cited by 110
“In [15], a voltage balancing control is presented which is based on modifying the common-duty cycle control (in dq-”
BackgroundMethodPower Electronic Traction Transformer: Efficiency Improvements Under Light-Load Conditions
Besselmann, T., Mester, A., & Dujić, D. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293402 · Cited by 106
“the academic level, with several laboratory-scale prototypes being realized, different topologies being considered, and various grid control features being developed [4]–[15].”
BackgroundWang, X., Liu, J., Ouyang, S., Xu, T., Meng, F., & Song, S. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2434420 · Cited by 108
A Three-Phase Modular Multilevel DC–DC Converter for Power Electronic Transformer Applications
Zhang, J., Wang, Z., & Shao, S. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2609936 · Cited by 105
“sag protection, fault isolation, and dc output [2].”
BackgroundShao, S., Jiang, M., Zhang, J., & Wu, X. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2703902 · Cited by 99
“One common structure is the input-series-outputparallel (ISOP) structure [10]–[15], in which several modules are used to meet the high-voltage high-power requirements.”
BackgroundShadfar, H., Pashakolaei, M. G., & Foroud, A. A. (2021) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12996 · Cited by 99
Sha, D., Xu, G., & Xu, Y. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2696511 · Cited by 98
“(a) Conventional voltage balance control [30] without power flow direction judgment.”
BackgroundMethodInfluentialEnergy Feed-Forward and Direct Feed-Forward Control for Solid-State Transformer
Ge, J., Zhao, Z., Yuan, L., & Lu, T. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2382613 · Cited by 93
A New Resonant Modular Multilevel Step-Down DC–DC Converter with Inherent-Balancing
Zhang, X., Green, T. C., & Junyent‐Ferré, A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2301974 · Cited by 95
“The most promising solution may be converters known as power electronics transformers (PETs) [11], [12], [19], [20].”
BackgroundZhang, L., Sun, K., Li, Y., Lu, X., & Zhao, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2769487 · Cited by 91
A 15-kV class intelligent universal transformer for utility applications
Lai, J., Lai, W.-H., Moon, S., Zhang, L., & Maitra, A. (2016) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2016.7468139 · Cited by 91
Wang, K., Xu, L., Zheng, Z., & Li, Y. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2491779 · Cited by 90
Wang, Y., Li, Y., Cao, Y., Tan, Y., He, L., & Han, J. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.02.048 · Cited by 89
Pugliese, S., Buticchi, G., Mastromauro, R. A., Andresen, M., Liserre, M., & Stasi, S. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2977226 · Cited by 81
“The first voltage balancing strategy is the most used [9], but it usually presents a slower dynamic response due to the low switching frequency at which the CHB is normally operated.”
BackgroundMethodBasu, K., Shahani, A., Sahoo, A. K., & Mohan, N. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320996 · Cited by 84
“Multistage SSTs have the advantage of interfacing with renewable energy sources or storage systems with the available dc link [20].”
BackgroundPerformance Evaluation of Modulation Techniques in Single-Phase Dual Active Bridge Converters
Noroozi, N., Emadi, A., & Narimani, M. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3087418 · Cited by 88
“The DAB converters are also rewarding in high-voltage and high-power applications, where they are used as core cells in cascade or parallel structures [7]–[9].”
BackgroundGao, R., She, X., Husain, I., & Huang, A. Q. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2679679 · Cited by 76
“It is noted that the effective voltage balance and power balance have been demonstrated and reported in [24].”
BackgroundMethodSelf-citationGorla, N. B. Y., Kolluri, S., Chai, M., & Panda, S. K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2918148 · Cited by 76
Multiport Railway Power Conditioner and Its Management Control Strategy With Renewable Energy Access
Ma, F., Wang, X., Deng, L., Zhu, Z. Q., Xu, Q., & Xie, N. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2899138 · Cited by 75
“If power unbalance caused by the parameter deviation is excessive, some issues will happen: 1) thermal stress of switch devices will be uneven, which may make some devices burn out [24] and 2) power unbalance can limit the voltage balance control [22].”
BackgroundSaha, J., Gorla, N. B. Y., Subramaniam, A., & Panda, S. K. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3107500 · Cited by 77
Zheng, G., Chen, Y., & Kang, Y. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3013493 · Cited by 74
“1(a) shows an SST that utilizes a three-phase CHB to withstand MV and uses dual active bridges (DAB) to inject power to or drag power from the H-bridge modules via the MF links [11].”
BackgroundNair, A. C., & Fernandes, B. G. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3038091 · Cited by 72
“The issue of power unbalance in SST is investigated in [24]– [26].”
BackgroundAbu-Siada, A., Budiri, J., & Abdou, A. (2018) · Electronics · doi:10.3390/electronics7110298 · Cited by 69
“In a comparison between MMCs and cascaded H-bridge converters, it was found that, at high voltages (>13.8 kV), MMC arrangement has better efficiency and semiconductor utilisation [55].”
BackgroundInfluentialHarmonics Suppression for Critical Loads Using Electric Springs With Current-Source Inverters
Wang, Q., Cheng, M., & Jiang, Y. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2591942 · Cited by 69
Liu, J., & Zhao, N. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2748032 · Cited by 72
“voltage-balance control and the overall control [20], [21].”
BackgroundGorla, N. B. Y., Kolluri, S., Chai, M., & Panda, S. K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2873201 · Cited by 71
Zhang, J., Liu, J., Zhong, S., Yang, J., Zhao, N., & Zheng, T. Q. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2889107 · Cited by 71
“To get the desired voltage, current and achieve the power balance of the different modules, many control strategies have been studied and presented by many experts and scholars [19], [31], [32].”
BackgroundSaha, J., Gorla, N. B. Y., & Panda, S. K. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3118657 · Cited by 67
“imbalances have been well studied for the two-staged MVac– LVdc conversion, especially in the case of CMSST [12]-[17], the effect of nonidentical submodules has not been investigated”
BackgroundMethodAnalysis and Control of a Novel Modular-Based Energy Router for DC Microgrid Cluster
Tu, C., Xiao, F., Zheng, L. X., Guo, Q., & Shuai, Z. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2878004 · Cited by 67
“Reference [16] points out that the power unbalance range is limited by the ac voltage, dc voltage reference, smoothing inductor, and the H-bridge number.”
BackgroundJafarian, H., Cox, R. W., Enslin, J. H. R., Bhowmik, S., & Parkhideh, B. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2761831 · Cited by 66
Jia, H., Xiao, Q., & He, J. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2834340 · Cited by 63
Hybrid DC–AC Zonal Microgrid Enabled by Solid-State Transformer and Centralized ESD Integration
Agrawal, A., Nalamati, C. S., & Gupta, R. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2899559 · Cited by 63
“In [7] and [12], the modified d–q coordination control is used for SST purpose which still incorporates a high number of PI controllers, hence system stability is at higher risk.”
MethodQi, C., Chen, X., Tu, P., & Wang, P. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2677500 · Cited by 61
“Some of them rely on a combination of multiple proportional-integral (PI) controllers which regulate power flow at each H-bridge [8], [9].”
BackgroundCapacitor Voltage Balancing for Neutral Point Clamped Dual Active Bridge Converters
Awal, M. A., Bipu, M. R. H., Montes, O. A., Feng, H., Husain, I., Yu, W., & Lukic, S. M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2988272 · Cited by 63
“gies, DAB converters are used to achieve multiple isolated dc buses [24].”
MethodMinimum Backflow Power and ZVS Design for Dual-Active-Bridge DC–DC Converters
Xu, F., Liu, J., & Dong, Z. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3156159 · Cited by 59
“1 is used in a variety of power conversion applications such as power electronic transformers [1], [2], electric vehicles [3], [4], smart grids [5]–[7], and energy storage systems [8], [9] due to their desirable features of electrical isolation, high power density, bidirectional energy flow, and easy realization of ze…”
BackgroundLiu, B., Song, W., Li, Y., & Zhan, B. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3012540 · Cited by 59
“1) Conventional Voltage Balancing Method in [20]: The modifications of duty cycles in this method are defined as ⎧⎨ ⎩ Δddi = ( kP + kI s ) (Ucav − Uci) (i = 1, 2, .”
BackgroundMethodInfluentialShi, Y., Liu, B., Shi, Y., & Duan, S. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2442528 · Cited by 58
Li, X., Dong, Z., Cao, Y., Qin, J., Zhang, Z., Tse, C. K., & Wang, R. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3290671 · Cited by 57
“Numerous control schemes have been developed to address the power balancing of series–parallel-connected converters, including two-loop control [21], [22], droop control [23], [24], [25], master–slave control [26], [27], and model-predictive control (MPC) [20], [28], among others [29], [30].”
BackgroundDesign and Implementation of a Two-Stage Grid-Connected High Efficiency Power Load Emulator
Kanaan, H. Y., Caron, M., & Al‐Haddad, K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295023 · Cited by 62
Li, K., Wen, W., Zhao, Z., Yuan, L., Cai, W., Mo, X., & Gao, C. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3036249 · Cited by 58
Yi, Z., Sun, K., Liu, H., Cao, G., & Lu, S. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3094674 · Cited by 56
Review of Solid-State Transformer Applications on Electric Vehicle DC Ultra-Fast Charging Station
Valedsaravi, S., Aroudi, A. E., & Martinez-Salamero, L. (2022) · Energies · doi:10.3390/en15155602 · Cited by 56
A Modular Multilevel Converter With Self-Voltage Balancing Part II: Y-Matrix Modulation
Liu, Y., & Peng, F. Z. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2923576 · Cited by 55
High frequency transformer design for modular power conversion from medium voltage AC to 400V DC
Zhao, S., Li, Q., & Lee, F. C. (2017) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2017.7931108 · Cited by 53
“For the AC/DC stage, a cascaded H-bridge multilevel rectifier will be used to reach desired medium voltage [6].”
MethodPeak Current Control and Feed-Forward Compensation of a DAB Converter
Vázquez, N., & Liserre, M. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2949523 · Cited by 55
Mou, D., Luo, Q., Li, J., Wei, Y., Wang, Z., Sun, P., Du, X., & Mantooth, H. A. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3022416 · Cited by 55
“Accordingly, it has been widely used in many important applications, such as solid-state transformer [2], [3], electric vehicles (EV) [4], [5], and energy storage systems [6] to name a few.”
BackgroundSynchronous Boost Converter With High Efficiency at Light Load Using QSW-ZVS and SiC mosfets
Rodríguez, A., Vázquez, A., Rogina, M. R., & Briz, F. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2716864 · Cited by 55
Briz, F., López, M., Rodríguez, A., Zapico, A., Arias, M., & Reigosa, D. (2015) · IEEE International Conference on Industrial Informatics (INDIN) · doi:10.1109/indin.2015.7281971 · Cited by 51
“4c) [2],[19],[21],[22].”
Sha, D., Qinwu, L., You, F., Wang, X., & Xu, G. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2512225 · Cited by 50
“Insulated gate bipolar transistors (IGBTs) can be used to undergo the voltage stress of the high voltage side (HVS) [1].”
BackgroundA Modular Multilevel Converter With Self-Voltage Balancing Part I: Mathematical Proof
Liu, Y., & Peng, F. Z. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2923582 · Cited by 49
Xu, J. Q., Wang, K., Wu, P., Li, Z., Liu, Y., Li, G., & Zheng, W. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3037233 · Cited by 49
Krishnamoorthy, H. S., Rana, D., Garg, P., Enjeti, P. N., & Pitel, I. J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295419 · Cited by 48
Pugliese, S., Andresen, M., Mastromauro, R. A., Buticchi, G., Stasi, S., & Liserre, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2840961 · Cited by 48
“In particular in [27]–[29], a review of the CHB dc voltage balancing techniques for ST application is presented.”
BackgroundXiang, X. J., Zhang, X., Chaffey, G. P., & Green, T. C. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2735634 · Cited by 47
“quired between different modules would be another drawback in the practical operation although some relevant solutions have been presented [17], [18].”
BackgroundSarkar, S., & Das, A. (2022) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2022.3221006 · Cited by 47
“input dc link and power unbalance of each SIPO module should be addressed due to parameter variation of the high-frequency transformers, such as leakage inductance and turns ratio [14].”
BackgroundTian, J., Mao, C., Wang, D., Nie, S., & Yang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2794558 · Cited by 47
“The detailed descriptions of the phase-shift strategy can be seen in [30], and the ideal waveforms of the MFT are shown in Fig.”
BackgroundRahman, M. A., Islam, M. R., Muttaqi, K. M., & Sutanto, D. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2972507 · Cited by 45
“Mostofthe existingworksonSSThaveconsideredthDABdc–dcconverter astheisolationstage[16]–[19]ofSST,whereasthisarticle considersmultipleactivebridge(MAB)dc–dcconverterforthe isolation stage.”
BackgroundMethodZheng, Z., Gao, Z., Gu, C., Xu, L., Wang, K., & Li, Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2290019 · Cited by 46
“Otherwise, the dc bus on the secondary side must be connected in parallel to keep voltage balance when feeding isolated unbalanced loads [14].”
BackgroundWang, C., Zhang, K., Xiong, J., Xue, Y. S., & Liu, W. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2842789 · Cited by 44
Power-Linked Predictive Control Strategy for Power Electronic Traction Transformer
Zhao, N., Liu, J., Ai, Y., Yang, J., Zhang, J., & You, X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2952914 · Cited by 44
“In [27] and [28], the phase-shift duty of DAB is modified not only based on the current, but also on the dc-link voltage or other control parameters from CHB, as shown in Fig.”
BackgroundHigh-Efficiency Control Strategy for 10-kV/1-MW Solid-State Transformer in PV Application
Liu, T., Yang, X., Chen, W., Xuan, Y., Li, Y., Huang, L., & Hao, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2984685 · Cited by 44
“Numerous topologies have been investigated for this dc–dc converter in SST [3]–[7].”
BackgroundSelf-Healing Predictive Control of Battery System in Naval Power System With Pulsed Power Loads
Hosseinzadehtaher, M., Khan, A., Easley, M., Shadmand, M. B., & Fajri, P. (2020) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2020.3014294 · Cited by 44
“A voltage control with power balancing mechanism is proposed in [11] for solid state transformer (SST) based on parallel DAB modules.”
Reactive Power Minimization for Modular Multi-Active-Bridge Converter With Whole Operating Range
Mou, D., Dai, Y., Yuan, L., Luo, Q., Wang, H., Wei, S., & Zhao, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3264748 · Cited by 44
“To more efficiently and flexibly connect distributed power sources, energy storage and loads, multiport power electronic transformers (PETs) have emerged as a critical power device due to their unique features of multiport, multicascade, multiflow, and multiforms for power routing functions of power transmission path…”
BackgroundDevelopment of Power Electronic Distribution Transformer Based on Adaptive PI Controller
Ahmed, K. Y., Yahaya, N. Z., Asirvadam, V. S., Saad, N. B., Kannan, R., & Ibrahim, O. (2018) · IEEE Access · doi:10.1109/access.2018.2861420 · Cited by 43
“On the other hand, the second approach has better control, a higher power factor, and a lower stress factor [1], [12].”
BackgroundXu, P., He, X., Han, P., Lin, H., Gao, S., & Shu, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2611607 · Cited by 43
“Another rectifier has been developed to control the voltage balancing algorithm by adjusting the duty time of the vector using a proportional integral controller [33].”
MethodJafarian, H., Bhowmik, S., & Parkhideh, B. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714129 · Cited by 43
Metadata
- Authors
- Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q.
- Affiliations
- Eaton (United States) (US)
- North Carolina State University (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-04
- Volume
- 28
- Issue
- 4
- Pages
- 1523-1532
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1999302015
- Cited by
- 642
- References
- 22
- Citations by year
- 2026: 23 · 2025: 41 · 2024: 51 · 2023: 47 · 2022: 63 · 2021: 40 · 2020: 59 · 2019: 70 · 2018: 56 · 2017: 63 · 2016: 44 · 2015: 29 · 2014: 37 · 2013: 19
- FWCI
- 17.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- solid-state transformer, cascaded H-bridge converter, dual active bridge converter, DC-link voltage balancing, power balancing, AC-DC rectifier, DC distribution systems, d-q model, power constraints, parallel converter modules
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.