Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The solid-state transformer (SST) is an interface device between ac distribution grids and dc distribution systems. The SST consists of a cascaded multilevel ac/dc rectifier stage, a dual active bridge (DAB) converter stage with high-frequency transformers to provide a regulated 400-V dc distribution, and an optional dc/ac stage that can be connected to the 400-V dc bus to provide residential 120/240 V$_{\rm ac}$. However, due to dc-link voltage and power unbalance in the cascaded modules, the unbalanced dc-link voltages and power increase the stress of the semiconductor devices and cause overvoltage or overcurrent issues. This paper proposes a new voltage and power balance control for the cascaded H-Bridge converter-based SST. Based on the single-phase dq model, a novel voltage and the power control strategy is proposed to balance the rectifier capacitor voltages and the real power through parallel DAB modules. Furthermore, the intrinsic power constraints of the cascaded H-Bridge voltage balance control are derived and analyzed. With the proposed control methods, the dc-link voltage and the real power through each module can be balanced. The SST switching model simulation and the prototype experiments are presented to verify the performance of the proposed voltage and power balance controller.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530601 · Cited by 2,665 · cited 1×
“The SST has the features of instantaneous voltage regulation, voltage sag compensation, fault isolation, power factor correction, harmonic isolation, and dc output [1]–[4].”
BackgroundMultilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.502161 · Cited by 2,604
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401 · cited 1×
“The low-voltage dc link is regulated by the DAB converter [16], [19].”
BackgroundResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 1×
“One of the main disadvantages of the cascaded H-bridge rectifier is the voltage unbalance of the dc-link voltages at different H-Bridges [5]–[7], [12], [13], [18], [20].”
BackgroundSelf-citationIndividual Voltage Balancing Strategy for PWM Cascaded H-Bridge Converter-Based STATCOM
Barrena, J. A., Marroyo, L., Rodriguez Vidal, M. Á., & Torrealday Apraiz, J. R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906127 · Cited by 335 · cited 1×
“[8] present an individual voltage-balancing strategy to balance the dc-link voltage with PWM.”
BackgroundA power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
A grid simulator with control of single-phase power converters in D-Q rotating frame
Zhang, R., Cardinal, M., Szczesny, P., & Dame, M. (2003) · 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289) · doi:10.1109/psec.2002.1022377 · Cited by 281 · cited 1×
“The single-phase dq transformation is applied to the (5) and (6) [14], and the differential equations in dq coordinates are Fig.”
MethodA Power Electronic-Based Distribution Transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4312081 · Cited by 264
A Modular Strategy for Control and Voltage Balancing of Cascaded H-Bridge Rectifiers
Iman-Eini, H., Schanen, J.-L., Farhangi, S., & Roudet, J. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002055 · Cited by 205 · cited 1×
“[9] present a method that ensures the dc-link voltages converge to the reference value when load power are different.”
MethodMultilevel intelligent universal transformer for medium voltage applications
Lai, J.-S., Maitra, A., Mansoor, A., & Goodman, F. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518705 · Cited by 185
Cited by
Items 601–651 of 651
Li, J., Wu, J., Xiong, F., & Hao, L. (2025) · Electronics · doi:10.3390/electronics14020279
A Three Phase Unfolding Based Solid-State Traction Transformer for Railway Application
Khan, A. F., Nag, S. S., & Singh, B. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861709
A QAB-Based SST DC Charging System for Light Rail Transit Trains
Wang, M., & Lee, T. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861553
Study of Overmodulation of Solid-State Transformer Under Asymmetric Grid Short-Circuit Faults
Zheng, H., Lin, Q., Burgos, R. P., Dong, D., & Li, X. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861646
Research on Abnormal Forward and Reverse Control of H-bridge Drive Circuit
Ji, J., Chen, K., & Huang, K. (2024) · International Conference on Electrical, Mechanical and Computer Engineering (ICEMCE) · doi:10.1109/icemce64157.2024.10862968
“The duty cycle of the PWM signal changes from 0% to 100%, controlling the motor to rotate from low speed to high speed [4~6] .”
Wang, H., Chen, M., Li, G., Zheng, M., & Hu, C. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3543535
“Due to constraints posed by the voltage rating of semiconductor power devices, SSTs that convert medium-voltage ac to low-voltage dc typically adopt an input-series output-parallel structure [5], [6], [7], [8].”
Large-capacity power electronic transformer with low device usage
Hou, B., Li, Y., & Teng, Y. (2025) · Journal of Power Electronics · doi:10.1007/s43236-025-01022-4
Huang, P., Xiang, P., & Dian, R. (2024) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems60997.2024.10921464
“In this paper, the voltage balance on the DC side of the 9 H-bridges is achieved by performing a separate voltage following control for each DAB on the back end [7].”
Analysis of Maximum Power Transfer Limit for Linear Operation of Dual-Active-Bridge Converters
Sarda, R., Rodríguez, E., Liang, G., Farivar, G. G., Pou, J., Vaisambhayana, S., & Tripathi, A. (2025) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48143.2025.10977083
“Notable research has been done on DAB converters with controlled voltage sources and energy storages on either input, output, or both-sides of the converter [4]–[7].”
InfluentialA SYSTEMATIC LITERATURE REVIEW ON ENERGY-EFFICIENT TRANSFORMER DESIGN FOR SMART GRIDSPreprint
Bajwa, A. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5234687 · Cited by 2
Li, H., Hatahet, W., Paull, J. J., Han, J., Wang, L., & Li, W. (2025) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2025.3584585 · Cited by 1
Implementation of Hybrid 3L-NPC-FB CLLC Resonant Converter Applied in MVDC
Hsu, C.-W., Lin, H.-C., & Chen, J.-F. (2025) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias62731.2025.11061510
“As renewable energy sources such as wind and solar become more prevalent, new power electronic technologies are required to ensure stability, efficiency, and reliability in power conversion and transmission systems [1]-[4].”
Control Architecture for Solid-state Transformer with Effective Power Sharing
Mazumder, S., Harisyam, P. V., & Basu, K. (2025) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia63110.2025.11112315
“The control architecture discussed in [6] requires measuring the output voltage and current of any of the H-bridges of DAB and computing the power for each DAB to ensure equal power sharing.”
InfluentialYang, J., Liu, Q., & Peng, P. (2025) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec64805.2025.11116530
A Novel Decentralized Control Architecture for Power Electronic Transformer Application
Mazumder, S., Harisyam, P. V., & Basu, K. (2025) · International Telecommunications Energy Conference (INTELEC) · doi:10.1109/intelec63987.2025.11214776
“Moreover, they either require high-bandwidth sensors [1] or estimation-based algorithms [2], [3] to maintain power balance, which compromises the overall reliability of the control system.”
Li, H., Xu, P., Liu, L., Liu, X., An, S., & Peng, W. (2025) · Journal of Power Electronics · doi:10.1007/s43236-025-01186-z
“In recent years, the multilevel topology of cascaded converters has been widely used in applications, such as power electronic transformers (PET) [1], traction power supply systems [2], and STATCOM [3] due to its compact size, high modularity, low harmonic content, and low switching frequency [4].”
Distributed Control for PV-Fed CHB Converter Under Extreme Mismatch Condition
Fathi, M., & Khajehoddin, S. A. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3636439
“26 shows the required Q g for the proposed method compared to the approaches in [24] and [26], which distribute reactive power equally or inversely to cell active power.”
InfluentialUnruh, R., Böcker, J., & Schafmeister, F. (2025) · Energy Conversion Congress and Expo Europe (ECCE Europe) · doi:10.1109/ecce-europe62795.2025.11238538
Mazumder, S., Harisyam, P. V., & Basu, K. (2025) · Energy Conversion Congress and Expo Europe (ECCE Europe) · doi:10.1109/ecce-europe62795.2025.11238795
“…connected in an input This work was supported in part by the Department of Science and Technology, Government of India, under the project titled ”Medium Voltage Grid Integration of Utility-Scale Renewable” through the Core Research Grant scheme. series output parallel (ISOP) configuration [1].”
InfluentialControl Architecture for Solid-State Transformer with Improved Transient Performance
Mazumder, S., Harisyam, P. V., & Basu, K. (2025) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce58356.2025.11259883
“[1]–[3] present control strategies where CHB regulates intermediate DC bus voltages and grid current, while DAB manages power sharing among the DC-DC converters and the output voltage control.”
Counters Design for OC Switch Fault Diagnosis Conjunct with SVM Concept in CHBMCs
Lin, H., Lin, Z., Xie, D., & Li, Y. (2025) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce58356.2025.11260093
High-frequency Power Conversion for Medium Voltage Power Electronics Interfaces
Li, Z. (2024) · VTechWorks (Virginia Tech) · Cited by 2
Deshmukh, R. S., Rituraj, G., Bauer, P., & Vahedi, H. (2025) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2025.3647490
“Table 1 provides a comparison of prior research on DAB converters with the present study, organized by application [8], [9], [10], [11], [12], [13], [14], [15], [16], [17], [18], [19], [20], [21], [22], [23], [24], [25], [26], [27], [28], [29], [30], [31], [32].”
Structure and Hierarchical Control Method of Battery‐Based Hybrid Power Flow Controller
Shao, H., Zhang, J., Wang, S., Zheng, Z., Zhang, J., & Zhang, M. (2026) · International Transactions on Electrical Energy Systems · doi:10.1155/etep/6984618
Peak Current Control With Feed-Forward Compensation of DAB Under Single Phase-Shift Control
Dong, J., Dong, H., Yao, L., & Pan, S. (2025) · IEEE International Conference on Smart Power and Energy Technologies (SPET) · doi:10.1109/spet67577.2025.11335736
Multirate EMT Simulation of Power Electronic Transformers With High-Precision Firing Signals
Wang, H., Xu, J., & Feng, M. (2026) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2026.3656907
“A typical cascaded H-bridge-type dual active bridge (CHB-DAB) based PET [5] illustrated in Fig.”
Delta-connected series-cascaded microgrids with extended power routing range control
Ali, S., Bogarra, S., Khan, M. M., & Córcoles, F. (2026) · Sustainable Energy Grids and Networks · doi:10.1016/j.segan.2026.102128
Xu, S., Xu, Z., Liu, C., & Wu, D. (2025) · International Conference on Electrical Engineering and Control Science (IC2ECS) · doi:10.1109/ic2ecs68700.2025.11362315
“[4] proposes a power balancing method that achieves power sharing by sampling the inductor current and input voltage of each DAB module in real-time, calculating the actual transmission power of each module, and comparing it with the reference power.”
Hwang, H., Park, S.-J., Kim, M., Lee, J., & Lee, S.-H. (2026) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2026.3661374
“The net DC voltage of the CHB ( N V dc = = 1 V dc _ i ) should be higher than the peak grid voltage [22].”
Lin, J., Xu, B., Luo, K., Chen, B., Wang, Q., & Wang, F. (2025) · IEEE International Power Electronics and Application Symposium (PEAS) · doi:10.1109/peas66638.2025.11403487
“Conventional large-capacity photovoltaic(PV) grid-connected systems based on Low-Frequency Transformers (LFTs) exhibit inherent limitations and fail to meet the new demands of modern power grids[1].”
Srinivas, G., Chaitanya, B., Sri, S. J., Vani, G. A., Kumar, M. U., & Vishnu, K. (2025) · International Conference on Recent Trends in Electrical, Electronics and Computing Technologies (ICRTEECT) · doi:10.1109/icrteect67512.2025.11448652
SOC-Correlated Power Balancing Strategy for Independent-Input Parallel-Output Systems
Xu, M., Liu, Z., Tian, J., Ning, D., & Yang, G. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-981-95-7334-9_63
Sarda, R., Rodríguez, E., Farivar, G. G., Gorla, N. B. Y., Pou, J., & Ghias, A. M. Y. M. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2026.3677627
“In the conventional control scheme, Stage I regulates the sum of the HV DC-link capacitor energies (or voltages), while Stage II manages the energy (or voltage) of the LV DC-link capacitor [14], [15], [16], [17].”
Khan, A., Nag, S. S., & Singh, B. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3698789
Multiport Electrical Energy Routing Technology for Vehicle-Grid Interaction in Integrated Microgrid
Qu, D., Yao, D., & Chen, Z. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-981-95-9342-2_45
Buck–Boost ZVqZCS Control for DAB Converters in 7.2 kW GaN-Based OBC Applications
Jalalabadi, E., Jiao, Y., Lu, L., & Wang, X. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3706434
“…(DAB) converters have gained significant attention as an effective topology for medium to high-power applications, particularly in scenarios that require galvanic isolation, such as DC microgrids, solid-state transformers [1], electrical vehicle power supply [2], and energy storage solutions [3].”
Zhang, J., Wen, C., Wang, D., Chen, Y., Liu, S., Gao, T., & Li, X. (2026) · Electronics · doi:10.3390/electronics15132839 · Cited by 2
Optimized Second-Harmonic Control Strategy in Solid-State Transformers
Feng, C., Zheng, Z., Li, C., Wang, C., & Chen, H. (2026) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec69682.2026.11572359
“Zhao et al. [2] and Wang et al. [3] proposed a control method that precisely regulates DC-DC stages to eliminate power fluctuations at twice the grid frequency, effectively functioning as a constant power source.”
Wang, M. C., Xie, D., Xi, H., & Ge, X. (2026) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec69682.2026.11571863
“As a pivotal component of the power electronic transformer (PET), the cascaded H-bridge rectifier (CHBR) is widely favored for its modularity [1]-[3].”
Han, B. (2026) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec69682.2026.11572538
“In a three-phase star-connected configuration, inconsistencies in circuit parameters—such as variations in capacitance, transformer leakage inductance, and switching device characteristics—are inevitable due to manufacturing tolerances and aging [4].”
Design and Evaluation of a Control Scheme for the Single-Phase Solid-State Transformer
Pan, Y.-H., Su, Y.-C., Nguyen, H.-Q., & Yu, M.-H. (2026) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-nagasaki2026-ec64663.2026.11597186
“In this paper, the control mechanism follows the dual-layer voltage control strategy for the CHB converter as described in [9].”
Assessment of Transformer Mismatch in LLC-Based Two-Stage Solid-State Transformers
Queiroz, S. S., França, J. V. G., & Costa, L. F. (2026) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-nagasaki2026-ec64663.2026.11597226
“Alternatively, the ac/dc stage can be implemented using a cascaded H-bridge (CHB) converter in an ISOP arrangement, in which each H-bridge module processes a portion of the MVAC voltage and generates an individual dc link that feeds a dedicated isolated dc/dc converter [7], [8].”
Zheng, Y., Li, X. W., Yan, J., Hao, S., Liu, A., & Ma, X. Y. (2026) · International Conference on Energy Systems and Electrical Power (ICESEP) · doi:10.1109/icesep70386.2026.11607956
“Compared with single-stage AC-DC MMCs, the flexible interconnective SST (hereafter referred to as FI-SST) involves multi-staged converter control, which significantly increases system complexity[11].”
Zheng, Y., Xu, Y., Zhou, Z., Weng, D., He, P., & Xuan, Y. (2026) · International Conference on Energy Systems and Electrical Power (ICESEP) · doi:10.1109/icesep70386.2026.11607864
Modelling and Closed-Loop Control of Half-Bridge Active Clamp Current-Fed DC/DC Converter
Yan, X., Yang, T., Wang, K., & Bozhko, S. V. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3728641
Cui, W., Chen, P., Xu, B., Gan, Z., Liu, Y., & Zhang, G. (2026) · Energies · doi:10.3390/en19174046
A Novel Dual Gun High Power EV Charging Solution with Modular Dual-Transformer Quad-Active-Bridges
Sahu, S., De, D., Patra, A. K., Dunna, V. K., Baghasingh, B., Harikrishnana, A., Goel, V., Narayanan, R., & Davis, T. (2026) · IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET) · doi:10.1109/sefet69291.2026.11687639
“Finally, the modulating signal is scaled by the fraction calculated on the basis of the different DC-bus related voltage to maintain each DC-bus voltage to their respective set point [14].”
Katı hal transformatörü için yeni bir doğrusal tabanlı kapalı çevrim kontrol yöntemi ve uygulaması
Cavdar, M. (2025) · Yildiz Technical University - AVESIS
Ali, S., Bogarra, S., Khan, M. M., & Córcoles, F. (2026) · Electric Power Systems Research · doi:10.1016/j.epsr.2026.114393
Younis, E. A., Ghazal, O., Soliman, M., Jain, A., Zayed, O., Abuelnaga, A. H., & Narimani, M. (2026) · Energy Conversion Congress and Expo Europe (ECCE Europe) · doi:10.1109/ecceeurope67962.2026.11738309
“To address this, cell-level balancing controllers introduce small duty-cycle offsets to compensate for power mismatches and maintain uniform DC-link voltages [5].”
Influential
Metadata
- Authors
- Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q.
- Affiliations
- Eaton (United States) (US)
- North Carolina State University (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-04
- Volume
- 28
- Issue
- 4
- Pages
- 1523-1532
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1999302015
- Cited by
- 642
- References
- 22
- Citations by year
- 2026: 23 · 2025: 41 · 2024: 51 · 2023: 47 · 2022: 63 · 2021: 40 · 2020: 59 · 2019: 70 · 2018: 56 · 2017: 63 · 2016: 44 · 2015: 29 · 2014: 37 · 2013: 19
- FWCI
- 17.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- solid-state transformer, cascaded H-bridge converter, dual active bridge converter, DC-link voltage balancing, power balancing, AC-DC rectifier, DC distribution systems, d-q model, power constraints, parallel converter modules
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.