Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The solid-state transformer (SST) is an interface device between ac distribution grids and dc distribution systems. The SST consists of a cascaded multilevel ac/dc rectifier stage, a dual active bridge (DAB) converter stage with high-frequency transformers to provide a regulated 400-V dc distribution, and an optional dc/ac stage that can be connected to the 400-V dc bus to provide residential 120/240 V$_{\rm ac}$. However, due to dc-link voltage and power unbalance in the cascaded modules, the unbalanced dc-link voltages and power increase the stress of the semiconductor devices and cause overvoltage or overcurrent issues. This paper proposes a new voltage and power balance control for the cascaded H-Bridge converter-based SST. Based on the single-phase dq model, a novel voltage and the power control strategy is proposed to balance the rectifier capacitor voltages and the real power through parallel DAB modules. Furthermore, the intrinsic power constraints of the cascaded H-Bridge voltage balance control are derived and analyzed. With the proposed control methods, the dc-link voltage and the real power through each module can be balanced. The SST switching model simulation and the prototype experiments are presented to verify the performance of the proposed voltage and power balance controller.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530601 · Cited by 2,665 · cited 1×
“The SST has the features of instantaneous voltage regulation, voltage sag compensation, fault isolation, power factor correction, harmonic isolation, and dc output [1]–[4].”
BackgroundMultilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.502161 · Cited by 2,604
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401 · cited 1×
“The low-voltage dc link is regulated by the DAB converter [16], [19].”
BackgroundResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 1×
“One of the main disadvantages of the cascaded H-bridge rectifier is the voltage unbalance of the dc-link voltages at different H-Bridges [5]–[7], [12], [13], [18], [20].”
BackgroundSelf-citationIndividual Voltage Balancing Strategy for PWM Cascaded H-Bridge Converter-Based STATCOM
Barrena, J. A., Marroyo, L., Rodriguez Vidal, M. Á., & Torrealday Apraiz, J. R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906127 · Cited by 335 · cited 1×
“[8] present an individual voltage-balancing strategy to balance the dc-link voltage with PWM.”
BackgroundA power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
A grid simulator with control of single-phase power converters in D-Q rotating frame
Zhang, R., Cardinal, M., Szczesny, P., & Dame, M. (2003) · 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289) · doi:10.1109/psec.2002.1022377 · Cited by 281 · cited 1×
“The single-phase dq transformation is applied to the (5) and (6) [14], and the differential equations in dq coordinates are Fig.”
MethodA Power Electronic-Based Distribution Transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4312081 · Cited by 264
A Modular Strategy for Control and Voltage Balancing of Cascaded H-Bridge Rectifiers
Iman-Eini, H., Schanen, J.-L., Farhangi, S., & Roudet, J. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002055 · Cited by 205 · cited 1×
“[9] present a method that ensures the dc-link voltages converge to the reference value when load power are different.”
MethodMultilevel intelligent universal transformer for medium voltage applications
Lai, J.-S., Maitra, A., Mansoor, A., & Goodman, F. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518705 · Cited by 185
Cited by
Items 201–300 of 651
Zheng, L., Kandula, R. P., & Divan, D. M. (2020) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec39645.2020.9124346 · Cited by 20
“INTRODUCTION With increased need of integrating more intermittent sources and loads – renewable energy and electric vehicles into the grid, solid-state transformer (SST) is considered as an attractive solution to replace the conventional low-frequency transformer for more controllability – providing sources/loads inte…”
BackgroundXiong, L., Gui, Y., Liu, H., Yang, W., & Gong, J. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341559 · Cited by 19
“Modulation Compensation The modulation compensation method is derived from [10] to ensure the dc voltage of PV cells follow their MPPTs.”
MethodOptimal integration of DER and SST in active distribution networks
Meng, F., Chowdhury, B., & Hossan, M. S. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.07.035 · Cited by 19
“SSTs are also able to control voltage and power balance for higher energy efficiency [12,13].”
BackgroundHe, X., Yu, H., Han, P., Zhao, Z., Xu, P., Shu, Z., Koh, L. H., & Wang, P. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2984193 · Cited by 19
“intermodule voltage balancing when loads of each module are greatly unequal [24].”
BackgroundDecoupling Control of Cascaded Power Electronic Transformer Based on Feedback Exact Linearization
Sun, Y., Zhu, J., Fu, C., & Chen, Z. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3069208 · Cited by 20
Bidirectional Solid-State Circuit Breaker Using Super Cascode for MV SST and Energy Storage Systems
Mehrotra, U., Ballard, B., & Hopkins, D. C. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3081684 · Cited by 20
General High-Frequency-Link Analysis and Application of Dual Active Bridge Converters
Xiao, Z., He, Z., Wang, H., Luo, A., Shuai, Z., & Guerrero, J. M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2963746 · Cited by 19
“With the development of power electronics, DC-DC converters like phase shift full bridge converters (PSFB), resonant or multi-resonant converters, and dual active bridge converters (DAB) are widely adopted in battery charger [10]-[12][13], automotive application [13]-[16], solid-state transformer [17]-[22], photovolta…”
BackgroundDual active bridge synchronous chopper control strategy in electronic power transformer
Zhang, R., Wang, D., Mao, C., Lu, J., Yang, J., Yang, Y., Chen, X., & Zhang, J. (2014) · IET Electric Power Applications · doi:10.1049/iet-epa.2013.0181 · Cited by 18
An overview on energy router based on various forms of energy
Zhou, X., Wang, F., Ma, Y., Gao, Z., Wu, Y., Yin, J., & Xu, X. (2016) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc.2016.7531478 · Cited by 19
Decomposed Discrete-Time Model and Multiscale Oscillations Analysis of the DAB Converter
Gao, G., Lei, W., Tang, Q., Xiao, Z., Hu, X., & Wang, Y. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2970039 · Cited by 19
“As a pivotal interface, the DAB converters are also widely applied to the solid-state transformers [8], [9], electric or hybrid vehicles [10]–[13] and the uninterruptible power supplies [14].”
BackgroundPower Balance Control of Cascaded Matrix-Based Dual-Active-Bridge Converter
Saha, J., Gorla, N. B. Y., & Panda, S. K. (2020) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes49360.2020.9379382 · Cited by 18
“For a cascaded modular SST (CMSST), the non-identical transformers and series inductors in stage2 (isolation stage) leads to unequal power transfer through each H-bridge, leading to unequal voltage stresses in the semiconductor devices and increased grid-current’s THD [6].”
BackgroundInfluentialYousefpoor, N., Parkhideh, B., Azidehak, A., Bhattacharya, S., & Fardanesh, B. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2302014 · Cited by 18
Self-citationPerformance analysis of electronic power transformer based on neuro-fuzzy controller
Açıkgöz, H., Keçecioğlu, Ö. F., Yıldız, C., Ganı, A., & Şekkeli, M. (2016) · SpringerPlus · doi:10.1186/s40064-016-2972-0 · Cited by 19
“…are as follows: (32) where, U DAB1 and U DAB2 are input and output DC voltages of DAB converter, f DAB is switching frequency of DAB converter, L DAB is leakage inductance, d DAB is ratio of time delay between two bridges to one-half of switching period (Yang et al. 2015; Zhao et al. 2013).”
BackgroundMethodA Unified Switch Loss Model and Design Consideration for Multilevel Boost PFC With GaN Devices
Wu, J. (2021) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2021.00032 · Cited by 17
Wang, X., Yang, M., Sima, W., Yuan, T., Sun, P., & Lin, S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3358023 · Cited by 17
Design and implementation of AC-DC hybrid multi-port energy router for power distribution networks
Yuan, L., Wei, S., Ge, J., Zhao, Z., & Huang, R. (2015) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2015.7385104 · Cited by 17
A 10 kV DC transformer (DCX) based on current fed SRC and 15 kV SiC MOSFETs
Zhu, Q., Wang, L., Zhang, L., & Huang, A. Q. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341001 · Cited by 17
Self-citationRobust Mixed H 2 / H ∞ Controller Design for Energy Routers in Energy Internet
Hua, H., Qin, Y., Geng, J., Hao, C., & Cao, J. (2019) · Energies · doi:10.3390/en12030340 · Cited by 17
A PWM Strategy Based on State Transition for Cascaded H-Bridge Inverter Under Unbalanced DC Sources
Ye, Z., Wang, T., Mao, S., Chen, A., Yu, D., Deng, X., Fernando, T. L., Chen, M., & Li, S. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2893936 · Cited by 17
“For the power control of three-phase unbalanced output, traditional zero-sequence voltage injection methods (ZSVIM) have been proven effective in three-phase CHB converters [30].”
MethodTian, J., Hu, D., Zhou, C., Yang, Y., Wu, W., Mao, C., & Wang, D. (2019) · IEEE Access · doi:10.1109/access.2019.2905006 · Cited by 13
“However, the individual dc voltage balance capacity of this strategy is quite limited, since the maximum allowed adjusted active power in the cascaded H-bridges is relatively small [22].”
BackgroundKiran, R., & Kalpana, R. (2022) · Canadian Journal of Electrical and Computer Engineering · doi:10.1109/icjece.2021.3130723 · Cited by 17
Effect of Dead Band and Transient Actions on CTPS Modulation for DAB DC–DC Converter and Solutions
Luo, S., Wu, F., & Wang, G. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3043316 · Cited by 17
Self-citationDirect State-of-Charge Balancing Control for Modular Multilevel Converter Integrating Batteries
Barresi, M., Simone, D. D., & Piegari, L. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3510876 · Cited by 16
“This assumption is reasonable since to avoid over-charging/discharging of the BPs, sorting algorithms to balance the BPs SOCs inside each arm are adopted [32], [33].”
Kim, S.-H., Kim, R.-Y., & Kim, S. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2917869 · Cited by 17
“From (1), the total power can be controlled through the PI controller in the dq-axis coordinate system, using the relational expression of the input power from the grid and the output power to the dc link [9], [18], [19].”
BackgroundChan, Y. P., Wong, C. S., & Loo, K. H. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2971106 · Cited by 16
“Besides energy storage systems, DAB converter is also frequently employed in many emerging applications, such as vehicle-to-grid systems [5] and solid state transformers [6].”
MethodSaha, J., Gorla, N. B. Y., & Panda, S. K. (2022) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-himeji2022-ecce53331.2022.9807000 · Cited by 16
“For the two-stage CMSST, both voltage-balance and power-balance controllers have been proposed in the literature [19]-[22], but the former leads to increased ig’s THD due to unequal mai requirement as explained in [22], [28].”
BackgroundFault tolerant cell design for MMC-based multiport power converters
Zapico, A., López, M., Rodríguez, A., & Briz, F. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855114 · Cited by 17
Sequence Pulse Modulation for Voltage Balance in a Cascaded H-Bridge Rectifier
Xu, P., He, X., Han, P., Lin, X., Shu, Z., & Gao, S. (2017) · Journal of Power Electronics · doi:10.6113/jpe.2017.17.3.664 · Cited by 16
Voltage balancing of modular smart transformers based on dual active bridges
Pugliese, S., Andresen, M., Mastromauro, R. A., Buticchi, G., Stasi, S., & Liserre, M. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8095935 · Cited by 16
“To reduce the effect of the power variations on the voltage variations without increasing the DClink capacitance, the DC-links in the CHB converter need to be balanced with fast dynamics [8].”
BackgroundThe Current Shaping Modular Multilevel DC–DC Converter
Gray, P. A., & Lehn, P. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2976001 · Cited by 18
“Two SST topologies that are scalable to higher voltages are identified in [10] as the modular multilevel converter structure (MMC) [11]–[13] and the input-series output-parallel structure (ISOP) [4], [14], [15].”
BackgroundHarrye, Y., Abdalla, A. A., & Mahasneh, H. (2023) · Energies · doi:10.3390/en16227577 · Cited by 15
Mon‐Nzongo, D. L., Lin, M., Ipoum‐Ngome, P. G., & Jin, T. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3427678 · Cited by 15
Real-time digital twin implementation of power electronics-based hydrogen production system
Deshmukh, R. S., Rituraj, G., Bauer, P., & Vahedi, H. (2025) · Energy Reports · doi:10.1016/j.egyr.2025.04.017 · Cited by 16
Active Gate Control method for Voltage Balancing of Series-Connected SiC MOSFETs
Kim, J., Yoon, D., & Cho, Y. (2019) · IEEE International Future Energy Electronics Conference (IFEEC) · doi:10.1109/ifeec47410.2019.9015009 · Cited by 15
“Thus, in the area of high voltage converters, the multilevel cascaded systems, and the series-connected devices system are the solution for sharing the high voltage of the devices [2], [4]–[16].”
BackgroundZhang, C., Wang, R., Shen, Z., Sadilek, T., Anurag, A., & Barbosa, P. M. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131313 · Cited by 17
“On the other hand, the input-series output-parallel (ISOP) configuration of converter modules enables the employment of reliable and cost-effective LV semiconductors [10], [11].”
BackgroundMou, D., Wang, H., Yuan, L., Luo, Q., Li, Y., Liu, W., & Zhao, Z. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3292848 · Cited by 15
“These applications, involving electric vehicles, power grids, and clean energy devices, require interconnection through multiport power electronic transformers (PETs) to ensure efficient power management, voltage conversion, and electrical isolation [8], [9], [10].”
BackgroundChattopadhyay, R., Raheja, U., Gohil, G., Viju Nair, R., & Bhattacharya, S. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341274 · Cited by 17
Self-citationSingle-Phase Multicell AC–DC Converter With Optimized Controller and Passive Filter Parameters
Alam, K. S., Xiao, D., Zhang, D., & Rahman, M. F. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2829674 · Cited by 15
“[4]–[6].”
Control Strategy for Single-Phase Open-Circuit Operation of a Modular Solid-State Transformer
Ouyang, S., Liu, J., Chen, X., & Yang, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2885562 · Cited by 15
“1) The CHB stage achieves MVdc control; meanwhile, the dc–dc stage achieves LVdc control [28], [29].”
BackgroundLiu, H., Ma, L., Song, W., & Lin, P. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3160199 · Cited by 16
“Unlike the conventional VBC method [5], [9], [21], [22], the proposed VBC method takes the difference edck as the input of the PI controller instead of the difference of dc-side voltage.”
MethodHybridized SVPWM Algorithm for Multilevel CHB Inverter With DC-Link Voltage Control Capability
Lewicki, A., Odeh, C. I., & Morawiec, M. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3426073 · Cited by 14
“Theinner-phasedc-linkvoltagebalancingcanbedoneusing PIcontrollers[22],[23],[24].”
Choi, D.-H., Park, J.-H., & Lee, J.-S. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3434712 · Cited by 14
“…the structure consists of dc–dc converters with medium-frequency transformers (MFTRs), the system is smaller in size and offers galvanic isolation, modularity, fault isolation, and a high degree of freedom for various control schemes compared to the conventional LFT-based types [10], [11], [12].”
Distributed power balance strategy for DC/DC converters in solid state transformer
Yu, X., She, X., Huang, A. Q., & Liu, L. (2014) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2014.6803428 · Cited by 14
“Another power balance method was presented in [6], while every DAB’s power needed to be calculated.”
BackgroundMethodSelf-citationVázquez, A., Rodríguez, A., Rogina, M. R., & Lamar, D. G. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2711521 · Cited by 15
Yang, D., Yin, L., Xu, S., & Wu, N. (2018) · Energies · doi:10.3390/en11092435 · Cited by 14
Jakka, V. N. S. R., Acharya, S., Anurag, A., Prabowo, Y., Kumar, A., Parashar, S., & Bhattacharya, S. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8592886 · Cited by 15
“Henceforth, the DAB of MUSESST is controlled using phase-shifted pulse width modulation technique [18].”
MethodSelf-citationLi, J., Chen, J., Gong, C., & He, Q. S. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3244543 · Cited by 14
Zhu, T., Zhou, L., Liu, M., Zhang, J., & Shi, L. (2015) · Scientific Reports · doi:10.1038/srep15802 · Cited by 14
“We can derive the relationship between the peak light signal change Δ Ipeak and the peak external space electric field intensity Eextpeak (parallel to the direction of the metal rods) as equation (1) and (2) (see more details in Supplementary information):”
BackgroundCurrent balancing control for multi-port hybrid AC/DC microgrid
Xiao, Q., Jia, H., Liang, B., & He, J. (2017) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2017.8273788 · Cited by 15
Farooqi, M. Z., Singh, B., & Panigrahi, B. K. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3366207 · Cited by 13
Deepti, T., Deepa, K., Stonier, A. A., Peter, G., Anoop, A., & Ganji, V. (2025) · IET Circuits Devices & Systems · doi:10.1049/cds2/6336609 · Cited by 13
Rahman, M. A., Islam, M. R., Muttaqi, K. M., & Sutanto, D. (2021) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2021.3137720 · Cited by 13
Optimal Components Selection for a DAB Model of CHB Converter
Barresi, M., Simone, D. D., Barzaghi, R., Dezza, S. C., Meraldi, L., Rosati, D., & Piegari, L. (2023) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2023.3258343 · Cited by 13
“Indeed, configurations based on modular solid-state transformers, combining CHB and DAB converters, were proposed in the literature to interface ac and dc distribution systems [11], [12], [13], [14], [15] or to connect different dc systems [16].”
BackgroundDesign and Optimization with Litz Wire Version of PCB in Solid-State Transformer
Li, Z., Feng, J., Lou, X. N., Li, Y.-H. H. Q., & Lee, F. C. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509347 · Cited by 13
DC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer
Zheng, L., Han, X., Kandula, R. P., & Divan, D. M. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3178433 · Cited by 14
“The applications of SST include renewable energy [6], traction [7], and utility distribution [8]–[10], where”
BackgroundJakka, V. N. S. R., Shukla, A., & Kulkarni, S. V. (2013) · IEEE India Conference · doi:10.1109/indcon.2013.6725915 · Cited by 13
“In most of the previous works ( [4], [7], [11], and [12]) related to active front-end rectifiers, phase locked loops (PLLs) are used for calculating the phase angle using which the sine and cosine components are calculated; this requires the reference frame transformation of the vectors.”
MethodNovel isolated cascaded half-bridge converter for battery energy storage systems
Jauch, F., & Biela, J. (2014) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2014.6910833 · Cited by 14
“This approach is similar to the conventional CHB converter where the balancing control of the DC-side capacitors or batteries is based on varying the amplitudes of the PWM generated sinusoidal voltages of a H-bridge module [6,14–16].”
MethodOperation of a three phase solid state-Transformer under unbalanced load conditions
Venkat, J., Shukla, A., & Kulkarni, S. V. (2014) · 2014 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES) · doi:10.1109/pedes.2014.7042116 · Cited by 12
Solid-State Transformers: A Review—Part II: Modularity and Applications
Predescu, D.-M., & Rosu, S. G. (2025) · Technologies · doi:10.3390/technologies13020050 · Cited by 15
“In SST applications, this structure was used at the input and output stages, in star and delta configurations, connecting the isolated converter to the modules’ capacitor [21,32,34–40].”
Implementation of DC/DC converter with high frequency transformer (DHFT) in hybrid AC/DC microgrid
Xiao, J., Nguyen, X. B., Wang, P., Huang, J., & Zhou, Q. (2017) · Asian Conference on Energy, Power and Transportation Electrification (ACEPT) · doi:10.1109/acept.2017.8168553 · Cited by 12
“Various DHFT topologies have been investigated and prototypes developed accordingly [6-9].”
BackgroundDesign and implementation of a PI-PBC to manage bidirectional power flow in the DAB of an SST
López-Rodríguez, K., Gil-González, W., & Mejía, A. E. (2022) · Results in Engineering · doi:10.1016/j.rineng.2022.100437 · Cited by 13
Liu, S., Zhu, H., Wang, S., Ma, L., Song, Z., Zhang, X., & Shu, Z. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3317279 · Cited by 12
“In [26], [27], and [28], the capacitor voltages of each cell are directly regulated by the proportional-integral (PI) controller, respectively.”
BackgroundAnalysis of a New Single-Stage AC/AC Converter for Solid-State Transformer
Khan, W., Dar, J. A., Parihar, K. S., & Pathak, M. K. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3343312 · Cited by 12
Liu, Y., Liu, S., Wang, C., Jiang, J., Li, J., & Ye, S. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3025976 · Cited by 12
Power balance modulation strategy for hybrid cascaded H-bridge multi-level inverter
Gong, R., Xue, B., Liu, J., & Zhang, X. (2021) · Electrical Engineering · doi:10.1007/s00202-021-01337-y · Cited by 12
“The output power unbalance between the same cascaded units will not only affect the service life of switching transistors and DC power supplies in H-bridge, but also hinder the maintenance and mass production of inverters in the later stage [13, 14].”
BackgroundDing, J., Geng, L., Zhang, H., Zhang, A., & Huang, J. (2021) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc52312.2021.9601547 · Cited by 13
“1 Introduction The isolated Dual-Active-Bridge (DAB) DC-DC converter is widely applied in spacecraft[1], power electronic transformers[2], electronic vehicles[3] and so on for its attractive advantages such as galvanic isolation, high power density, bidirectional energy flow, high power factor and zero-voltage-switchi…”
BackgroundPredictive current mode control of single phase dual active bridge DC to DC converter
Dutta, S., & Bhattacharya, S. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6647451 · Cited by 12
“The motivation to derive faster p control came from the requirement single phase Solid State Transform [10].”
Self-citationWang, Q., & Liang, D. (2016) · International Conference on Ecological Vehicles and Renewable Energies (EVER) · doi:10.1109/ever.2016.7476340 · Cited by 14
Zuo, Z., Yao, C., Dissado, L. A., Chalashkanov, N. M., & Dodd, S. J. (2017) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2017.006895 · Cited by 13
“However the emergence of power electronic technologies [5-10] has posed several new problems because of their highly compact configurations [5, 11], dramatically larger thermal dissipation [5, 12-14], very rapid polarity changes (high dv/dt) and high repetition frequencies of applied field pulses [5-7] far in excess o…”
BackgroundResearch of the high supply voltage quality control for solid‐state transformer
Tu, C., Xiao, F., Zheng, L. X., & Shuai, Z. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2017.0926 · Cited by 12
Li, Y., Sun, Q., Wang, D., & Lin, S. (2019) · Energies · doi:10.3390/en12030517 · Cited by 12
Grid-connected Self-synchronizing Cascaded H-Bridge Inverters with Autonomous Power Sharing
Dutta, S., Lu, M., Majmunović, B., Mallik, R., Seo, G., Maksimović, D., & Johnson, B. (2021) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce47101.2021.9595186 · Cited by 12
“typically rely on either a single centralized controller [6]–[8] or distributed controllers with a common communication bus for sending supervisory control commands and grid information [3], [9]–[15].”
BackgroundHigh-Accuracy Generalized Average Model of Dual Active Bridge Converters
Deshmukh, R. S., Bauer, P., & Vahedi, H. (2024) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2024.3382808 · Cited by 11
“…its invention in the early 1990s [2], it has been used in a plethora of applications such as in DC grids [3], [4], [5], [6], [7], [8], [9], Solid State Transformers (SSTs) [10], [11], [12], automotive applications [13], [14], [15], energy storage systems [16], [17], [18], and aerospace [19], [20].”
BackgroundMartin-Arnedo, J., González-Molina, F., Martínez-Velasco, J. A., & Adabi, M. E. (2017) · Energies · doi:10.3390/en10040521 · Cited by 11
Li, Z., Feng, J., Hsieh, Y.-H., & Li, Q. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131159 · Cited by 12
“SST steps down the mediumvoltage AC (MVAC) directly to low-voltage DC with minimal power conversion stages [1]-[2].”
BackgroundA Control Strategy for Solid-State Transformers With Coupled Load Disturbance Attenuation Ability
Sarda, R., Rodríguez, E., Gorla, N. B. Y., Farivar, G. G., Pou, J., Li, Y. H., Vaisambhayana, S., & Tripathi, A. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3346687 · Cited by 12
“Finally, a two-level inverter interfaces the LV dc-link and the LV ac-side voltage, forming Stage III [1], [5], [10], [11].”
BackgroundMethodInfluentialVoltage and current balance control for the ISOP converter-based power electronic transformer
Xu, K., Fu, C., Wang, Y., & Wang, H. (2015) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2015.7385062 · Cited by 12
Control strategy of a multi-level converter with multi-winding MFT/HFT isolation
Gu, C., Zheng, Z., & Li, Y. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953906 · Cited by 11
“To improve the reliability and flexibility, and decrease the size/volume of the system at the same time, a variety of medium frequency transformer (MFT) or high frequency transformer isolated topology is proposed [2-8].”
BackgroundMa, X., Yang, X., Zhang, F., Huang, L., Li, Z., & Song, H. (2017) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2017.7930736 · Cited by 12
“The DAB power unbalance is solved in [5] and [6].”
BackgroundMethodRodrigues, W. A., de Oliveira, T. R., Morais, L. M. F., & Rosa, A. H. R. (2018) · Energies · doi:10.3390/en11071802 · Cited by 13
Four-Port, Single-Stage, Multidirectional AC–AC Converter for Solid-State Transformer Applications
dos Santos, C. A., Mazza, L. C. D. S., Tofoli, F. L., Oliveira, D. S., Praça, P. P., & Antunes, F. L. M. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3082059 · Cited by 13
“This limitation can be overcome by the cascade H-bridge configuration in terms of a modular approach, but proper control schemes should be adopted to avoid the dc-link voltage and power unbalance in the cascaded modules [7].”
BackgroundSensor-Reduction Control for Dual Active Bridge Converter Under Dual-Phase-Shift Modulation
Duong, T.-Q., & Choi, S.-J. (2022) · IEEE Access · doi:10.1109/access.2022.3182510 · Cited by 11
A fault tolerant control approach for a three-stage cascaded multilevel solid state transformer
Gorla, N. B. Y., Kolluri, S., Chauhan, P. J., & Panda, S. K. (2017) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2017.8013310 · Cited by 11
A triple port active bridge converter based multi-fed power electronic transformer
Jakka, V. N. S. R., & Shukla, A. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854797 · Cited by 11
“Multilevel converters and modern semiconductor devices can be employed in PET technology to achieve medium voltage operation [7]-[9].”
BackgroundFlexible Power Electronic Converters for Producing AC Superimposed DC (ACsDC) Voltages
Jakka, V. N. S. R., Shukla, A., & Kulkarni, S. V. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2750624 · Cited by 10
“used to control the input stage converters [30].”
MethodPartial Fluctuation Power Control of Resonant Converter in Solid-State Transformer
Li, Z., Zhao, C., Hsieh, Y. L., Li, Q., & Lee, F. C. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3347828 · Cited by 10
“Increasing the bus voltage ripple may be a solution [9].”
BackgroundMethodInfluentialPowerline communications strategy enabling fully decentralized control of AC-stacked PV inverters
Evans, D., & Cox, R. W. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096443 · Cited by 10
“These benefits have resulted in many research and development efforts to control and finally adopt the general cascaded H-bridge topology for PV applications [11-15].”
BackgroundA DC Short-Circuit Fault Ride Through Strategy of MMC-HVDC Based on the Cascaded Star Converter
Wang, Y., Yang, B., Zuo, H., Liu, H., & Yan, H. (2018) · Energies · doi:10.3390/en11082079 · Cited by 11
“The method is same as that of conventional three-phase cascaded star converter [31].”
MethodA Scalable Soft-Switching Photovoltaic Inverter With Full-Range ZVS and Galvanic Isolation
Moosavi, M., Naghavi, F., & Toliyat, H. A. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2984756 · Cited by 10
“In CHB+DAB topologies, extra control measures need to be taken to manage the voltage and power unbalance in the cascaded modules as it increases the stress on devices and leads to overcurrent and overvoltage problems [38], [39].”
BackgroundChen, S., Yu, W., & Wang, D. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3088390 · Cited by 10
SST-Based Grid Reinforcement for Electromobility Integration in Distribution Grids
Joglekar, C., Mortimer, B. J., Ponci, F., Monti, A., & Doncker, R. W. D. (2022) · Energies · doi:10.3390/en15093202 · Cited by 10
Trapezoid current modulated DCM AC/DC DAB converter for two-stage solid state transformer
Zengin, S., & Boztepe, M. (2015) · National Conference on Electrical and Electronics Engineering (ELECO) · doi:10.1109/eleco.2015.7394538 · Cited by 12
“On the other hand, since the phase shifted DAB converter operates under the Continuous Conduction Mode (CCM), expensive high frequency current sensors must be used [21].”
BackgroundControl Strategy of Single-Phase Three Level Neutral Point Clamped Cascaded Rectifier
He, X., Lin, X., Xu, P., Han, P., Shu, Z., & Gao, S. (2017) · Energies · doi:10.3390/en10050592 · Cited by 10
“In this paper, an overall control strategy combined with a PI-based multi-module balancing scheme is proposed to control one grid current plus n dc terminal voltages [25].”
MethodWang, S., Zhu, L., Wang, Y., Yang, J., Zhou, Y., & Shu, Z. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3381821 · Cited by 9
“Voltage-balancing control strategies adjust the active power input of each cell to modify the corresponding modulation signal of the individual cell, thereby achieving a balanced distribution of energy [9], [10], [11], [12], [13].”
BackgroundA Three-Phase Unfolding-Based Solid-State Traction Transformer for Railway Application
Khan, A., Nag, S. S., & Singh, B. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3529467 · Cited by 10
“An SST utilizing a dual active bridge (DAB) as the dc–dc stage is presented in [11] for the distribution system.”
Evaluation of Double-Line-Frequency Power Flow in Solid-State Transformers
Li, Z., Hsieh, Y.-H., Li, Q., Lee, F. C., & Zhao, C. (2021) · IEEE International Conference on DC Microgrids · doi:10.1109/icdcm50975.2021.9504649 · Cited by 10
A Transformer Design with PCB Litz Wire Concept for Solid State Transformer
Li, Z., Feng, J., Lou, X., Hsieh, Y.-H., Li, Q., & Lee, F. C. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362376 · Cited by 9
Deepti, T., Deepa, K., Stonier, A. A., Peter, G., Anoop, A., Shahila, D. F. D., Ganji, V., & Jha, A. (2025) · IET Circuits Devices & Systems · doi:10.1049/cds2/3536991 · Cited by 10
Independent DC link voltage control of cascaded multilevel PV inverter
Huang, Q., Yu, W., & Huang, A. Q. (2016) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2016.7468249 · Cited by 9
Self-citationObserver-based decoupling power control for frequency modulated Dual-Active-Bridge converter
Nguyen, D., & Fujita, G. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512380 · Cited by 9
Metadata
- Authors
- Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q.
- Affiliations
- Eaton (United States) (US)
- North Carolina State University (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-04
- Volume
- 28
- Issue
- 4
- Pages
- 1523-1532
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1999302015
- Cited by
- 642
- References
- 22
- Citations by year
- 2026: 23 · 2025: 41 · 2024: 51 · 2023: 47 · 2022: 63 · 2021: 40 · 2020: 59 · 2019: 70 · 2018: 56 · 2017: 63 · 2016: 44 · 2015: 29 · 2014: 37 · 2013: 19
- FWCI
- 17.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- solid-state transformer, cascaded H-bridge converter, dual active bridge converter, DC-link voltage balancing, power balancing, AC-DC rectifier, DC distribution systems, d-q model, power constraints, parallel converter modules
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.