Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The solid-state transformer (SST) is an interface device between ac distribution grids and dc distribution systems. The SST consists of a cascaded multilevel ac/dc rectifier stage, a dual active bridge (DAB) converter stage with high-frequency transformers to provide a regulated 400-V dc distribution, and an optional dc/ac stage that can be connected to the 400-V dc bus to provide residential 120/240 V$_{\rm ac}$. However, due to dc-link voltage and power unbalance in the cascaded modules, the unbalanced dc-link voltages and power increase the stress of the semiconductor devices and cause overvoltage or overcurrent issues. This paper proposes a new voltage and power balance control for the cascaded H-Bridge converter-based SST. Based on the single-phase dq model, a novel voltage and the power control strategy is proposed to balance the rectifier capacitor voltages and the real power through parallel DAB modules. Furthermore, the intrinsic power constraints of the cascaded H-Bridge voltage balance control are derived and analyzed. With the proposed control methods, the dc-link voltage and the real power through each module can be balanced. The SST switching model simulation and the prototype experiments are presented to verify the performance of the proposed voltage and power balance controller.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530601 · Cited by 2,665 · cited 1×
“The SST has the features of instantaneous voltage regulation, voltage sag compensation, fault isolation, power factor correction, harmonic isolation, and dc output [1]–[4].”
BackgroundMultilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.502161 · Cited by 2,604
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401 · cited 1×
“The low-voltage dc link is regulated by the DAB converter [16], [19].”
BackgroundResearch on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 1×
“One of the main disadvantages of the cascaded H-bridge rectifier is the voltage unbalance of the dc-link voltages at different H-Bridges [5]–[7], [12], [13], [18], [20].”
BackgroundSelf-citationIndividual Voltage Balancing Strategy for PWM Cascaded H-Bridge Converter-Based STATCOM
Barrena, J. A., Marroyo, L., Rodriguez Vidal, M. Á., & Torrealday Apraiz, J. R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906127 · Cited by 335 · cited 1×
“[8] present an individual voltage-balancing strategy to balance the dc-link voltage with PWM.”
BackgroundA power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
A grid simulator with control of single-phase power converters in D-Q rotating frame
Zhang, R., Cardinal, M., Szczesny, P., & Dame, M. (2003) · 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289) · doi:10.1109/psec.2002.1022377 · Cited by 281 · cited 1×
“The single-phase dq transformation is applied to the (5) and (6) [14], and the differential equations in dq coordinates are Fig.”
MethodA Power Electronic-Based Distribution Transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4312081 · Cited by 264
A Modular Strategy for Control and Voltage Balancing of Cascaded H-Bridge Rectifiers
Iman-Eini, H., Schanen, J.-L., Farhangi, S., & Roudet, J. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002055 · Cited by 205 · cited 1×
“[9] present a method that ensures the dc-link voltages converge to the reference value when load power are different.”
MethodMultilevel intelligent universal transformer for medium voltage applications
Lai, J.-S., Maitra, A., Mansoor, A., & Goodman, F. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518705 · Cited by 185
Cited by
Items 101–200 of 651
Energization and Start-Up of CHB-Based Modular Three-Stage Solid-State Transformers
Saeed, M., Cuartas, J. M., Rodríguez, A., Arias, M., & Briz, F. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2844806 · Cited by 43
Quad-Active-Bridge Converter With Current Balancing Coupled Inductor for SST Application
Naseem, N., & Cha, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3076460 · Cited by 44
“It provides strong magnetic coupling between the windings to effectively balance the currents, addressing a serious problem in the SST industry.”
MethodInfluentialTian, Y., Chen, Z., Deng, F., Sun, X., & Hu, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2375573 · Cited by 42
“[19] introduced an unbalance power control method for multiterminal solid state transformer, and it used the topology of paralleled DABs connected to one inverter.”
MethodWang, L., He, J., Han, T., & Zhao, T. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2991646 · Cited by 45
“With advanced power electronics technologies adopted in these DER systems [3]–[5], such as grid-tied inverters [6], [7], and solid-state transformers [8], the power converter is playing a significant role to transmit and synchronize the generated power from the front-end machine to the utility grid.”
BackgroundSelf-citationFast DC-Bias Current Control of Dual Active Bridge Converters With Feedforward Compensation
Ji, Z., Wang, Q., Li, D., & Sun, Y. (2019) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2019.2957790 · Cited by 41
“AS A typical topology of an isolated bidirectional DC-DC converter, dual-active-bridge (DAB) [1], [2] converters are widely used across different applications due to their high efficiency, high power density, and low cost [3]–[5].”
BackgroundBasu, K., & Mohan, N. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2311393 · Cited by 43
“A three stage PET usually involves a high frequency link DC/DC converter [10] [11] [12]”
BackgroundMa, J., Song, W., Jiao, S., Zhao, J., & Feng, X. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2516959 · Cited by 43
Mollik, M. S., Hannan, M. A., Reza, M. S., Rahman, M. S. A., Lipu, M. S. H., Ker, P. J., Mansor, M., & Muttaqi, K. M. (2022) · Electronics · doi:10.3390/electronics11172648 · Cited by 41
“The 400 V DC port on the SST makes it easier to connect certain types of DRERs and DESDs [8].”
BackgroundXue, H., & He, J. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3229317 · Cited by 38
“When the modulation indices (MIs) of all H-bridge modules are less than 1, the traditional sinusoidal pulsewidth modulation (SPWM) is well applied [8], [9], [10], [11], [12].”
BackgroundMethodReduced-Order Observer-Based Control System for Dual-Active-Bridge DC/DC Converter
Nguyen, D., Fujita, G., Bui-Dang, Q., & Ta, M. C. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2810805 · Cited by 41
“Among those, the DAB converter has shown to be the key component as it enables isolation, bidirectional power transmission, size reduction (due to operating at high frequency) and asynchronous interconnection capabilities of the SST [2], [3].”
BackgroundMou, D., Yuan, L., Li, J., Hou, N., Li, J., Li, Y., & Zhao, Z. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3182331 · Cited by 38
“the dual active bridge (DAB) converter has gradually become one of the most promising topologies and is widely used in solid-state transformers [2], [3], data centers [4], and energy storage [5] due to its powerful bidirectional power transfer capability, inherent soft-switching characteristics, and easy modularity [6…”
BackgroundNew Bidirectional Intelligent Semiconductor Transformer for Smart Grid Application
Han, B.-M., Choi, N.-S., & Lee, J.-Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2284009 · Cited by 37
Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies
Wang, X., Liu, J., Ouyang, S., & Meng, F. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2331701 · Cited by 37
“it attracted increasing interest from both academia and industry, and significant progress was made in the last two decades [5]–[18].”
BackgroundInfluentialFlexible distribution network: definition, configuration, operation, and pilot project
Xiao, J., Ying, W., Luo, F., Bai, L., Gang, F., Huang, R., Jiang, X., & Zhang, X. (2018) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2018.5641 · Cited by 38
Hu, Y., Li, Z., Zhang, H., Zhao, C., Gao, F., Luo, L., Luan, K., Wang, P., & Li, Y. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2965232 · Cited by 38
“One challenge for SST is to achieve medium-voltage (MV) ac voltage such as 10 kV, among which Cascaded H-bridges (CHBs) are widely used to address this issue [11]–[16].”
BackgroundRodriguez, L. A. G., Jones, V., Oliva, A., Mejía, A. E., & Balda, J. C. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2677523 · Cited by 37
Bipu, M. R. H., Montes, O. A., Teng, F., Wang, D., Awal, M. A., Yu, W., Husain, I., & Lukic, S. M. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3462920 · Cited by 35
“In Type A, the most prevailing architecture, the CHBs control the MV DC link voltages while the DABs control the LV DC bus voltage [13]–[15].”
Yang, S., Zhang, X., Mao, W., Hu, Y., Wang, M., Wang, F., & Cao, R. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3024282 · Cited by 35
“In detail, according to the way of reactive power distribution, they can be divided into three categories, which are: the system reactive power is distributed by each H-bridge unit in proportion to their dc-side input power [16]–[20], the system reactive power is undertaken by the specific H-bridge unit [21]–[23], and…”
BackgroundIraklis, A., Schirmer, T., Dittus, H., Lusiewicz, A., & Winter, J. (2019) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2019.2895500 · Cited by 35
“A bidirectional DAB configuration was used on 5 kVDC input and 700 VDC output DC-links.”
BackgroundInfluentialSaha, J., & Panda, S. K. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.113118 · Cited by 36
A SYSTEMATIC LITERATURE REVIEW ON ENERGY-EFFICIENT TRANSFORMER DESIGN FOR SMART GRIDS
Manager Grade-1, P. &. M., Khan, M. A. M., Haque, R., Apex Footwear limited, D., Bajwa, A., & Instrumentation and Control Engineer, A. M. A. A. G. (2022) · American Journal of Scholarly Research and Innovation · doi:10.63125/6n1yka80 · Cited by 35
Zheng, L., Han, X., Kandula, R. P., Kandasamy, K., Saeedifard, M., & Divan, D. (2020) · 2020 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec39645.2020.9124244 · Cited by 33
“sources/loads integration, reactive power compensation, harmonics filtering, and voltage regulation etc can be provided at the same time [1]-[2].”
BackgroundControl Design of Series-Connected PV-Powered Grid-Forming Converters via Singular Perturbation
Mallik, R., Majmunović, B., Dutta, S., Seo, G., Maksimović, D., & Johnson, B. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3221331 · Cited by 34
“Focusing on cascaded topologies, such as modular multilevel converters [1] and cascaded H-bridges [2], [3], centralized controllers have been traditionally used to regulate voltages, power, and frequency across the system.”
MethodOperation and control of MMCs using cells with power transfer capability
Briz, F., López, M., Zapico, A., Rodríguez, A., & Reigosa, D. (2015) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2015.7104468 · Cited by 35
“4c) [17].”
Zhu, Q., Wang, L., Chen, D., Zhang, L., & Huang, A. Q. (2017) · 2017 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8095938 · Cited by 32
“Different power conversion topologies and applications of SST family have been implemented and presented [1-12].”
BackgroundMethodSelf-citationComprehensive Power Losses Model for Electronic Power Transformer
Yue, Q., Li, C., Cao, Y., He, Y., Cai, B., Wu, Q., & Zhou, B. (2018) · IEEE Access · doi:10.1109/access.2018.2791587 · Cited by 34
“First, the EPT can correct the power factor at the input side to independently adjust the power factor of the distribution network [22], which ensures the distribution network remains at unity power factor operation.”
BackgroundWang, Z., Li, C., Liu, J., & Zheng, Z. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3228338 · Cited by 32
“as energy storage systems [2], [3], automotive applications [4], [5], solid-state transformers [6], [7], microgrids [8], [9], [10], etc.”
BackgroundKasper, M., Chen, C.-W., Bortis, D., Kolar, J. W., & Deboy, G. (2015) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2015.7104333 · Cited by 31
“In [14] a voltage balance control is presented which is based on the single-phase dq-control for the rectifier, and a power balance control method to regulate the power transferred through the DC-DC converter that are connected in parallel at their outputs.”
BackgroundMethodAn Efficient Modulation Strategy for Cascaded Photovoltaic Systems Suffering From Module Mismatch
Wang, C., Zhang, K., Xiong, J., Xue, Y. S., & Liu, W. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2756338 · Cited by 34
“Module mismatch problems for some other cascaded converter applications, such as static synchronous compensators (STATCOM), and solid-state transformers, have been studied in previous work [6]–[8].”
BackgroundQu, Z.-W., Yao, Y., Wang, Y.-J., Zhang, C.-J., Chong, Z., & Abu-siada, A. (2019) · IEEE Access · doi:10.1109/access.2019.2933414 · Cited by 23
Partial Fluctuating Power Control of Resonant Converter for Solid-State Transformer
Li, Z., Zhao, C., Hsieh, Y.-H., & Li, Q. (2022) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43599.2022.9773455 · Cited by 31
“The SST steps down the mediumvoltage AC directly to low-voltage DC with minimal power conversion stages [1]-[2].”
BackgroundInfluentialAn, F., Song, W., Yang, K., Luo, S., & Feng, X. (2019) · IET Power Electronics · doi:10.1049/iet-pel.2018.5056 · Cited by 31
Zheng, L., Kandula, R., & Divan, D. (2021) · IEEE transactions on power electronics · doi:10.1109/tpel.2021.3085679 · Cited by 20
“, 40 ms to hundreds of milliseconds in [17]–[20], which verifies the great performance of the proposed predictive control on the reduced dc-link SST.”
BackgroundSelf-Synchronizing Cascaded Inverters With Virtual Oscillator Control
Lu, M., Dutta, S., & Johnson, B. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3134662 · Cited by 30
Zhao, X., Liu, Y., Chai, X., Guo, X., Wang, X., Zhang, C., Wei, T., Shi, C., & Jia, D. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3170936 · Cited by 30
“In [13], a voltage and power balance control strategy based on the single-phase dq vector control is”
MethodA Modular Multilevel Converter with Power Mismatch Control for Grid-Connected Photovoltaic Systems
Duman, T., Marti, S., Moonem, M. A., Kader, A. A., & Krishnaswami, H. (2017) · Energies · doi:10.3390/en10050698 · Cited by 30
“Various control strategies have been described in literature in order to regulate such unbalance for cascaded inverters in solid state transformer (SST) applications [22,25].”
BackgroundIsobe, T., Barrera-Cárdenas, R., He, Z., Zou, Y., Terazono, K., & Tadano, H. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2923785 · Cited by 31
Moeini, A., & Wang, S. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2770141 · Cited by 29
“The CHB multilevel topology with isolated dc loads is used in many applications such as hybrid CHB multilevel inverter motor drive [3], CHB converter based solid-state transformer [4], CHB STATCOM [5], and CHB electrical vehicle charging station [6].”
MethodWang, M., Wei, S., Mou, D., & Wu, P. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3169059 · Cited by 29
A Novel Bidirectional DC/AC Stacked Matrix Converter Design for Electrified Vehicle Applications
Sangdehi, S. M. M., Hamidifar, S., & Kar, N. C. (2014) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2014.2325740 · Cited by 29
A Rotational Control in Medium-Voltage Modular Solid-State Transformer-Based Converter System
Dong, D., Raju, R., Ganireddy, G., & Agamy, M. S. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2932958 · Cited by 31
“[25]–[28] presented the control loop design to balance power among SST converter units as well as ac-side control response improvement.”
BackgroundA novel low voltage ride through strategy for cascaded power electronic transformer
Han, J., Kong, X., Li, P., Zhang, Z., & Yin, X. (2019) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-019-0137-1 · Cited by 30
Analysis and Optimization of Voltage Balancing Control Limits for Cascaded H-Bridge Rectifiers
Wang, S., Jiao, N., Ma, J., Liu, T., & Liu, X. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3032874 · Cited by 28
Zheng, L., Kandula, R. P., Kandasamy, K., & Divan, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3050115 · Cited by 28
“In [15], the CHBs control average dc-link voltage and voltage balancing, while the IBDCs regulate the LV-side voltage.”
BackgroundDao, N. D., Nguyen, H. V., & Lee, D. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3152501 · Cited by 29
Development and testing of a bidirectional distribution electronic power transformer model
Alepuz, S., González-Molina, F., Martin-Arnedo, J., & Martínez-Velasco, J. A. (2013) · Electric Power Systems Research · doi:10.1016/j.epsr.2013.10.010 · Cited by 30
A Novel DC-Power Control Method for Cascaded H-Bridge Multilevel Inverter
Ye, Z., Jiang, L., Zhang, Z., Yu, D., Wang, Z., Deng, X., & Fernando, T. L. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2686798 · Cited by 28
Zhu, X., Jiang, L., Zhang, B., & Jin, K. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3157618 · Cited by 27
“Compared with the former two kinds of converters, cascaded H-bridge converter is more suitable for medium- and high-voltage applications and has the advantages of small voltage stress on cells, flexible control strategy, and easy level expansion [14], [15].”
BackgroundSong, W., Zhong, M., Deng, Y., Yin, S., & Yu, B. (2022) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2022.3174800 · Cited by 28
“W ITH salient features such as high power density and high efficiency, the power electronic transformer (PET) has attracted more and more attentions in applications such as dc microgrid [1], renewable energy system [2], and railway traction system [3], [4].”
BackgroundOperation and Performance of Resonant Modular Multilevel Converter With Flexible Step Ratio
Zhang, X., Xiang, X. J., Green, T. C., & Yang, X. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2677333 · Cited by 27
“of solid-state transformers and power electronics transformers, with the former being used in distribution networks [17] and the latter being used in traction systems [18], [19].”
BackgroundYeh, C.-S., Zhang, L., Choe, J., Chen, C., Yu, O., & Lai, J. (2018) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2018.8341313 · Cited by 31
Medium-Voltage Solid-State Transformer Design for Large-Scale H 2 Electrolyzers
Li, Z., Mirzadarani, R., Niasar, M. G., Itraj, M., Lieshout, L. V., Bauer, P., & Qin, Z. (2024) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2024.3414151 · Cited by 26
“Different topologies are feasible for SST, and one frequently mentioned topology in the literature is the cascaded structure [9], [10].”
BackgroundSolid state transformer with low-voltage ride-through and current unbalance management capabilities
Alepuz, S., Gonzalez, F., Martin-Arnedo, J., & Martínez, J. A. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699316 · Cited by 27
“The list of these capabilities includes power factor correction, bidirectional active power flow control, reactive power control at both SST sides, instantaneous voltage regulation,voltage sag compensation (low-voltage ride-through –LVRT–), harmonic compensation, auto-balancing and variable-frequency output [6], [7],…”
BackgroundRipple Voltage Suppression and Control Strategy for CHB-Based Solid-State Transformer
Xiao, F., Tu, C., Ge, Q., Zhou, K. S., Guo, Q., & Zheng, L. X. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2959786 · Cited by 26
“For cascade H-bridge (CHB)-based SST, the double frequency component of ac power on the dc-link is unavoidable [11].”
BackgroundFeng, M., Gao, C., Ding, J., Ding, H., Xu, J., & Zhao, C. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3061421 · Cited by 26
“1 includes three phase legs (PLs) each with dozens of cascaded connected CHB-DABs, which is also known as power module (PM) [8].”
BackgroundLi, X., Cheng, L., He, L., Wang, C., & Zhu, Z. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3138594 · Cited by 26
A Data-Driven Control Parameters Optimization Method for Dual Active Bridge Converters
Xiao, Z., Jiang, Y. Y., Deng, F., Yao, Z., & Tang, Y. K. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3370950 · Cited by 26
“Due to these benefits, the DAB topology finds widespreadapplicationinvariousfields,includingdcmicrogrids [1],[2],automotivesystems[3],[4],distributionsystems[5],and asanisolationstageinsolid-statetransformers[6],[7],[8].”
BackgroundKim, S.-H., Jang, Y.-H., & Kim, R.-Y. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2871789 · Cited by 27
Zhang, X., Xu, Y., Siddique, A., Long, Y., & Xiao, X. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2946463 · Cited by 26
Zheng, T., Gao, C., Liu, X., Liao, X., Li, Z., Sun, B., & Lv, J. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2962486 · Cited by 26
Xue, H., & He, J. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3406862 · Cited by 25
Shu, Z., Kuang, Z., Wang, S., Xu, P., & He, X. (2015) · IEEE International Future Energy Electronics Conference (IFEEC) · doi:10.1109/ifeec.2015.7361418 · Cited by 25
Yang, D., Wu, N., Yin, L., & Lu, Z. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2760852 · Cited by 26
“It has been employed in solid-state transformers [3], [4], static synchronous compensators [5], [6], grid-connected photovoltaic (PV) systems [7]–[9], and active rectifier [10].”
Deadbeat control for a single‐phase cascaded H‐bridge rectifier with voltage balancing modulation
Qi, C., Chen, X., Tu, P., & Wang, P. (2017) · IET Power Electronics · doi:10.1049/iet-pel.2016.0933 · Cited by 25
“This feature makes CHB rectifier an appealing topology to be used, for example, in traction applications [3] and solid-state transformers (SSTs) [5, 6, 8].”
BackgroundLin, H., Chung, H. S.-H., Lin, C., Xie, D., Deng, Q., Lyu, M., Goetz, S. M., Chen, J., & Ge, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3618228 · Cited by 24
Zhang, M., Du, Z., Lin, X., & Chen, J. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2402835 · Cited by 24
“devices (DESDs), and loads are integrated at the low-voltage side of solid state transformer (SST) [3], [4].”
BackgroundDong, L., Zhang, T., Pu, T., Chen, N., & Sun, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2949378 · Cited by 24
“And the low voltage AC/DC ports of PET are obtained from the low voltage DC bus of DC/DC isolation transformer in general [4], [44], [45].”
BackgroundLi, Y., Sun, Q., Qin, D., Cheng, K., & Li, Z. (2020) · IEEE Access · doi:10.1109/access.2020.2987075 · Cited by 23
“Based on [16], a novel voltage balance control strategy was proposed to settle the voltage imbalance that could arise to the dc links of different HVDC bus [17].”
BackgroundA Bidirectional Matrix-Based AC-DC Dual-Active Bridge for Modular Solid-State-Transformers
Saha, J., Gorla, N. B. Y., & Panda, S. K. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9255301 · Cited by 24
“The Cascaded H-Bridge (CHB) based Cascaded Modular SST (CMSST), proposed and implemented in the Future Renewable Electrical Energy Delivery and Management (FREEDM) Systems Center, is the conventional topology that involves a two staged MVAC-LVDC conversion [6].”
MethodDesign and Control of a High-Power Wide-Gain-Range LLC Resonant Converter
Zhao, C., Feng, J., Li, Z., Hsieh, Y.-H., Lee, F. C., & Li, Q. (2022) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43599.2022.9773412 · Cited by 23
“Only a few high-power LLC converters operate as D2D converters, achieving given gain regulation requirements [10]-[15].”
BackgroundSaha, J., Gorla, N. B. Y., & Panda, S. K. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3362830 · Cited by 23
Voltage and power balance control strategy for three-phase modular cascaded solid stated transformer
Zhang, Z., Zhao, H., Fu, S., Shi, J., & He, X. (2016) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2016.7468063 · Cited by 23
“Detailed modeling analysis can be illustrated in [17]-[19].”
BackgroundMethodInfluentialZhu, Q., Wang, L., Zhang, L., Yu, W., & Huang, A. Q. (2016) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2016.7468196 · Cited by 27
“nary smart g onic technolo copper and ir h needed sm gement and fa former, the SS hile having t lation, harmon [1-3].”
BackgroundSelf-citationComparative analysis of modular multiport power electronic transformer topologies
López, M., Briz, F., Saeed, M., Arias, M., & Rodríguez, A. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854932 · Cited by 24
“Practical implementation of this concept can be found in [5], [10], [11].”
BackgroundDesign of a robust PI controller for a dual active bridge converter
Koch, G. G., Queiroz, S. S., Rech, C., Oliveira, R. C. L. F., Borges, R. A., Tognetti, E. S., & MONTAGNER, V. F. (2016) · IEEE International Conference on Industry Applications · doi:10.1109/induscon.2016.7874503 · Cited by 25
“In [5], it is studied a single-phase battery charger for power applications, based on DAB topology.”
MethodJafarian, H., Kim, N., Parkhideh, B., & Enslin, J. H. R. (2017) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2017.7931214 · Cited by 22
“Therefore, despite the distributed nature of this architectures, in all the proposed control schemes, output active and reactive power are controlled centrally [18-25].”
BackgroundUnified Description and Optimization Method of Dual Active Bridge DC–DC Converters
Xiao, Z., He, Z., Li, Z., Zhu, L., & Wang, L. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3177245 · Cited by 22
“DAB are widely adopted in dc microgrid [1]–[4], automotive application [5], [6], distribution system [7], and the isolation stage in solid-state transformers (SSTs) [8]–[12].”
BackgroundRehman, A., Imran-Daud, M., Haider, S. K., Rehman, A. U., Shafiq, M., & Eldin, S. M. (2022) · Symmetry · doi:10.3390/sym14102027 · Cited by 24
Medium Voltage Solid State Transformer for Extreme Fast Charging Applications
Awal, M. A., Montes, O. A., Teng, F., Wang, D., Bipu, M. R. H., Yu, W., Lukic, S. M., & Husain, I. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131285 · Cited by 24
Cao, H., Du, L., Guo, F., Ma, Z., & Zhao, Y. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362803 · Cited by 22
“In the existing literature, a zero-sequence voltage is injected into the output voltage of CHB, together with more solutions reported in [1] and [5].”
BackgroundChan, Y. P., Yaqoob, M., Wong, C. S., & Loo, K. H. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2926070 · Cited by 22
Topology and Control Method of a Single-Cell Matrix-Type Solid-State Transformer
Wang, H., Zhang, Y., Sun, Y., Zheng, M., Liang, X. P., Zhang, G., Tan, K., & Feng, J. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2940514 · Cited by 22
“However, this configuration has the disadvantages of complex structures and control methods [25]-[27], which cause the power density reduction and reliability issue.”
BackgroundControl of a three-stage three-phase cascaded modular power electronic transformer
Wang, X., Liu, J., Xu, T., Wang, X., & Xiong, L. (2013) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2013.6520468 · Cited by 21
“Literatures [15, 16] supposed different control strategies for the FREEDM single-phase SST which has common low-voltage DC link.”
MethodModel Predictive Control of Dual Active Bridge Converter Based on the Lookup Table Method
Gao, G., Lei, W., Cui, Y., Li, K., Hu, X., Xu, J., & Lv, G. (2019) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2019.8807650 · Cited by 21
Power Electronics Converters for the Internet of Energy: A Review
Granata, S., Benedetto, M. D., Terlizzi, C., Leuzzi, R., Bifaretti, S., & Zanchetta, P. (2022) · Energies · doi:10.3390/en15072604 · Cited by 22
A Hybrid Data-Driven Power Loss Minimization Method of Dual-Active Bridge Converters
Xiao, Z., Jiang, Y. Y., Yao, Z., He, Z., Jiang, Y., Li, Y., & Tang, Y. K. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3368330 · Cited by 21
“These features have made DAB a popular choice for various applications, such as energy storage systems [3], [4], [5], microgrids [6], [7], [8], automation applications [9], [10], [11], and solid-state transformers [12], [13], [14].”
BackgroundZhang, B., Yang, X., Qiao, L., Huang, L., Ma, X., Xu, P. F., & Hao, X. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512437 · Cited by 21
“The typical SST consists of multi-stages sub-modules, in a structure of LV-side paralleled and HV-side cascaded, with the following advantages and characteristics, such as low voltage and current stress of switches, soft switching operation, high power density, bi-directional power flow and good line-side performance[…”
BackgroundDian, R., Xu, W. M., & Mu, C. (2016) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2016.2602401 · Cited by 21
“6, The load current is rich in harmonics, in which the amplitude of the fifth harmonic is about 3.6 A. Fortunately, the harmonics of the grid current during the APF operation has decreased greatly, whose fifth harmonic has dropped to below 0.5 A, and the waveform is nearly sinusoidal.”
BackgroundInfluentialNasr, M., Poshtkouhi, S., Radimov, N., Cojocaru, C., & Trescases, O. (2017) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2017.7930837 · Cited by 22
“1 [10], has slow dynamic performance and requires a costly high-speed oversampling ADC for the current loop.”
BackgroundSimultaneous Measurement of Electric Field and Strain With a Tandem-Interferometric Device
Li, X., Zhang, Y., Zhou, X., & Cai, L. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2789098 · Cited by 21
DC-Link Voltage Balancing Modulation for Cascaded H-Bridge Converters
Ko, Y., Tcai, A., & Liserre, M. (2021) · IEEE Access · doi:10.1109/access.2021.3098896 · Cited by 20
“2 and 3 [19], where the number of loops is determined by the number of cells.”
BackgroundInsulation Design on High-Frequency Transformer for Solid-State Transformer
Li, Z., Hsieh, Y.-H., Li, Q., Lee, F. C., & Zhao, C. (2021) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce47101.2021.9595657 · Cited by 20
“Such an SST system can be used in the smart grid with the data center, electric vehicle fast-charging center applications, railway traction applications[1]-[5].”
Multiport Energy Router for DC Grid Clusters
Sun, L.-F., Jiang, W., Hashimoto, S., Lin, Z.-Y., & Kawaguchi, T. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3349420 · Cited by 17
“The first-generation energy router, leveraging a three-stage modular topology [16] and proposed by the FREEDM system center, supports wide voltage range conversion between an MV distribution grid, multiple 3 .”
MethodZhang, L., Sun, K., Huang, Z. W., & Li, Y. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310621 · Cited by 20
“However, cascaded multilevel converters in PV systems are different have not achieved such a success as in other industrial applications (motor drive and STATTCOM), which are connected with symmetrical individual dc sources [12]-[15].”
BackgroundYun, H.-J., Jeong, D.-K., Kim, H.-S., Kim, M., Baek, J.-W., Kim, J.-Y., & Kim, H. (2018) · Electronics · doi:10.3390/electronics7050062 · Cited by 20
“[20], based on a single-phase d–q control, a voltage balancing controller that adjusts the individual modulation signals is proposed to balance the DC-links.”
BackgroundAnurag, A., Acharya, S., Prabowo, Y., Jakka, V. N., & Bhattacharya, S. (2018) · European Conference on Cognitive Ergonomics · doi:10.1109/ecce.2018.8557388 · Cited by 18
“They are generally sensitive to harmonics, requires additional circuitry for protection and overloads, unable to control power flow, and performance under dcoffseted loads [4]–[6].”
BackgroundSelf-citationTian, J., Mao, C., Wang, D., Lu, J., Liang, X., & Liu, Y. (2015) · IET Electric Power Applications · doi:10.1049/iet-epa.2014.0287 · Cited by 20
Xu, P., He, X., Han, P., Guo, A., Shu, Z., & Gao, S. (2016) · Energies · doi:10.3390/en9100803 · Cited by 20
“In [17,18], the modulation waves are adjusted by proportional-integral (PI) controller for balancing the voltage.”
BackgroundSolid state transformer technologies and applications: A bibliographical survey
Adabi, M. E., Universitat Politecnica de Catalunya, B., & Martinez-Velasco, J. A. (2018) · AIMS energy · doi:10.3934/energy.2018.2.291 · Cited by 20
“Reference [68] presented a cascaded H-bridge converter-based SST to interface a 7.”
Zhao, H., Zhu, T., Cheng, D., Li, B., Ding, J., & Li, Y. (2017) · The Journal of Engineering · doi:10.1049/joe.2017.0656 · Cited by 19
Metadata
- Authors
- Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q.
- Affiliations
- Eaton (United States) (US)
- North Carolina State University (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-04
- Volume
- 28
- Issue
- 4
- Pages
- 1523-1532
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1999302015
- Cited by
- 642
- References
- 22
- Citations by year
- 2026: 23 · 2025: 41 · 2024: 51 · 2023: 47 · 2022: 63 · 2021: 40 · 2020: 59 · 2019: 70 · 2018: 56 · 2017: 63 · 2016: 44 · 2015: 29 · 2014: 37 · 2013: 19
- FWCI
- 17.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- solid-state transformer, cascaded H-bridge converter, dual active bridge converter, DC-link voltage balancing, power balancing, AC-DC rectifier, DC distribution systems, d-q model, power constraints, parallel converter modules
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.