The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Distribution Voltage Control for DC Microgrids Using Fuzzy Control and Gain-Scheduling Technique
Abstract
Installation of many distributed generations (DGs) could be detrimental to the power quality of utility grids. Microgrids facilitate effortless installation of DGs in conventional power systems. In recent years, dc microgrids have gained popularity because dc output sources such as photovoltaic systems, fuel cells, and batteries can be interconnected without ac/dc conversion, which contributes to total system efficiency. Moreover, high-quality power can be supplied continuously when voltage sags or blackouts occur in utility grids. We had already proposed a “low-voltage bipolar-type dc microgrid” and described its configuration, operation, and control scheme, through experiments. In the experiments, we used one energy storage unit with a dc/dc converter to maintain the dc-bus voltage under intentional islanding operation. However, dc microgrids should have two or more energy storage units for system redundancy. Therefore, we modified the system by adding another energy storage unit to our experimental system. Several kinds of droop controls have been proposed for parallel operations, some of which were applied for ac or dc microgrids. If a gain-scheduling control scheme is adopted to share the storage unit outputs, the storage energy would become unbalanced. This paper therefore presents a new voltage control that combines fuzzy control with gain-scheduling techniques to accomplish both power sharing and energy management. The experimental results show that the dc distribution voltages were within 340 V ± 5%, and the ratios of the stored energy were approximately equal, which implies that dc voltage regulation and stored energy balancing control can be realized simultaneously.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Progress in electrical energy storage system: a critical review
Chen, H., Cong, T. N., Yang, W., Tan, C., Li, Y., & Ding, Y. (2009) · Progress in Natural Science · doi:10.1016/j.pnsc.2008.07.014 · Cited by 3,746
Mohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Low-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution
Kakigano, H., Miura, Y., & Ise, T. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2077682 · Cited by 995
Self-citationAlajmi, B. N., Ahmed, K. H., Finney, S. J., & Williams, B. W. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2090903 · Cited by 635
Dynamic Behavior and Stabilization of DC Microgrids With Instantaneous Constant-Power Loads
Kwasinski, A., & Onwuchekwa, C. N. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2091285 · Cited by 626
DC microgrid based distribution power generation system
Ito, Y., Yang, Z., & Akagi, H. (2004) · International Power Electronics and Motion Control Conference · Cited by 383
Kwasinski, A. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2102774 · Cited by 288
Tenti, P., Paredes, H. K. M., & Mattavelli, P. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2093153 · Cited by 262
SiC Power Devices for Microgrids
Zhang, Q., Callanan, R., Das, M. K., Ryu, S.-H., Agarwal, A. K., & Palmour, J. W. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2079956 · Cited by 179
Wu, T., Sun, K.-H., Kuo, C.-L., & Chang, C. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2087773 · Cited by 124
Bus Selection in Multibus DC Microgrids
Balog, R. S., & Krein, P. T. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2094208 · Cited by 117
Kakigano, H., Miura, Y., Ise, T., Momose, T., & Hayakawa, H. (2008) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2008.4596210 · Cited by 105
Self-citationHatziargyriou, N. D. (2008) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.920383 · Cited by 96
Design of parallel sources in DC distributed power systems by using gain-scheduling technique
ye, Z., Boroyevich, D., Xing, K., & Lee, F. C. (2003) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1999.788997 · Cited by 54
Cited by
DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Lu, X., Guerrero, J. M., Sun, K., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2266419 · Cited by 1,049
Overview of Power Management Strategies of Hybrid AC/DC Microgrid
Nejabatkhah, F., & Li, Y. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2384999 · Cited by 986
Distributed Cooperative Control of DC Microgrids
Nasirian, V., Moayedi, S., Davoudi, A., & Lewis, F. L. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2324579 · Cited by 971
Metadata
- Authors
- Kakigano, H., Miura, Y., & Ise, T.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-05
- Volume
- 28
- Issue
- 5
- Pages
- 2246-2258
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2111965280
- Cited by
- 391
- References
- 15
- FWCI
- 41.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.