A Steady-State Analysis Method for a Modular Multilevel Converter
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Modular multilevel converters (MMC) are considered a top converter alternative for voltage-source converter (VSC) high-voltage, direct current (HVDC) applications. Main circuit design and converter performance evaluation are always important issues to consider before installing a VSC-HVDC system. Investigation into a steady-state analysis method for an MMC-based VSC-HVDC system is necessary. This paper finds a circular interaction among the electrical quantities in an MMC. Through this circular interaction, a key equation can be established to solve the unknown circulating current. A new steady-state model is developed to simply and accurately describe the explicit analytical expressions for various voltage and current quantities in an MMC. The accuracy of the expressions is improved by the consideration of the circulating current when deriving all the analytical expressions. The model's simplicity is demonstrated by having only one key equation to solve. Based on the analytical expressions for the arm voltages, the equivalent circuits for MMC are proposed to improve the current understanding of the operation of MMC. The feasibility and accuracy of the proposed method are verified by comparing its results with the simulation and experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216
Control and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Dynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188
Classification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172
Modulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
Marquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773
HVDC Connection of Offshore Wind Farms to the Transmission System
Bresesti, P., Kling, W. L., Hendriks, R. L., & Vailati, R. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.889624 · Cited by 750
Gnanarathna, U. N., Gole, A. M., & Jayasinghe, R. P. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2060737 · Cited by 739
Cited by
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
A Review of Architectures and Concepts for Intelligence in Future Electric Energy Systems
Strasser, T., Andren, F., Kathan, J., Cecati, C., Buccella, C., Siano, P., Leitao, P., Zhabelova, G., Vyatkin, V., Vrba, P., et al. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2361486 · Cited by 572
Design and Operation of a Hybrid Modular Multilevel Converter
Zeng, R., Xu, L., Yao, L., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320822 · Cited by 455
Analysis and Control of Modular Multilevel Converters With Integrated Battery Energy Storage
Vasiladiotis, M., & Rufer, A. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2303297 · Cited by 402
Isolated DC/DC Structure Based on Modular Multilevel Converter
Kenzelmann, S., Rufer, A., Dujic, D., Canales, F., & de Novaes, Y. R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2305976 · Cited by 371
Gowaid, I. A., Adam, G. P., Massoud, A. M., Ahmed, S., Holliday, D., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2306453 · Cited by 356
Zhang, M., Huang, L., Yao, W., & Lu, Z. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2269140 · Cited by 292
Sequence Impedance Modeling of Modular Multilevel Converters
Sun, J., & Liu, H. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2762408 · Cited by 287
Fault Detection and Localization Method for Modular Multilevel Converters
Deng, F., Chen, Z., Khan, M. R., & Zhu, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2348194 · Cited by 266
Design and Control of Modular Multilevel Converters for Battery Electric Vehicles
Quraan, M., Yeo, T., & Tricoli, P. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2408435 · Cited by 204
“Alternatively, a single coupled inductor could be used for the same function [9], [12], [13].”
BackgroundGong, Z., Wu, X., Dai, P., & Zhu, R. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2844836 · Cited by 106
Steady-State Modeling of Modular Multilevel Converter Under Unbalanced Grid Conditions
Shi, X., Wang, Z., Liu, B., Li, Y., Tolbert, L. M., & Wang, F. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2629472 · Cited by 73
“In summary, compared to [37], the steady-state model under unbalanced conditions is more complicated, especially when negative-sequence phase current control is adopted.”
BackgroundA Postfault Strategy to Control the Modular Multilevel Converter Under Submodule Failure
Yang, Q., Qin, J., & Saeedifard, M. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2449875 · Cited by 69
Zhao, F., Xiao, G., & Zhao, T. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2764950 · Cited by 23
Impact of grid-forming control on the internal energy of a modular multilevel converter
Rokrok, E., Qoria, T., Bruyere, A., Francois, B., Zhang, H., Belhaouane, M., & Guillaud, X. (2020) · 2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe) · doi:10.23919/epe20ecceeurope43536.2020.9215646 · Cited by 19
The Predictive Closed-Loop Averaging Control of MMC Phase-Unit Losses Under Unbalanced Conditions
Xu, J., Yu, Y., & Zhao, C. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2868772 · Cited by 14
Metadata
- Authors
- Song, Q., Liu, W., Li, X., Rao, H., Xu, S., & Li, L.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-08
- Volume
- 28
- Issue
- 8
- Pages
- 3702-3713
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2007244578
- Cited by
- 503
- References
- 17
- FWCI
- 18.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.