A High Step-Up Three-Port DC–DC Converter for Stand-Alone PV/Battery Power Systems
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
A three-port dc-dc converter integrating photovoltaic (PV) and battery power for high step-up applications is proposed in this paper. The topology includes five power switches, two coupled inductors, and two active-clamp circuits. The coupled inductors are used to achieve high step-up voltage gain and to reduce the voltage stress of input side switches. Two sets of active-clamp circuits are used to recycle the energy stored in the leakage inductors and to improve the system efficiency. The operation mode does not need to be changed when a transition between charging and discharging occurs. Moreover, tracking maximum power point of the PV source and regulating the output voltage can be operated simultaneously during charging/discharging transitions. As long as the sun irradiation level is not too low, the maximum power point tracking (MPPT) algorithm will be disabled only when the battery charging voltage is too high. Therefore, the control scheme of the proposed converter provides maximum utilization of PV power most of the time. As a result, the proposed converter has merits of high boosting level, reduced number of devices, and simple control strategy. Experimental results of a 200-W laboratory prototype are presented to verify the performance of the proposed three-port converter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Comprehensive Approach to Modeling and Simulation of Photovoltaic Arrays
Villalva, M. G., Gazoli, J. R., & Filho, E. R. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2013862 · Cited by 4,390
Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications
Li, W., & He, X. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049715 · Cited by 1,423 · cited 1×
“It is studied that for the dc–dc converters connected to the solar panels, voltage gain extension cells such as coupled inductors, transformers, and switched capacitors are often employed to achieve high voltage conversion ratios [3].”
BackgroundDevelopment of a photovoltaic arraymodel for use in power-electronics simulation studies
Gow, J. A., & Manning, C. D. (1999) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19990116 · Cited by 1,104 · cited 1×
“This model provides a tradeoff between accuracy and complexity [33].”
MethodAn Isolated Three-Port Bidirectional DC-DC Converter With Decoupled Power Flow Management
Zhao, C., Round, S. D., & Kolar, J. W. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002056 · Cited by 900
A multiple-input DC-DC converter topology
Dobbs, B. G., & Chapman, P. L. (2003) · IEEE Power Electronics Letters · doi:10.1109/lpel.2003.813481 · Cited by 511
Design of Multiple-Input Power Converter for Hybrid Vehicles
Solero, L., Lidozzi, A., & Pomilio, J. A. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.854020 · Cited by 478
Transformer-Coupled Multiport ZVS Bidirectional DC–DC Converter With Wide Input Range
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915129 · Cited by 478
Boost Converter With Coupled Inductors and Buck–Boost Type of Active Clamp
Wu, T.-F., Lai, Y.-S., Hung, J.-C., & Chen, Y.-M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.903925 · Cited by 425
Self-citationKrishnaswami, H., & Mohan, N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022756 · Cited by 411
Cited by
Forouzesh, M., Siwakoti, Y. P., Gorji, S. A., Blaabjerg, F., & Lehman, B. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2652318 · Cited by 2,123
Review of Multiport Converters for Solar and Energy Storage Integration
Bhattacharjee, A. K., Kutkut, N., & Batarseh, I. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2830788 · Cited by 423
Raghavendra, K. V. G., Zeb, K., Muthusamy, A., Krishna, T. N. V., Kumar, S. V. S. V. P., Kim, D.-H., Kim, M.-S., Cho, H.-G., & Kim, H.-J. (2019) · Electronics · doi:10.3390/electronics9010031 · Cited by 269
A New Three Input DC/DC Converter for Hybrid PV/FC/Battery Applications
Kardan, F., Alizadeh, R., & Banaei, M. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2731816 · Cited by 200
“In [28], a two-input grid-connected high step-up dc/dc converter is proposed.”
BackgroundDebnath, D., & Chatterjee, K. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2379584 · Cited by 177
Wali, S. B., Hannan, M. A., Reza, M. S., Ker, P. J., Begum, R. A., Rahman, M. S. A., & Mansor, M. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.102296 · Cited by 149
Metadata
- Authors
- Chen, Y.-M., Huang, A. Q., & Yu, X.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-11
- Volume
- 28
- Issue
- 11
- Pages
- 5049-5062
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2153155243
- Cited by
- 305
- References
- 29
- FWCI
- 13.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.