State Observer-Based Sensor Fault Detection and Isolation, and Fault Tolerant Control of a Single-Phase PWM Rectifier for Electric Railway Traction
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
This paper presents an easy and a robust sensor fault detection and isolation (FDI) and fault tolerant control (FTC) of a single phase PWM rectifier for electrical railway traction application. Catenary current sensor and dc link voltage sensor failures are considered. The FDI method is based on observers and residual generation. The different FDI algorithm steps allow a good detection and isolation of the sensor fault and identify the faulty sensor. The reconfiguration strategy consists of two steps with open loop control and closed loop control working. Simulation results are presented to illustrate the good performance of the FTC procedure. Experimental results are also presented to show the effectiveness of the proposed FDI and FTC algorithms and good performances of the rectifier after the reconfiguration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luenberger, D. (1971) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1971.1099826 · Cited by 2,709 · cited 1×
“In this paper, Luenberger state observer [40], [41] is used for the dc link voltage Vdc and catenary current iC estimation.”
MethodRodríguez, P., Luna, A., Muñoz-Aguilar, R. S., Etxeberria-Otadui, I., Teodorescu, R., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159242 · Cited by 681 · cited 6×
“The reference current i∗C is expressed by i∗C = IC √ 2 sin (θg ) IC √ 2 = ild + iPI (4) where iPI is the output of the dc bus voltage PI controller, and θg is the phase angle obtained using the SOGI-QSG-FLL modules as described below.”
MethodInfluentialEffect of model uncertainty on failure detection: the threshold selector
Emami-Naeini, A., Akhter, M. M., & Rock, S. M. (1988) · IEEE Transactions on Automatic Control · doi:10.1109/9.14432 · Cited by 427 · cited 1×
“The threshold value is carefully chosen to minimize as much as possible the false alarm rate due to system parameter variations, operating points variation or noises [42] and [43].”
BackgroundActive Power Decoupling for High-Power Single-Phase PWM Rectifiers
Li, H., Zhang, K., Zhao, H., Fan, S., & Xiong, J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2208764 · Cited by 318
Jung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
Najafabadi, T. A., Salmasi, F. R., & Jabehdar-Maralani, P. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2055775 · Cited by 250 · cited 1×
“In [30], an adaptive phase currents and rotor resistance observer is performed for position sensor, phase currents, and dc-link voltage sensors in induction motor drives.”
MethodFPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems
Karimi, S., Gaillard, A., Poure, P., & Saadate, S. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005244 · Cited by 245 · cited 2×
“WECS have been widely concerned by these investigations, as well as DFIG-based systems [27], [28] as PMSG-based ones [29].”
BackgroundVector Control of Single-Phase Voltage-Source Converters Based on Fictive-Axis Emulation
Bahrani, B., Rufer, A., Kenzelmann, S., & Lopes, L. A. C. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2101992 · Cited by 206
Easy and Fast Sensor Fault Detection and Isolation Algorithm for Electrical Drives
Berriri, H., Naouar, M. W., & Slama-Belkhodja, I. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2140333 · Cited by 197
Self-citationManipulator Fault Diagnosis via Higher Order Sliding-Mode Observers
Capisani, L. M., Ferrara, A., de Loza, A. F., & Fridman, L. M. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2189534 · Cited by 176 · cited 1×
“The threshold value is carefully chosen to minimize as much as possible the false alarm rate due to system parameter variations, operating points variation or noises [42] and [43].”
Background
Cited by
Chen, H., Jiang, B., Ding, S. X., & Huang, B. (2022) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2020.3029946 · Cited by 521
A Digital Twin Approach for Fault Diagnosis in Distributed Photovoltaic Systems
Jain, P., Poon, J., Singh, J. P., Spanos, C., Sanders, S. R., & Panda, S. K. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2911594 · Cited by 462
A Review of Fault Detection and Diagnosis for the Traction System in High-Speed Trains
Chen, H., & Jiang, B. (2020) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2019.2897583 · Cited by 413
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“Some techniques are proposed in [44]–[47] for detection and isolation of several sensor types, namely current, voltage, and speed sensors.”
MethodWang, T., Xu, H., Han, J., Elbouchikhi, E., & Benbouzid, M. E. H. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2393373 · Cited by 273
Model-Based Fault Detection and Identification for Switching Power Converters
Poon, J., Jain, P., Konstantakopoulos, I. C., Spanos, C., Panda, S. K., & Sanders, S. R. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2541342 · Cited by 257
Gou, B., Xu, Y., Xia, Y., Deng, Q., & Ge, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2994351 · Cited by 211
Gou, B., Ge, X., Wang, S., Feng, X., Kuo, J. B., & Habetler, T. G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465299 · Cited by 191
“tolerant control method based on a state observer for the sensors in a single-phase rectifier has been proposed in [29].”
MethodCurrent Sensor Fault Diagnosis and Tolerant Control for VSI-Based Induction Motor Drives
Yu, Y., Zhao, Y., Wang, B., Huang, X., & Xu, D. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2713482 · Cited by 189
“In [11]–[16], the measured currents are compared with the estimated currents in order to localize the faulty current sensor.”
BackgroundShu, C., Ya-Ting, C., Tian-Jian, Y., & Xun, W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2535960 · Cited by 158
Ge, X., Pu, J., Gou, B., & Liu, Y.-C. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2691804 · Cited by 158
Robust Sensors-Fault-Tolerance With Sliding Mode Estimation and Control for PMSM Drives
Kommuri, S. K., Lee, S. B., & Veluvolu, K. C. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2783888 · Cited by 140
“above approach, a time-based analysis [29], [30] is introduced to guarantee the robustness against false detection.”
BackgroundBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Metadata
- Authors
- Youssef, A. B., El Khil, S. K., & Slama-Belkhodja, I.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-12
- Volume
- 28
- Issue
- 12
- Pages
- 5842-5853
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2038419241
- Cited by
- 186
- References
- 25
- FWCI
- 15.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.