Postfault Operation of an Asymmetrical Six-Phase Induction Machine With Single and Two Isolated Neutral Points
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
The paper presents a study of postfault control for an asymmetrical six-phase induction machine with single and two isolated neutral points, during single open-phase fault. Postfault control is based on the normal decoupling (Clarke) transformation, so that reconfiguration of the controller is minimized. Effect of the single open-phase fault on the machine equations under this control structure is discussed. Different modes of postfault operation are analyzed and are further compared in terms of the achievable torque and stator winding losses. Validity of the analysis is verified using experimental results obtained from a six-phase induction motor drive prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiphase Electric Machines for Variable-Speed Applications
Levi, E. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918488 · Cited by 2,157
Self-citationDisturbance-free operation of a multiphase current-regulated motor drive with an opened phase
Fu, J.-R., & Lipo, T. A. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.315238 · Cited by 372
Disturbance free operation of a multiphase current regulated motor drive with an opened phase
Fu, J.-R., & Lipo, T. A. (2002) · Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting · doi:10.1109/ias.1993.298884 · Cited by 318
Fault-Tolerant Interior-Permanent-Magnet Machines for Hybrid Electric Vehicle Applications
Parsa, L., & Toliyat, H. A. (2007) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2007.896978 · Cited by 317
Fault-Tolerant Control of Five-Phase Permanent-Magnet Motors With Trapezoidal Back EMF
Dwari, S., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2045322 · Cited by 289
Kianinezhad, R., Nahid-Mobarakeh, B., Baghli, L., Betin, F., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918479 · Cited by 266
An Optimal Control Technique for Multiphase PM Machines Under Open-Circuit Faults
Dwari, S., & Parsa, L. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.920643 · Cited by 244
Fuzzy Logic and Sliding-Mode Controls Applied to Six-Phase Induction Machine With Open Phases
Fnaiech, M. A., Betin, F., Capolino, G.-A., & Fnaiech, F. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2034285 · Cited by 227
Modeling and control of a multi-phase induction machine with structural unbalance
Zhao, Y., & Lipo, T. A. (1996) · IEEE Transactions on Energy Conversion · doi:10.1109/60.537028 · Cited by 216
Modeling and control of a multi-phase induction machine with structural unbalance
Zhao, Y., & Lipo, T. A. (1996) · IEEE Transactions on Energy Conversion · doi:10.1109/60.537009 · Cited by 198
Ryu, H.-M., Kim, J.-W., & Sul, S.-K. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.876074 · Cited by 187
Analysis and Tests of a Dual Three-Phase 12-Slot 10-Pole Permanent-Magnet Motor
Barcaro, M., Bianchi, N., & Magnussen, F. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2070784 · Cited by 173
Shamsi-Nejad, M.-A., Nahid-Mobarakeh, B., Pierfederici, S., & Meibody-Tabar, F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918485 · Cited by 160
Mohammadpour, A., & Parsa, L. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2223717 · Cited by 158
Parker, M. A., Ran, L., & Finney, S. J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2186774 · Cited by 155
Experimental Tests of Dual Three-Phase Induction Motor Under Faulty Operating Condition
Alberti, L., & Bianchi, N. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2171175 · Cited by 138
Analysis and tests of a dual three-phase 12-slot 10-pole permanent magnet motor
Barcaro, M., Bianchi, N., & Magnussen, F. (2009) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2009.5316094 · Cited by 127
Impact of Stator Winding of a Five-Phase Permanent-Magnet Motor on Postfault Operations
Bianchi, N., Bolognani, S., & Pré, M. D. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.920645 · Cited by 121
Safety-critical design of electromechanical actuation systems in commercial aircraft
Bennett, J. W., Mecrow, B. C., Atkinson, D. J., & Atkinson, G. J. (2011) · IET Electric Power Applications · doi:10.1049/iet-epa.2009.0304 · Cited by 111
Baudart, F., Dehez, B., Matagne, E., Telteu-Nedelcu, D., Alexandre, P., & Labrique, F. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2170393 · Cited by 98
Fault-Tolerant Control for a Modular Generator–Converter Scheme for Direct-Drive Wind Turbines
Parker, M. A., Ng, C., & Ran, L. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2045318 · Cited by 97
Lin, F., Hung, Y., Hwang, J., & Tsai, M.-T. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2224888 · Cited by 87
Ruba, M., & Fodorean, D. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2226419 · Cited by 48
Fault tolerant multiphase electrical drives: the impact of design
Semail, E., Kestelyn, X., & Locment, F. (2008) · The European Physical Journal Applied Physics · doi:10.1051/epjap:2008057 · Cited by 22
Fault-tolerant control strategies for quad inverter induction motor drives with one failed inverter
Grandi, G., Sanjeevikumar, P., Gritli, Y., & Filippetti, F. (2012) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2012.6349992 · Cited by 20
Cited by
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part I
Barrero, F., & Duran, M. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2447733 · Cited by 927
Self-citationRecent Advances in the Design, Modeling, and Control of Multiphase Machines—Part II
Duran, M. J., & Barrero, F. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2448211 · Cited by 658
Self-citationA Review on Multiphase Drives for Automotive Traction Applications
Salem, A., & Narimani, M. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2956355 · Cited by 311
A Unified Analysis of the Fault Tolerance Capability in Six-Phase Induction Motor Drives
Munim, W. N. W. A., Duran, M. J., Che, H. S., Bermudez, M., Gonzalez-Prieto, I., & Rahim, N. A. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2632118 · Cited by 292
Self-citationGuzman, H., Duran, M. J., Barrero, F., Bogado, B., & Toral, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2289882 · Cited by 258
Self-citation
Metadata
- Authors
- Che, H. S., Duran, M. J., Levi, E., Jones, M., Hew, W.-P., & Rahim, N. A.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-10
- Volume
- 29
- Issue
- 10
- Pages
- 5406-5416
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2020612414
- Cited by
- 394
- References
- 25
- FWCI
- 16.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.