An Improved Control System for Modular Multilevel Converters with New Modulation Strategy and Voltage Balancing Control
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Modular multilevel converter (MMC) has become one of the most promising converter topologies for future high-power applications. A challenging issue of the MMC is the voltage balancing among arm capacitors. A good overall control system is also vital for the MMC, which should be based on sound mathematical model, readily adaptable for different applications, and capable of high performance. This paper presents a general control structure for MMC inverters, which is suitable for both voltage-based and energy-based control methods, and includes voltage balancing between the upper and lower arms. A new method for voltage balancing among arm capacitors, which is based on an improved pulse-width modulation, is also presented. The proposed method avoids some major disadvantages found in present voltage balancing methods, such as dependence on computation-intensive voltage sorting algorithms, extra switching actions, interference with output voltage, etc. Furthermore, all switching actions are evenly distributed among power devices. The proposed control system as a whole can serve as a promising solution for practical applications, especially when the number of submodules is fairly high. Simulation and experimental results verify the effectiveness of the proposed methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872 · cited 1×
“R ECENTLY, multilevel converters have attracted growing attentions and found themselves in increasing market of high power and high/medium voltage applications [1], [2], such as high-voltage dc transmission (HVDC), flexible ac transmission systems (FACTS), industrial motor drives, utility-scale renewable energy system…”
BackgroundAn innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385 · cited 1×
“R ECENTLY, multilevel converters have attracted growing attentions and found themselves in increasing market of high power and high/medium voltage applications [1], [2], such as high-voltage dc transmission (HVDC), flexible ac transmission systems (FACTS), industrial motor drives, utility-scale renewable energy system…”
BackgroundControl and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565 · cited 1×
“21 gives the spectral analysis of the line voltage with and without load.”
BackgroundTu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Classification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172 · cited 1×
“The distributed methods keep the voltage of each capacitor close to its reference value through closed-loop control, and usually with carrier phase-shifted pulse-width modulation (CPSPWM) [13]–[15].”
MethodModulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934
On dynamics and voltage control of the Modular Multilevel Converter
Antonopoulos, A., Ängquist, L., & Nee, H. (2009) · European Conference on Power Electronics and Applications · Cited by 831
Ilves, K., Antonopoulos, A., Norrga, S., & Nee, H.-P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159809 · Cited by 578
Hagiwara, M., Maeda, R., & Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2089065 · Cited by 392 · cited 1×
“Some typical control methods have already been proposed in the literatures, such as average control [13], arm-balancing control [14], and circulating current control [19].”
Method
Cited by
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
“The reference value of circulating current controller is generated using a differential voltage controller (arm capacitor voltage control) [139].”
Control of arm capacitor voltages in modular multilevel converters
Lizana, R., Perez, M. A., Bernet, S., Espinoza, J. R., & Rodriguez, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2426183 · Cited by 70
“There are several control strategies presented in the literature to perform this balance based on energy models , separating the total and differential energy [17], calculating the energies in row, columns and diagonals [18] and also splitting the energy of the arms per phases and upper and lower side [19], [20].”
BackgroundNew Measuring Technique for Reducing the Number of Voltage Sensors in Modular Multilevel Converters
Picas, R., Zaragoza, J., Pou, J., Ceballos, S., & Balcells, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2412658 · Cited by 62
Capacitor Voltage Estimation Scheme With Reduced Number of Sensors for Modular Multilevel Converters
Abushafa, O. S. M., Gadoue, S. M., Dahidah, M. S. A., Atkinson, D. J., & Missailidis, P. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2797245 · Cited by 53
Tai, B., Gao, C., Liu, X., & Chen, Z. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2535463 · Cited by 46
A Three-Level Modular DC/DC Converter Applied in High Voltage DC Grid
You, H., & Cai, X. (2018) · IEEE Access · doi:10.1109/access.2018.2829703 · Cited by 34
Wang, J., & Wang, P. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2870352 · Cited by 32
Metadata
- Authors
- Fan, S., Zhang, K., Xiong, J., & Xue, Y.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-01
- Volume
- 30
- Issue
- 1
- Pages
- 358-371
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2334341540
- Cited by
- 198
- References
- 23
- FWCI
- 15.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.