Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
This paper addresses the harmonic stability caused by the interactions among the wideband control of power converters and passive components in an ac power-electronics-based power system. The impedance-based analytical approach is employed and expanded to a meshed and balanced three-phase network which is dominated by multiple current- and voltage-controlled inverters with LCL- and LC-filters. A method of deriving the impedance ratios for the different inverters is proposed by means of the nodal admittance matrix. Thus, the contribution of each inverter to the harmonic stability of the power system can be readily predicted through Nyquist diagrams. Time-domain simulations and experimental tests on a three-inverter-based power system are presented. The results validate the effectiveness of the theoretical approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Self-citationModeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Self-citationImpedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Input filter considerations in design and application of switching regulators.
Middlebrook, R. D. (1976) · Medical Entomology and Zoology · Cited by 1,180
Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117
Enslin, J. H. R., & Heskes, P. J. M. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836615 · Cited by 824
Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001910 · Cited by 733
Cited by
Harmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282
Self-citationDefinition and Classification of Power System Stability – Revisited & Extended
Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., et al. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3041774 · Cited by 1,244
Microgrid Stability Definitions, Analysis, and Examples
Farrokhabadi, M., Canizares, C. A., Simpson-Porco, J. W., Nasr, E., Fan, L., Mendoza-Araya, P. A., Tonkoski, R., Tamrakar, U., Hatziargyriou, N., Lagos, D., et al. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2925703 · Cited by 752
Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview
Harnefors, L., Wang, X., Yepes, A. G., & Blaabjerg, F. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2490549 · Cited by 674
Self-citationVirtual-Impedance-Based Control for Voltage-Source and Current-Source Converters
Wang, X., Li, Y. W., Blaabjerg, F., & Loh, P. C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2382565 · Cited by 670
Self-citationImpedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters
Wen, B., Dong, D., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2419712 · Cited by 586
Wang, L., Qin, Z., Slangen, T., Bauer, P., & van Wijk, T. (2021) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2021.3054601 · Cited by 417
Wu, W., Liu, Y., He, Y., Chung, H. S.-H., Liserre, M., & Blaabjerg, F. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714143 · Cited by 397
Self-citationGrid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source Converters
Wang, X., Blaabjerg, F., & Loh, P. C. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2411851 · Cited by 375
Self-citationGandoman, F. H., Ahmadi, A., Sharaf, A. M., Siano, P., Pou, J., Hredzak, B., & Agelidis, V. G. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.062 · Cited by 345
Wang, X., Blaabjerg, F., & Loh, P. C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2361853 · Cited by 304
Self-citationCouplings in Phase Domain Impedance Modelling of Grid-Connected Converters
Bakhshizadeh, M. K., Wang, X., Blaabjerg, F., Hjerrild, J., Kocewiak, L., Bak, C. L., & Hesselbek, B. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2542244 · Cited by 302
Self-citationFrequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Lyu, J., Cai, X., & Molinas, M. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2498182 · Cited by 267
“Moreover, the Nyquist map is also able to demonstrate the impact of system parameters on stability, which has a great significance in designing a power electronics-based system [17].”
BackgroundMethodZhang, X., Xia, D., Fu, Z., Wang, G., & Xu, D. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2811718 · Cited by 262
Overview of Silicon Carbide Technology: Device, Converter, System, and Application
Wang, F. (., & Zhang, Z. (2016) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2016.00003 · Cited by 204
“2) System Stability Enhancement Multiple renewable energy and energy storage interface converters in microgrids, connected to relatively weak grids, can lead to harmonic resonance and stability issues [85], [86].”
BackgroundHarmonic Instability in MMC-HVDC Converters Resulting From Internal Dynamics
Li, T., Gole, A. M., & Zhao, C. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2542188 · Cited by 184
“Similar phenomenon was also reported in 2-level voltage source converters [8].”
ResultGao, F., Bozhko, S., Costabeber, A., Asher, G., & Wheeler, P. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2711552 · Cited by 178
“impedance of the load system [17]–[20].”
Power electronics - the key technology for renewable energy system integration
Blaabjerg, F., Yang, Y., Ma, K., & Wang, X. (2015) · 2015 International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2015.7418680 · Cited by 148
“Characterizing the dynamics of grid-connected converters at the different time/frequency scales within the various operating scenarios are getting more important for developing control strategies [51].”
BackgroundSelf-citationRobust Stability Analysis of Synchronverters Operating in Parallel
Rosso, R., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896707 · Cited by 117
Robust Stability Analysis of LCL Filter Based Synchronverter Under Different Grid Conditions
Rosso, R., Cassoli, J., Buticchi, G., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2867040 · Cited by 89
“Pole placement at prescribed locations in order to achieve desired dynamic has been proposed as optimal tuning procedure [11], [12] and eigenvalue analysis is the commonly adopted approach for investigation of stability of gridconnected converters and design purposes [13].”
BackgroundAnalysis and Stabilization of a Smart Transformer-Fed Grid
Zou, Z.-X., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2733450 · Cited by 41
“verter utilizes measured voltage feedforward (blue curve), the influence of the ST output filter is introduced and the connected DER inverters are subject to both resonance issue and harmonic instability [18], represented by oscillation and low-order harmonic distortion.”
BackgroundImpedance modeling of modular multilevel converters by harmonic linearization
Lyu, J., Chen, Q., & Cai, X. (2016) · 2016 IEEE 17th Workshop on Control and Modeling for Power Electronics (COMPEL) · doi:10.1109/compel.2016.7556719 · Cited by 20
Metadata
- Authors
- Wang, X., Blaabjerg, F., & Wu, W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2014-12
- Volume
- 29
- Issue
- 12
- Pages
- 6421-6432
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2124074876
- Cited by
- 785
- References
- 21
- FWCI
- 36.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.