Design and Operation of a Hybrid Modular Multilevel Converter
The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Abstract
This paper presents a hybrid modular multilevel converter (MMC), which combines full-bridge submodules (FBSM) and half-bridge submodules (HBSM). Compared with the FBSM-based MMC, the proposed topology has the same dc fault blocking capability but uses fewer power devices hence has lower power losses. To increase power transmission capability of the proposed hybrid MMC, negative voltage states of the FBSMs are adopted to extend the output voltage range. The optimal ratio of FBSMs and HBSMs, and the number of FBSMs generating a negative voltage state are calculated to ensure successful dc fault blocking and capacitor voltage balancing. Equivalent circuits of each arm consisting of two individual voltage sources are proposed and two-stage selecting and sorting algorithms for ensuring capacitor voltage balancing are developed. Comparative studies for different circuit configurations show excellent performance balance for the proposed hybrid MMC, when considering dc fault blocking capability, power losses, and device utilization. Experimental results during normal operation and dc fault conditions demonstrate feasibility and validity the proposed hybrid MMC.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The blocking of a dc fault in an MMC can be achieved when the total voltage of connected submodules along the fault current path is greater than the line-to-line ac voltage [111].”
From Modular Multilevel Converters: Recent Achievements and Challenges (2021) · cites this paper as [111]
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundTu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Self-citationDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 3×
“Thus, in contrast to the conventional capacitor voltage balancing algorithm [2], in which only capacitor voltage and arm current direction are used for SM selection, the selection of SMs in the hybrid MMC has to consider the differences in their behavior, and charging and discharging periods between the FBSMs and HBSM…”
BackgroundMethodResultModulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934 · cited 2×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundMethodShort-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790 · cited 1×
“However, an HBSM-based MMC (HB-MMC) does not have dc fault blocking capability, thus relies on ac or dc circuit breakers to isolate dc faults [13], [14].”
BackgroundMarquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundIlves, K., Antonopoulos, A., Norrga, S., & Nee, H.-P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159809 · Cited by 578 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundA Steady-State Analysis Method for a Modular Multilevel Converter
Song, Q., Liu, W., Li, X., Rao, H., Xu, S., & Li, L. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227818 · Cited by 503 · cited 2×
“A detailed analysis on the impact of the circulating current on capacitor voltage ripple is provided in [23].”
Background
Research works printed but not linked: 1
- backlund, 2012, Data sheet IGBT module 5SNA 1200G450300
Cited by
Items 201–300 of 455
Donoso, F., Cárdenas, R., Espinoza, M., Clare, J., Mora, A., & Watson, A. J. (2021) · IEEE Access · doi:10.1109/access.2021.3054340 · Cited by 11
“The main drawback of the methods discussed in [13], [21], [23], [24] is that the feed-forward circulating currents are calculated off-line and are imposed without considering the degree of imbalance between the capacitor voltages of the FBSMs and HBSMs, i.”
BackgroundInfluentialFlexible AC Transmission Systems
Watanabe, E. H., Lima, F. K. D. A., Dias, R. F. S., Aredes, M., Barbosa, P. G., & Barcelos, S. L. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99216-9.00038-x · Cited by 11
Li, R., Fletcher, J., Yao, L., & Williams, B. W. (2016) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2015.0302 · Cited by 11
Self-citationFault blocking converters for HVDC transmission: a transient behaviour comparison
Vozikis, D., Rault, P., Holliday, D., & Finney, S. J. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8151 · Cited by 10
Li, Y., Guo, P., Hu, J., Xu, Q., & Jia, Y. (2023) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109589 · Cited by 12
Daoud, M., Massoud, A. M., Elserougi, A. A., Abdel-Khalik, A. S., & Ahmed, S. (2017) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec.2017.8333606 · Cited by 10
“A Hybrid Boost MMC was proposed in [13] where the number of FB SMs is twice the number of HB SMs (FB:HB = 2:1), providing the same performance of the FB-based Boost MMC with a reduced number of switching devices.”
BackgroundMethodZhang, Y., Zhang, J., Deng, F., & Din, Z. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108053 · Cited by 11
State-space model and PQ operating zone analysis of hybrid MMC
Lu, X., Xiang, W., Lin, W., & Wen, J. (2018) · Electric Power Systems Research · doi:10.1016/j.epsr.2018.05.003 · Cited by 10
“Recently, there has been increasing attention on the topology, sub-module ratio design and the control strategy of the hybrid MMC[8]-[14].”
BackgroundWang, K., Song, Q., & Sun, Q. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.110057 · Cited by 9
Motwani, J. K., Liu, J., Rao, A., Burgos, R. P., Boroyevich, D., Zhou, Z., Popovski, A., Beddingfield, R., Harzig, T., & Dong, D. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3440917 · Cited by 9
“Moreover, while hybrid-MMCs [15], [38] have recently gained practical usage due to their excellent dc fault clearance abilities, they are still not very common due to high losses, costs, and volume.”
BackgroundSolid-State Transformers: A Review—Part II: Modularity and Applications
Predescu, D.-M., & Rosu, S. G. (2025) · Technologies · doi:10.3390/technologies13020050 · Cited by 15
“…are the generation of a unipolar or, respectively, a bipolar voltage across the SM and better ride-through capabilities for the Full-Bridge SM (FB-SM) at the cost of an increased semi-conductor count [51,53] and number of states of the SM; Half-Bridge SMs have two states: charging and discharging.”
Effects of DC fault clearance methods on transients in a full-bridge monopolar MMC-HVDC link
Wenig, S., Goertz, M., Prieto, J., Suriyah, M., & Leibfried, T. (2016) · IEEE Innovative Smart Grid Technologies-Asia · doi:10.1109/isgt-asia.2016.7796496 · Cited by 9
“See a clamp double module (CDSM) in [2] and a hybrid MMC structure in [3].”
BackgroundAnalysis of submodule capacitor overvoltage during DC-side fault in hybrid MMC-based HVDC system
Gim, Y., Li, Z., Meng, J., Deng, Z., & Song, Q. (2019) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2019-ecceasia42246.2019.8797174 · Cited by 9
A smooth startup strategy for hybrid MMC based HVDC systems
Xu, L., Luo, Y., Song, Y., & Blaabjerg, F. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107315 · Cited by 9
Self-citationBasić, M., Utvic, M., & Dujić, D. (2021) · IEEE Access · doi:10.1109/access.2021.3118277 · Cited by 10
“Design of an H-MMC enabling both reduction of DC link voltage down to zero and DC fault handling capability, comprising 2/3 of FB SMs per branch, has been presented in [24], along with a control approach relying on a capacitor sorting algorithm.”
MethodEquivalent electromagnetic model of self-blocking MMC with DC fault isolation capability
Xiang, W., Lin, W., Wen, J., Yao, L., & Wang, Z. (2016) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2016.7741920 · Cited by 9
“A variety of SM topologies [1]-[4] and new breed of hybrid MMC [5]-[6] with DC fault blocking capability have been proposed.”
BackgroundSelf-citationYu, J., Burgos, R. P., Mehrabadi, N. R., & Boroyevich, D. (2017) · IEEE Electric Ship Technologies Symposium (ESTS) · doi:10.1109/ests.2017.8069256 · Cited by 9
“Although a negative output voltage of submodule is not essential in the normal operation, it could be utilized to increase the modulation index and ac output voltages [20].”
BackgroundXie, X., Li, H., Hu, Y., Yang, T., Wu, Y., & Chai, Z. (2019) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8921465 · Cited by 10
“Compared with half-bridge submodules (HBSMs), fullbridge submodules (FBSMs) have inherent advantages of dc fault ride-through capability to prevent the generator from high fault current [12], [13].”
BackgroundBieber, L. M., Wang, L., & Li, W. (2020) · IEEE Open Access Journal of Power and Energy · doi:10.1109/oajpe.2020.2976889 · Cited by 10
A Diode-MMC AC/DC Hub for Connecting Offshore Wind Farm and Offshore Production Platform
Huang, K., Xu, L., & Liu, G. (2021) · Energies · doi:10.3390/en14133759 · Cited by 9
“References [8,23] indicate that the valve power losses of the DR, HBSMs and FBSMs are approximately 0.”
BackgroundSelf-citationRamya, G., & Ramaprabha, R. (2015) · IEEE International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds.2015.7203503 · Cited by 10
Errigo, F., Venet, P., Chédot, L., & Sarı, A. (2018) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2018.8352449 · Cited by 9
Analysis and optimization of hybrid modular multilevel converters under over-modulation conditions
Hu, P., He, Z.-X., Yin, R., Guo, J., Guerrero, J. M., & Teodorescu, R. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105578 · Cited by 9
Zhao, C., Li, Y., Xu, F., Li, Z., Wang, P., & Lei, M. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096781 · Cited by 9
“In order to trade off power losses and fault ride through capability, the hybrid MMC mixed with HBSMs and FBSMs has been proposed and studied deeply in [14]-[15].”
BackgroundRaj, R., Elmouatamid, A., Swain, A., & Pong, P. W. T. (2025) · Energy Reports · doi:10.1016/j.egyr.2025.07.017 · Cited by 12
Black Start-Up Strategy of MMC in Series with Diode Rectifier Converter for Offshore Wind Farms
Wang, Z., Wang, J., Zhao, Z., Li, T., & Sheng, J. (2023) · IEEE International Power Electronics and Application Symposium (PEAS) · doi:10.1109/peas58692.2023.10395112 · Cited by 8
“When rated system DC voltage is ±320kV and rated DC voltage of offshore MMC is ±100kV, the proportion of FB-SMs must not be less than 34.375% [13].”
BackgroundInfluentialElserougi, A. A., Massoud, A. M., & Ahmed, S. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2788398 · Cited by 8
“In addition, the operation of MMC requires proper control to ensure a successful operation with balanced capacitor voltages, which necessitates the employment of suitable controller.”
BackgroundInfluentialZhu, J., Wei, T., Huo, Q., & Yin, J. (2018) · Energies · doi:10.3390/en12010091 · Cited by 9
Zhou, W., Yang, H., Yang, H., Chen, M., Li, W., He, X., & Han, J. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8721882 · Cited by 8
Interconnection of VSC‐HVDC and LCC‐HVDC using DC–DC autotransformer
Yang, Z., Li, M., Lu, X., Xiang, W., Zuo, W., Yao, L., Lin, W., & Wen, J. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.9270 · Cited by 8
Self-citationWang, C., Tian, C., Cheng, H. L., & Deng, J. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3161665 · Cited by 8
“It is widely applied in medium- and high-voltage power electronic transformers [6], novel transformerless cascaded medium- and high-voltage converters [7], static var generators [8]–[10], and modular multilevel converters [11], [12].”
BackgroundFault Diagnosis in Five-level CHB Inverter using Normalization Factor and THD Analysis
Mehta, P., Kumar, M., & Sahoo, S. (2018) · IEEE India International Conference on Power Electronics · doi:10.1109/iicpe.2018.8709547 · Cited by 10
“There are few more topologies which is derived from above mentioned basic structures of ML inverter such as active neutral point clamped (ANPC) [6], [7], T-type ML inverter [8], modular multilevel converter (MMC) [3], [9].”
BackgroundModeling of MMCs With Controlled DC-Side Fault-Blocking Capability for DC Protection Studies
Leterme, W., Judge, P. D., Wylie, J., & Green, T. C. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2954743 · Cited by 11
“This voltage must be at least equal to the amplitude of the ac system’s phase voltage υac in a star-connected configuration or half the amplitude of the ac systems’ line-to-line voltage in a delta-connected configuration, as detailed in [40].”
BackgroundLu, Y., Huang, Y., Zhao, X., Xu, D., Guo, L., & Qin, K. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8713 · Cited by 7
Hybrid Modular Multilevel Converter with DC Fault Blocking Capability
Das, B., Kumar, A. D., Kasari, P. R., & Chakrabarti, A. (2018) · International Electrical Engineering Congress (iEECON) · doi:10.1109/ieecon.2018.8712213 · Cited by 7
“Basic building blocks of 2:1 HMMC and proposed HMMC are Sub-Modules and switches so the comparison between number of SMs and IGBTs and also about the output voltage produced by the both configuration is shown in Table 3 [2].”
MethodZhou, W., Yang, H., Chen, M., Li, W., He, X., & Han, J. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8722172 · Cited by 8
Dynamic preventive maintenance strategy for MMC considering multi-term thermal cycles
Feng, F., Yu, J., Yang, Z., Dai, W., Zhao, X., Kamel, S. M., Wang, J., & Fu, G. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105560 · Cited by 8
Novel MMC Sub-Module Topology With DC Fault Clearing Capability
Mao, L., Li, Z., & Chen, Y. (2023) · IEEE Access · doi:10.1109/access.2023.3348411 · Cited by 7
“Literature [17], [18], [19] respectively proposed hybrid MMC with different topologies and control strategies.”
BackgroundA new three-level switched-capacitor submodule for modular multilevel converters
Elserougi, A. A., Ahmed, S., & Massoud, A. M. (2016) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2016.7474757 · Cited by 8
“Various types of SMs have been proposed by different researchers such as the half-bridge [5], full-bridge [6], modified full-bridge [7], cross-connected SM [7], clamp double SM [6], asymmetrical SM [8], mixed cells [9, 10], modified mixed cells [11], combined full-bridges SM [12], and fault ride-through switched capac…”
BackgroundRahman, H., Li, R., Yao, L., & Xu, L. (2018) · The Journal of Engineering · doi:10.1049/joe.2018.8610 · Cited by 7
“[13] J. Peralta, H. Saad, S. Dennetiere, J. Mahseredjian, and S. Nguefeu, "Detailed and Averaged Models for a 401-Level MMC HVDC System," IEEE Trans.”
BackgroundSelf-citationModular multilevel converters: A study on topology, control and applications
Kurtoğlu, M., Eroğlu, F., Arslan, A. O., & Vural, A. M. (2018) · doi:10.1109/iceee2.2018.8391305 · Cited by 8
“A new topology named as hybrid MMC consisting of HBSMs and FBSMs is proposed in [31], which is validated by both simulation and experiment.”
Energy-Based Virtual Damping Control of FB-MMCs for HVDC Grid
Zhou, D., Li, R., Xu, L., & Wang, Y. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3040815 · Cited by 7
“hybrid MMCs [22], cross-connected SM based MMCs [23, 24], etc.”
BackgroundSelf-citationModular multilevel converter composite submodule topology and control
Zhang, J., Chang, J., & Han, Y. (2018) · The Journal of Engineering · doi:10.1049/joe.2018.8660 · Cited by 10
Minimization of the Number of Full-Bridge Submodules in Hybrid Modular Multilevel Converter
Bandaru, T., Bhattacharya, T., & Chatterjee, D. (2018) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes.2018.8707845 · Cited by 8
“However, the choice of number of HB-SMs and FB-SMs depends on various factors [4]-[6].”
BackgroundMethodInfluentialLu, M., Han, W., Zhao, Y., & Ma, X. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.109910 · Cited by 9
Development of a Flexible Modular Multilevel Converter Test-Bed
Zhang, S., Wang, S., Praisuwanna, N., Kong, L., Li, Y., Martin, R. B., Wang, F., & Tolbert, L. M. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557403 · Cited by 6
“Recently, a hybrid MMC topology with both half-bridge and full-bridge SMs in one MMC is proposed to block the dc fault current with less switches than the MMC with pure fullbridge SMs [14], [15].”
BackgroundA New Hybrid Submodule for MMC with DC Fault Ride-Through Capability
Rudrasimha, Y. A., Ghat, M. B., & Shukla, A. (2018) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes.2018.8707560 · Cited by 6
The Switched Modular Multilevel Converter: A Compact VSC for High and Medium Voltage Applications
Reddy, G. A., & Shukla, A. (2022) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2022.3144834 · Cited by 7
“In the event of a dc-side short circuit fault, the SMs capacitors start to discharge until the converter is blocked [23].”
BackgroundInfluentialAn Improved Phase-Disposition Pulse Width Modulation Method for Hybrid Modular Multilevel Converter
Zhou, F., Xiang, X., Ma, F., Wang, Y., Zhou, F., & Peng, P. (2023) · Energies · doi:10.3390/en16031192 · Cited by 7
A hybrid arm‐multiplexing MMC for DC fault ride‐through without blocking
Wang, Y., Li, Y., Wang, C., & Tao, J. (2023) · IET Renewable Power Generation · doi:10.1049/rpg2.12724 · Cited by 6
Asymmetric mixed modular multilevel converter topology in bipolar HVDC transmission systems
Jung, J.-J., Lee, J.-H., & Sul, S. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8095985 · Cited by 6
“The problems of the conventional SYM-MMC structure and the validity of ASYM-MMC have been verified by both computer simulation and experimental results in [4-5, 9-11].”
MethodFour-channel control of hybrid MMC with pole-to-ground DC fault ride through capability
Xiang, W., Lin, W., Wen, J., & Luo, C. (2017) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2017.8274677 · Cited by 7
“Reference [2] firstly proposed the hybrid MMC topology.”
BackgroundAn Improved Sub-Module Topology for Protecting MMC Power Devices under DC-side Short Circuit Fault
Huihui, Z., Luo, L., Jia, L., Yang, L., & Yang, S. (2018) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc.2018.8408027 · Cited by 6
“MMC mainly uses HBSM as the basic SM [4-5].”
MethodActive Thermal Control of Hybrid MMC Under Over-Modulation Operation
Sheng, J., Xu, H., Li, W., He, X., Lin, L., Hu, J., & Li, S. (2018) · IEEE International Power Electronics and Application Conference and Exposition (PEAC) · doi:10.1109/peac.2018.8590219 · Cited by 6
“The hybrid MMC using both HBSMs and FBSMs makes a tradeoff between reducing power device quantity and handling DC fault, becoming more competitive in the future over-head line HVDC projects [3].”
BackgroundMethodHybrid Modular Multilevel Converter with Self-Balancing Structure
Zhang, Y., Zhang, J., Xu, Z., Deng, F., & Zhao, J. Q. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9235881 · Cited by 6
“There have been some control approaches to solve the voltage imbalance [9], [16-19].”
BackgroundNew Sub-Module with Reverse Blocking IGBT for DC Fault Ride-Through in MMC-HVDC System
Kim, U.-J., & Oh, S.-G. (2021) · Energies · doi:10.3390/en14061551 · Cited by 6
Efficient modeling of hybrid MMCs for HVDC systems
Zhang, L., Qin, J., Shi, D., & Wang, Z. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8095987 · Cited by 6
Compact mixed cell modular multilevel converter
Adam, G. P., Li, R., Xu, L., & Abdelsalam, I. (2018) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2018.8352254 · Cited by 6
“For an example, a MC-MMC has received significant attention in recent years as it permits customized design of the MMC for control flexibility versus semiconductor losses, while retaining many of the attributes of the MMCs such as modularity and internal fault management [8, 10, 13-16].”
BackgroundSelf-citationPredictive-based Modulation Schemes for the Hybrid Modular Multilevel Converter
Donoso, F., Mora, A., Espinoza, M., Urrutia-Ortiz, M., Espina, E., & Cárdenas, R. (2019) · European Conference on Power Electronics and Applications · doi:10.23919/epe.2019.8914876 · Cited by 6
“In addition, according to the simulation results the capacitor voltage unbalance problem occurs using the MS-I for m 2 while the MS-II is able to balance the capacitor voltages of FBSMs and HBSMs in the same region without changing the power factor of the grid current.”
BackgroundFarias, J. V. M., Camurça, L., Langwasser, M., & Liserre, M. (2022) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg54999.2022.9923137 · Cited by 5
“Thus, for a maximum modulation index, the dc and peak ac phase voltages can be described by [4]:”
BackgroundInfluentialA Three-stage AC side startup strategy for hybrid MMC
Chen, C., Zhou, L., Guan, H., Dong, Q., & Zhang, K. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108920 · Cited by 5
Bandaru, T., Bhattacharya, T., & Chatterjee, D. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3396790 · Cited by 5
“A hybrid MMC topology, also termed mixed cells MMC, has emerged as a compromise [4], [5], [6] with inherent dc fault handling capability.”
BackgroundMethodModified carrier phase-shifted SPWM for a hybrid modular multilevel converter with HBSMs and FBSMs
Wang, C., Meng, J., & Wang, Y. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512445 · Cited by 5
“When operating under Mode 1, the hybrid MMC is in accordance with the HB-MMC in operational principle and control method [5].”
BackgroundMethodInfluentialLow-Harmonic DC Ice-Melting Device Capable of Simultaneous Reactive Power Compensation
Lu, J., Zhu, S., Li, B., Tan, Y., Zhou, X., Huang, Q., Zhu, Y., & Mao, X. (2018) · Energies · doi:10.3390/en11102596 · Cited by 6
An IGCT-based Multi-functional MMC System with Commutation and Switching
Xu, C., Guo, M., Zhao, B., Tang, B., Yu, Z., Zhai, D., & Ren, C. (2020) · European Conference on Power Electronics and Applications · doi:10.23919/epe20ecceeurope43536.2020.9215678 · Cited by 5
“Full-bridge submodule based MMC (FBSM-MMC) [13], hybrid with full-bridge submodules and half-bridge submodules based MMC (Hybrid-MMC) [14]-[15], clamp double half-bridge submodules based MMC (CDSM-MMC) [16]-[18], and cross-connected arm based MMC (ICCM-MMC) [19] are solutions for DC faults.”
MethodDistributed consensus-based secondary control of multi-terminal DC railway systems
Olives-Camps, J. C., Mauricio, J. M., Maza‐Ortega, J. M., & Gómez‐Expósito, A. (2023) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.108986 · Cited by 5
Reduced Switching Frequency (RSF) Voltage Balancing Technique for 21-Level Hybrid MMC
Bonde, A. D., Chaturvedi, P., Borghate, V. B., & Patro, S. K. (2022) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes56012.2022.10080223 · Cited by 6
“Another approach which provides the boosted output voltage requires modified balancing technique considering the negative level generation of FB-SMs in Hybrid MMC [16].”
BackgroundSeries-Stacked Hybrid Modular Converter with DC Fault Blocking Capability for HVDC Application
Ghat, M. B., & Shukla, A. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557907 · Cited by 5
“This energy storage is same as that required in the conventional MMC [11].”
BackgroundMethodHybrid Double Direction Blocking Sub-Module for MMC-HVDC Design and Control
Zhang, J., Cui, D., Tian, X., & Zhao, C. (2019) · Journal of Power Electronics · doi:10.6113/jpe.2019.19.6.1486 · Cited by 7
Novel Enhanced Modular Multilevel Converter for High-Voltage Direct Current Transmission Systems
Vozikis, D., Alsokhiry, F., Adam, G. P., & Al‐Turki, Y. A. (2020) · Energies · doi:10.3390/en13092257 · Cited by 6
Wang, K., Song, Q., & Xu, S. (2022) · Energies · doi:10.3390/en15031225 · Cited by 6
Sharifabadi, K., Harnefors, L., Nee, H., Norrga, S., & Teodorescu, R. (2016) · Wiley eBooks · doi:10.1002/9781118851555.ch2 · Cited by 8
Sharifi, S., Bieber, L. M., Wang, L., & Jatskevich, J. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3418431 · Cited by 4
“To overcome these challenges, a mixed-bridge submodule (MBSM) MMC, employing an even mixture of HBSMs and FBSMs in each arm, was introduced in [14].”
Fang, X., Li, G., Wang, C., & Li, L. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3317263 · Cited by 5
“In the conventional SM blocking method, all SMs are controlled to block (turn off all IGBTs) simultaneously once a dc fault is detected [1], [9], [12].”
MethodThree-Level Submodules Based Modular Multilevel HVDC Converters With DC Fault Blocking Capability
Geng, Z., Yang, Y. B., Xiao, Y., Xie, W., & Zhou, G. (2024) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2024.3404919 · Cited by 4
“The SMs of Type II mainly include the clamp double SM (CDSM) [12], the switched capacitor SM (SCSM) [13], the mixed connection SM (MCSM) [14] and the asymmetrical double SM (ADSM) [15].”
BackgroundModulation Scheme for Minimizing the Difference in Device-Level Current Stress in FBSM-MMC
Rao, N. P., & Shukla, A. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3411114 · Cited by 4
“Under such conditions, the converter can be designed to operate at a maximum value of modulation index ( m ) greater than unity, without over-modulating it beyond m > 1 [3], [4].”
BackgroundA design method of hybrid modular multilevel converter with negative output generated by FBSM
Lin, Y., Lin, L., Xu, C., & Hu, J. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216769 · Cited by 5
“An applicable capacitor voltage balancing method is introduced in [12], however the switching loss may be increased since both negative and positive output may be generated at one moment.”
BackgroundMethodInfluentialHu, W., Dong, Y., Li, G., Li, W., & He, X. (2018) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2018.8460058 · Cited by 4
“Due to the negative output voltage of FBSMs, the AC voltage of hybrid MMC can be larger than half of the DC voltage [4].”
BackgroundModular multilevel converter based on arm transfer to clear dc fault
Wang, Z., Liu, J., Xiao, Z., Wang, C., & Li, G. (2019) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2018.6311 · Cited by 4
Cost-effective Design of Modular Multilevel Converter Employing Full-bridge Submodules
Yin, J., Leon, J. I., Franquelo, L. G., Vázquez, S., & Marquez, A. (2019) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe.2019.8862324 · Cited by 5
“Since compared with the HB topology, the FB topology requires twice the number of IGBTs, a hybrid design employing both HBSMs and FBSMs is studied in [10], [11] to achieve a trade-off between the amount of IGBTs and the performance of the MMC system.”
BackgroundMethodFang, X., Hu, Z., Gao, C., Xiong, J., & Zhang, K. (2021) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia49820.2021.9479442 · Cited by 4
“Among these topologies, the hybrid MMC is widely recognized as a good choice [3].”
BackgroundColmenero, M., Blánquez, F. R., & Blasco-Giménez, R. (2023) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2023.3336981 · Cited by 4
“The hybrid MMC topology has the ability to adjust its dc voltage within a specific range while maintaining high ac voltage [33].”
BackgroundLi, H., Wang, Q., Wu, Q., Xiao, L., & Li, J. (2024) · Journal of Power Electronics · doi:10.1007/s43236-023-00752-7 · Cited by 5
“For the hybrid MMC in [12], a modified sorting and selection algorithm was presented to balance the capacitor voltage.”
InfluentialAn Optimized Fault-Ride-Through Control Strategy of Hybrid MMC with Fewer FBSMs
Chen, Y., Ren, C., Sheng, J., Wang, J., Zhou, Y., Cao, W., Ding, R., & Wang, W. (2024) · Electronics · doi:10.3390/electronics13101797 · Cited by 4
“To ensure good fault-ride-through capability and safety, the matching of full-bridge submodules should not be too low [19,20].”
BackgroundModeling DC circuit breaker in MTDC for wind farms based on delay slope method
Su, X., Fu, S., Hao, J., Kang, X., Yu, Z., & Yang, R. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793325 · Cited by 4
“In order to minimize disturbance on converter operation, it is necessary to clear the fault with a few milliseconds and restore quickly power after fault clear[1].”
BackgroundA medium-voltage motor drive based on diode-clamped modular multilevel converters
Zheng, T., Gao, C., Liao, X., Liu, X., Sun, B., & Lv, J. (2017) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2017.8056056 · Cited by 7
“Compared to the two-level voltage source converter, MMC have many attracting features such as the modularity of structure, the reduction of converter losses, and high quality of the output waveforms [1], [2], [3], [4].”
BackgroundAdam, G. P., Alsokhiry, F., Abdelsalam, I., Ahmed, K. H., & Al‐Turki, Y. A. (2018) · Electric Power Systems Research · doi:10.1016/j.epsr.2018.06.001 · Cited by 4
Research of control strategies of MMC based on full bridge sub‐modules
Zhang, J., Jiang, C., & Chen, C. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8662 · Cited by 4
Interoperability of different voltage source converter topologies in HVDC grids
Guo, D., Rahman, H., Adam, G. P., Xu, L., Emhemed, A. S., Burt, G., & Audichya, Y. (2019) · IET International Conference on AC and DC Power Transmission (ACDC) · doi:10.1049/cp.2019.0039 · Cited by 4
“Equally, the control of MMC and hybrid converters is extensively investigated in the last decade [14-22].”
BackgroundSelf-citationAn improved submodule unified pulse modulation scheme for a hybrid modular multilevel converter
Lu, S., Li, K., Deng, X., Li, S., & Zhao, Z. (2017) · CES Transactions on Electrical Machines and Systems · doi:10.23919/tems.2017.8086112 · Cited by 4
DC Fault Tolerant Hybrid Multilevel Converter Topologies for High Power Applications
Ghat, M. B., Reddy, A., & Shukla, A. (2018) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes.2018.8707628 · Cited by 5
“Table I summarizes the comparison and applications of major HVDC converter topologies, such as MMC with HBSMs [1]–[4], MMC with all FBSMs [16], hybrid MMC (50%HBSMs and 50%FBSMs) [17], HMMC [8]-[9], AAMMC [10]-[11], MCDHB [12], HMCFB [13]-[14], seriesHBHMC [15], and parallel-HBHMC [15].”
BackgroundAmorim, W. C. S., Mendonça, D. D. C., de Sousa, R. O., Cupertino, A. F., & Pereira, H. A. (2019) · Journal of Control Automation and Electrical Systems · doi:10.1007/s40313-019-00542-2 · Cited by 4
Chang, X., Li, M., Dong, N., Yang, H., & Zhao, R. (2024) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2024.3425731 · Cited by 3
“Compared with conventional FB-MMC with the same capability, HMMC requires fewer power devices [4].”
BackgroundMethodLv, W., Zheng, T., Liu, X., & Judge, P. D. (2024) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2024.3485910 · Cited by 5
“The number of FBSMs is matched to [29], with 2/3 of submodules FBSMs and 1/3 being half-bridge submodules.”
Multilevel converter for X-ray generators
Pernia, A. M., Vaquero, O. P., Villegas, P., Nuño, F., Mayor, H. A., & Martín‐Ramos, J. A. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793368 · Cited by 3
“Topology Focusing on X Ray medical applications [7-12], the proposed converter has to work in two situations defined by the technique used, resulting in the following output specifications: Fluoroscopy: Nominal operation 1.”
MethodModeling and analysis of DC voltage dynamics in modular multilevel converter
Wan, M., Hu, J., He, Z., & He, Z. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216780 · Cited by 3
“For DC fault self-cleaning, many other topologies for converter and SM with negative voltage generating capability have been proposed, such as the full-bridge sub-module (FBSM) based MMC [10], the clamp double sub-module (CDSM) based MMC [11], and the hybrid MMC [12-13] with the combination of the FBSMs and HBSMs and…”
BackgroundControl of hybrid modular multilevel converter based HVDC system under DC short circuit faults
Shahu, V., Bandaru, T., Bhattacharya, T., & Chatterjee, D. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216033 · Cited by 3
“The hybrid MMC topology [8]-[9] is an optimum solution to these problems.”
BackgroundRahimian, M. M., Hosseinpour, M., Basu, M., Farrell, M., & Sajedi, S. (2018) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec.2018.8542048 · Cited by 3
“This is because the current has to flow through two power devices in each FBSMs instead of one power device in half bridge sub-modules (HBSM) [6], so the conduction loss significantly increases.”
BackgroundA Reduced-Switching-Frequency Modulation Method for Hybrid MMCs Under Over-Modulation Conditions
Hu, P., Yin, R., Teodorescu, R., Wang, S., & Guerrero, J. M. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8591364 · Cited by 3
“Hence, the threshold smu will be reached all the time during that time, which cannot reduce the switching frequency for overmodulation hybrid MMCs. B. Proposed reduced-switching-frequency method To resolve this issue, an improved sorting and selecting method is proposed as shown in Fig.6, where armi and armN denote th…”
BackgroundMethodInfluentialAbdelsalam, M. O., Marei, M. I., Diab, H. Y., & Tennakoon, S. B. (2018) · Journal of Power Electronics · doi:10.6113/jpe.2018.18.2.558 · Cited by 3
Metadata
- Authors
- Zeng, R., Xu, L., Yao, L., & Williams, B. W.
- Affiliations
- University of Strathclyde (GB)
- China Electric Power Research Institute (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-03
- Volume
- 30
- Issue
- 3
- Pages
- 1137-1146
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2008773359
- Cited by
- 455
- References
- 24
- Citations by year
- 2026: 17 · 2025: 31 · 2024: 28 · 2023: 32 · 2022: 30 · 2021: 43 · 2020: 39 · 2019: 61 · 2018: 66 · 2017: 47 · 2016: 41 · 2015: 18
- FWCI
- 18.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) (acceptedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- hybrid modular multilevel converter, full-bridge submodules, half-bridge submodules, DC fault blocking, capacitor voltage balancing, equivalent circuit model, power losses, device utilization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.