Design and Operation of a Hybrid Modular Multilevel Converter
The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Abstract
This paper presents a hybrid modular multilevel converter (MMC), which combines full-bridge submodules (FBSM) and half-bridge submodules (HBSM). Compared with the FBSM-based MMC, the proposed topology has the same dc fault blocking capability but uses fewer power devices hence has lower power losses. To increase power transmission capability of the proposed hybrid MMC, negative voltage states of the FBSMs are adopted to extend the output voltage range. The optimal ratio of FBSMs and HBSMs, and the number of FBSMs generating a negative voltage state are calculated to ensure successful dc fault blocking and capacitor voltage balancing. Equivalent circuits of each arm consisting of two individual voltage sources are proposed and two-stage selecting and sorting algorithms for ensuring capacitor voltage balancing are developed. Comparative studies for different circuit configurations show excellent performance balance for the proposed hybrid MMC, when considering dc fault blocking capability, power losses, and device utilization. Experimental results during normal operation and dc fault conditions demonstrate feasibility and validity the proposed hybrid MMC.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The blocking of a dc fault in an MMC can be achieved when the total voltage of connected submodules along the fault current path is greater than the line-to-line ac voltage [111].”
From Modular Multilevel Converters: Recent Achievements and Challenges (2021) · cites this paper as [111]
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundTu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Self-citationDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 3×
“Thus, in contrast to the conventional capacitor voltage balancing algorithm [2], in which only capacitor voltage and arm current direction are used for SM selection, the selection of SMs in the hybrid MMC has to consider the differences in their behavior, and charging and discharging periods between the FBSMs and HBSM…”
BackgroundMethodResultModulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934 · cited 2×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundMethodShort-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790 · cited 1×
“However, an HBSM-based MMC (HB-MMC) does not have dc fault blocking capability, thus relies on ac or dc circuit breakers to isolate dc faults [13], [14].”
BackgroundMarquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundIlves, K., Antonopoulos, A., Norrga, S., & Nee, H.-P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159809 · Cited by 578 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundA Steady-State Analysis Method for a Modular Multilevel Converter
Song, Q., Liu, W., Li, X., Rao, H., Xu, S., & Li, L. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227818 · Cited by 503 · cited 2×
“A detailed analysis on the impact of the circulating current on capacitor voltage ripple is provided in [23].”
Background
Research works printed but not linked: 1
- backlund, 2012, Data sheet IGBT module 5SNA 1200G450300
Cited by
Items 301–400 of 455
Hao, L., Liu, C., Zhan, Q., Chen, Z., & Wang, X. (2021) · Energy Reports · doi:10.1016/j.egyr.2021.08.065 · Cited by 3
Zhang, Z., Wang, H., Wang, K., & Zhao, Y. (2021) · IEEE Access · doi:10.1109/access.2022.3190411 · Cited by 3
Bandaru, T., Bhattacharya, T., & Chatterjee, D. (2022) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes56012.2022.10080497 · Cited by 3
“A hybrid MMC topology, also termed as mixed cells MMC, has emerged as a compromise [9]-[14] with inherent dc fault handling capability.”
BackgroundMethodMaximum utilization of DC link voltage in grid connected hybrid modular multilevel converter
Kumar, A. D., Das, B., Kasari, P. R., & Chakrabarti, A. (2017) · doi:10.1109/iciteed.2017.8250465 · Cited by 3
A Fault Ride- Through Strategy Based on MMC Inner Capacitor Energy Storage
Xiao, Y., Li, P., & Chen, P. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8591804 · Cited by 3
“Besides, different degrees of dc voltage sag are also investigated, which is caused by different faults, like lightning strikes, pollution or ac-side fault on the other stations [8, 9].”
BackgroundKhera, F. A., Klumpner, C., & Wheeler, P. W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2955859 · Cited by 3
“It was reported in [14] that the maximum output voltage is restricted to 1.”
BackgroundLu, X., Xiang, W., & Wen, J. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927533 · Cited by 3
“The topology design principle and DC fault ride through schemes for the hybrid MMC are researched in [1]-[5].”
BackgroundControl of power electronics-driven power sources
Qoria, T., & Guillaud, X. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818491-2.00008-0 · Cited by 3
Adam, G. P., Alsokhiry, F., & Alabdulwahab, A. (2021) · Electric Power Systems Research · doi:10.1016/j.epsr.2021.107595 · Cited by 3
A novel MMC sub-module based on controllability theory
Li, X., Zhang, B., Zhang, Z., Qu, L., & Liao, H. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216833 · Cited by 4
“the half bridge sub-module (HBSM) [10], the full bridge sub-module (FBSM) [11] and the clamp double sub-module (CDSM) [12].”
BackgroundInfluentialJiang, X., & Bakran, M. (2018) · Advances in Power Electronics · doi:10.1155/2018/2719380 · Cited by 3
“Because the modified SMs have more losses during normal operation, the hybrid MMC is considered [8].”
BackgroundLow DC voltage control strategy of bipolar LCC-MMC hybrid HVDC transmission system
Cai, Y., Wen, M., Chen, Y., Shi, Y., & Qin, Y. (2017) · International Conference on Power and Renewable Energy (ICPRE) · doi:10.1109/icpre.2017.8390521 · Cited by 3
“The capability to run at low DC voltage and deal with DC fault of hybrid MMC have been a hot topic [7], [8], [13][15].”
BackgroundOperation and Control Analysis of Modular Multilevel Converter for VSC-HVDC Application
Lin, H., & Wang, Z. (2017) · International Journal of Electronics and Electrical Engineering · doi:10.18178/ijeee.5.3.195-201 · Cited by 3
“in [29] propose a hybrid MMC with both HB-SM and FB-SM in each arm, and the variations for different SMs capacitor selection are deduced based on their interactive behavior.”
BackgroundA Four-Port Single-stage AC-AC Converter for SST Applications
dos Santos, C. A., Mazza, L. C. D. S., Antunes, F. L. M., Oliveira, D. S., & Pracca, P. P. (2018) · IEEE International Conference on Industry Applications · doi:10.1109/induscon.2018.8627282 · Cited by 4
Capacitor Ripple Reduction with Novel Modulation Scheme in Modular Multilevel Converters
Rahmati, S., Veysinejad, A., & Bina, M. T. (2020) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc49159.2020.9088441 · Cited by 3
“The modification has been made in the existing voltage-balancing algorithm in the literature [2] and [3] to select and insert modules negatively according to the signal modulation, which improves the performance of the MMC.”
BackgroundMethodInfluentialContinuous operation of LVDC source/load under DC faults in MMC-DC distribution systems
Li, B., Lv, H. P., Wen, W., Liu, H., Zhang, Z., Li, G., Li, B., & Wang, Y. (2021) · Electric Power Systems Research · doi:10.1016/j.epsr.2021.107065 · Cited by 3
“According to fault current interruption measures proposed by scholars from all over the world, there are two typical system frameworks: half bridge submodules (HBSM) based MMC-DC (HB-MMC-DC) system with direct current circuit breakers (DCCBs) [14]-[18] and full bridge submodules (FBSM) based MMC-DC (FB-MMC-DC) system…”
ResultModular Multilevel Converters: Key Features, Control Strategies and Main Challenges
del Giudice, D., Bizzarri, F., Linaro, D., & Brambilla, A. (2022) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-031-12818-9_2 · Cited by 3
Finite-Set Model Predictive Control for a Hybrid Modular Multilevel Converter in a Microgrid
Hosseinpour, H., Dragičević, T., Benidris, M., & Fajri, P. (2022) · North American Power Symposium (NAPS) · doi:10.1109/naps56150.2022.10012246 · Cited by 3
The design and fault ride through control of un-interrupted DC-DC Autotransformer
Li, M., Xiang, W., Zuo, W., Yao, L., Lin, W., & Wen, J. (2018) · Science China Technological Sciences · doi:10.1007/s11431-017-9312-9 · Cited by 3
Self-citationYin, L., Liu, Y., Wu, Y., Li, Z., Zhou, F., Liu, J., & Zheng, G. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3572034 · Cited by 2
Li, Y., Guo, P., Xu, Q., Guerrero, J. M., & Yue, Y. (2025) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2025.111303 · Cited by 2
Voltage Balancing Control Strategy for Hybrid MMC Based on BADS-Optimized Second Harmonic Injection
Fang, Y., Gu, J., Liu, F., Liu, Y., & Shi, S. (2025) · Energies · doi:10.3390/en18225904 · Cited by 2
Usman, M., Kwon, I., & Lee, B.-W. (2025) · IEEE Access · doi:10.1109/access.2025.3612191 · Cited by 2
“Therefore, to ensure appropriate charging and discharging time for HBSMs, allowing capacitor voltage balancing within each ac cycle, N FB should not exceed N T / 2 while modulation index for such HMMC must be less than or equal to 2 [19].”
Tan, P., Lv, C., Liu, J., Li, Y., Wang, Y., & Qin, J. G. (2025) · IEEE International Power Electronics and Application Symposium (PEAS) · doi:10.1109/peas66638.2025.11403588 · Cited by 2
“Considering both economic cost and DC fault ride-through capability, the hybrid MMC that combines half-bridge and full-bridge submodules demonstrates significant advantages in large-scale power transmission systems [14].”
Power Limitation Analysis of Hybrid MMC Considering Sub-Module Balancing Constraint
Lu, X., Xiang, W., Wen, J., & Lin, W. (2018) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2018.8586595 · Cited by 2
“Some assumptions The sorting and balancing algorithm is essential for successful sub-module balancing from the perspective of control system, which has been researched in [1].”
BackgroundJiang, Y., Shao, Z., & Shu, H. (2022) · International Conference on Smart Power & Internet Energy Systems (SPIES) · doi:10.1109/spies55999.2022.10081962 · Cited by 2
“Under extreme weather conditions, reduced DC voltage operation of HVDC systems can improve the reliability of the power grid with overhead transmission lines [7].”
BackgroundInfluentialA Novel DC Fault Ride-through Coordinated Control Strategy for DC Grid with Hybrid MMC
Jiang, S., Li, G., Wang, X., Xin, Y., Wang, W., & Wang, Y. (2022) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec58067.2023.10166667 · Cited by 2
Shamshuddin, M. A., Kennel, R. M., & Verdugo, D. (2025) · IEEE Access · doi:10.1109/access.2025.3546880 · Cited by 3
“Additionally, the authors in [58], [59], and [60] introduced a hybrid MMC incorporating both the bridge cell and chopper cell, to ensure DC fault ride-through capability, enhanced reliability, and reduced CapEX owing to a lower semiconductor count.”
Fault-Tolerant Operation of Hybrid Modular Multilevel Converter for MVDC Applications
Bonde, A. D., Chaturvedi, P., & Borghate, V. B. (2024) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes61459.2024.10960739 · Cited by 2
“The configuration in [13] is taken into consideration for further analysis.”
A Hybrid MMC-based induction motor drive with no torque restrictions at low speeds
Soto, D., Reyes, L., & Cárdenas, R. (2021) · IEEE International Conference on Automatica · doi:10.1109/icaacca51523.2021.9465190 · Cited by 2
Comprehensive Analysis of the Control Structures for MMC Applications
Isik, S., Alharbi, M., & Bhattacharya, S. (2021) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce47101.2021.9595092 · Cited by 2
Hierarchical voltage balancing method for MMC based on DCSM
Li, D., Ji, Z., Zhao, J., Sun, Y., Wang, S., & Ni, X. (2022) · IET Power Electronics · doi:10.1049/pel2.12328 · Cited by 2
Xiang, W., Lin, W., Yao, L., Wen, J., & Wang, Z. (2016) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2015.1194 · Cited by 2
Self-citationTOV in SMs during MMC riding through zero DC voltage fault: analysis and suppression
Hu, J., Lu, M., & Lin, L. (2016) · The Journal of Engineering · doi:10.1049/joe.2016.0194 · Cited by 2
Controlled transition bridge multilevel converter
Adam, G. P., Ahmed, K. H., Holliday, D., Finney, S. J., Burt, G., & Williams, B. W. (2016) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2016.7884445 · Cited by 2
Self-citationAnalytical model of hybrid MMC for dynamic and steady‐state studies
Lu, X., Xiang, W., Lin, W., & Wen, J. (2017) · The Journal of Engineering · doi:10.1049/joe.2017.0737 · Cited by 2
Simplified direct modulation prediction approach for modular multilevel converter
Huang, J., Sun, Y., Zhang, X., Tong, X., & Gao, S. Q. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216783 · Cited by 2
“Its topology is especially well suited for medium and high voltage applications such as direct current transmission, power electronic transformer, etc.[3], [4].”
BackgroundXu, C., Lin, L., & Hu, K. (2018) · 2018 1st Workshop on Wide Bandgap Power Devices and Applications in Asia (WiPDA Asia) · doi:10.1109/wipdaasia.2018.8734551 · Cited by 2
Circulating Current Control for Hybrid MMCs under DC Voltage Sag
Hu, P., Xiao, Q., Guo, J., Du, Y., & Yin, R. (2019) · IEEE Innovative Smart Grid Technologies-Asia · doi:10.1109/isgt-asia.2019.8881771 · Cited by 2
“[8] proposed to supply some reactive power to the AC grid to provide a sufficient charging or discharging interval for HBSMs, which however will decrease the power factor; [9] proposed to increase FBSM number, which obviously increased the cost and loss.”
BackgroundLu, X., Li, M., Xiao, J., Ye, L., & Pan, X. (2021) · Asia Energy and Electrical Engineering Symposium (AEEES) · doi:10.1109/aeees51875.2021.9402968 · Cited by 2
“By proper designing the submodule ratio and enhancing the current control strategy, the hybrid MMC can actively isolate the DC fault current [2-3].”
BackgroundAn FBSM Capacitor Overvoltage Easing Method by Controlling the Arm Current Commutation of Hybrid MMC
Fang, X., Hu, Z., Xing, Y., Xiong, J., & Zhang, K. (2021) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia49820.2021.9479320 · Cited by 2
Development and Analysis for the Optimal Structure of a Multilevel Voltage Source Inverter
Fedotov, V. V., & ROZHKOV, V. V. (2021) · International Ural Conference on Electrical Power Engineering (UralCon) · doi:10.1109/uralcon52005.2021.9559526 · Cited by 2
Lu, X., Li, M., Lei, X., Yang, Z., Peng, D., & Luo, D. (2021) · Energy Reports · doi:10.1016/j.egyr.2021.08.008 · Cited by 2
Optimal Redundancy Configuration of Hybrid MMC Considering Maintenance Cost of Life Cycle
Zhang, Y., Hao, Q., & Han, X. (2021) · International Conference on Power and Renewable Energy (ICPRE) · doi:10.1109/icpre52634.2021.9635548 · Cited by 2
“1 (20) where crh and crf are the replacement costs of FBSM and HBSM, respectively; cwh and cwf are the maintenance costs of HBSM and FBSM, respectively; and cp represents the loss of planed shutdown.”
BackgroundWu, J.-P., Guo, M., & Gao, W. (2021) · International Conference on Power and Renewable Energy (ICPRE) · doi:10.1109/icpre52634.2021.9635404 · Cited by 2
“In [14], a hybrid MMC with FBSM and HBSM is introduced, and the ratio of FBSM to HBSM is analyzed by considering the relationship between dc and ac voltage.”
MethodHuang, M. D., & Li, J. (2022) · Energies · doi:10.3390/en15072370 · Cited by 3
THD Analysis of Modular Multi-level Converter with BESS
Pyo, S.-H., Lee, S.-J., Shin, D., Kang, D.-W., Lee, J.-P., & Park, T. (2023) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2023-ecceasia54778.2023.10213622 · Cited by 2
“The proposed MMC-BESS is a system consisting of a Single-Delta Bridge Cell (SDBC), which is connected to the grid in parallel through a Y-delta transformer to perform the role of STATCOM and ESS.”
MethodComprehensive Analysis of Capacitor Voltage Ripple for Hybrid MMCs Under Over-Modulation Conditions
Chang, X., Li, M., Dong, N., Yang, H., & Zhao, R. (2023) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2023-ecceasia54778.2023.10213902 · Cited by 2
“INTRODUCTION Recently, Hybrid modular multilevel converter (Hybrid MMC) is receiving increasingly attention due to its inherent superior capabilities, which include the overmodulation operating and dc short-circuit fault ridethrough (DC-FRT) capabilities [1].”
BackgroundInfluentialEnhanced Efficiency of MV Hybrid MMC under Extended Modulation using Si/SiC devices
Shahane, R. T., Rao, N. P., & Shukla, A. (2023) · European Conference on Power Electronics and Applications · doi:10.23919/epe23ecceeurope58414.2023.10264513 · Cited by 2
“The half-bridge submodules (HBSMs) and fullbridge submodule (FBSMs) connected together in an arm constitute a hybrid modular multilevel converter (HMMC) [1].”
BackgroundAlia, I., Merzouk, I., & Osama, A. M. (2023) · International Conference on Decision Aid Sciences and Applications (DASA) · doi:10.1109/dasa59624.2023.10286773 · Cited by 3
Hsieh, Y.-H., & Lee, F. C. (2018) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/epepemc.2018.8521988 · Cited by 2
“capacitors [7][8] and short-circuit protection of the highvoltage DC-BUS [9][10].”
BackgroundA New Cascaded Multi-Level Phase Structure Suitable for High-Voltage High-Power Applications
Liu, W., Sun, S., Liu, Y., Si, R., Mao, Y., Shao, H., & Jia, P. F. (2018) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei2.2018.8582093 · Cited by 2
“Furthermore, literature [22] replaces some HB SMs with FB SMs, featuring the DC fault overriding capability.”
BackgroundHsieh, Y.-H., & Lee, F. C. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8592853 · Cited by 2
A Comprehensive Analysis of Delta and Adaptive Delta Modulated Modular Multilevel Converter
Jaiswal, R., Agarwal, A., & Agarwal, V. (2019) · Lecture notes in electrical engineering · doi:10.1007/978-981-15-0214-9_28 · Cited by 2
Boost Modular Multilevel Converter’s Capacitor Voltage Balancing without voltage sensors
Das, B., Bhattacharya, A., & Chatterjee, D. (2020) · IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE) · doi:10.1109/pesgre45664.2020.9070394 · Cited by 2
“MMCs implemented in literature such are the half-bridge sub-modules (HB-SM) [8], full-bridge sub-modules (FBSM) and clamp double SMs [9], mixed cells [10].”
BackgroundA Hybrid Chain-Link Push-Pull Series Connected (H-CL-P2SC) M2C with DC Fault Blocking Capability
Kaya, M., Costabeber, A., Watson, A. J., Tardelli, F., & Clare, J. (2020) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes49360.2020.9379514 · Cited by 1
“The modulation and capacitor balancing strategy that is described for hybrid CLs in [14] is used in this paper to generate the desired voltages and achieve capacitor balancing in the CLs.”
MethodA Coordinated Start-up Strategy for the DR-MMC-Based Offshore Wind Power Transmission System
Chen, L., Chen, W., Li, Z., Wang, J., Guo, C., Qin, M., Zhang, B., & Du, W. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861253 · Cited by 1
An HVDC System Based on OWT-DMMC With DC Fault Ride-Through Capability
Xin, M., Ma, J., Zhang, Y., Wang, S., Tu, H., Jiao, N., Wang, P., & Liu, T. (2025) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2025.3563686 · Cited by 1
“Other topologies, such as hybrid modular multilevel converters (HMMC) [19] and the alternate arm converter (AAC) [20] can also isolate dc faults.”
A Hybrid Modular Multilevel Converter with DC Fault Blocking Capability
Panuganti, K., & Figarado, S. (2025) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias62731.2025.11061586 · Cited by 1
“The control of the proposed HMMC is achieved with ease, while the control of the hybrid MMCs in [14] - [15] proves to be challenging, especially during under-voltage and over-modulation regions as discussed in introduction.”
Zhang, F., Zhang, Y., Liu, Y., Wang, L., & Li, W. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3603515 · Cited by 1
“As a trade-off, the MMC converter composed of hybrid HBSMs and FBSMs for dc-ac application is discussed in [26], [27], [28], [29].”
Alfares, A. (2025) · Energies · doi:10.3390/en18205424 · Cited by 4
A hybrid power source and its control strategy optimization for low-speed electric vehicle
Yan, C., Zhang, J., Shang, X., & Ren, G. (2025) · Proceedings of the Institution of Mechanical Engineers Part D Journal of Automobile Engineering · doi:10.1177/09544070251389156 · Cited by 1
“…voltage output technology, the voltage conversion ratio (about 2–3) of bi-directional DC-DC power converter (BDPC) is optimized to decompose large variable ratios into smaller increments, 49,50 enhance overall efficiency (verified by actual testing 51 ), and enable voltage-speed dynamic matching.”
Luo, Y., Xu, L., Yang, H., Xiang, X., Li, W., & He, X. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3656589 · Cited by 1
“Restrictions apply. voltage manipulation, making it a promising solution for HVDC transmission [6], [7].”
Self-citationChina’s HVDC development for large-scale renewable integration: A system-level technology roadmap
Wei, X., & Jiang, T. (2026) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2026.111932 · Cited by 1
Wang, J., Ren, J., Wang, H., Song, Z., & Tu, X. (2026) · IEEE Access · doi:10.1109/access.2026.3736607 · Cited by 1
“In MMC-UHVDC systems, hybrid modular multilevel converters (HMMC) composed of half-bridge submodules (HBSM) and full-bridge submodules (FBSM) are commonly adopted to achieve DC fault ride-through capability [20], [21].”
Hybrid modular multilevel converter with reduced three-level cells in HVDC transmission system
Li, R., Wu, J. L., Yao, L., Li, Y., & Williams, B. W. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512372 · Cited by 2
“Conventionally, the modulation index m and the per unit voltage increase of TL cell r are set at 1 and 0 respectively, according to the design approach in [4].”
MethodSelf-citationAnalysis of VSC-HVDC System Stability with Protective Reactors
Li, H., Liang, J., Xiong, M., & Zhang, L. (2016) · International Journal of Electronics and Electrical Engineering · doi:10.18178/ijeee.4.5.408-411 · Cited by 1
“Development of Modular Multilevel Converter (MMC) has made VSC-HVDC more competitive in large power transmission due to its advantages of modular design, low switching frequency, high efficiency, and excellent output voltage waveforms [2].”
BackgroundDC–DC autotransformer with un‐interrupted operating capability during DC fault
Li, M., Xiang, W., Zuo, W., Yao, L., Lin, W., & Wen, J. (2017) · The Journal of Engineering · doi:10.1049/joe.2017.0535 · Cited by 1
Self-citationXia, B., Gou, Y., Shi, S., Yang, D., Wang, F., & Zhuo, F. (2022) · International Conference on Smart Power & Internet Energy Systems (SPIES) · doi:10.1109/spies55999.2022.10081997 · Cited by 1
Collins, C. T., Clemow, P., & Green, T. C. (2023) · IET conference proceedings. · doi:10.1049/icp.2023.1317 · Cited by 1
Ji, Y., Guo, P., & Liu, Q. (2024) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.13216 · Cited by 2
A Novel DC Fault Clearing Strategy for HVDC based on Hybrid MMC
Jiao, J., Chen, C., Li, M., & Zhang, K. (2024) · Power System and Green Energy Conference (PSGEC) · doi:10.1109/psgec62376.2024.10721063 · Cited by 1
“In order to obtain the ability for clearing the DC fault current, the proportion of the FBSMs in the arm must be larger than 43.3% [6].”
BackgroundInfluentialLi, Y., Guo, P., Xu, Q., & Guerrero, J. M. (2025) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2025.110729 · Cited by 2
Wu, H. C., Wang, Y., Liu, Y., Zhang, T., Li, R., & Liu, Y. (2025) · Asia Energy and Electrical Engineering Symposium (AEEES) · doi:10.1109/aeees64634.2025.11018953 · Cited by 1
“In the context of the existing solutions, a hybrid MMC (HMMC) is proposed in [7], which is capable of riding through DC short-circuit faults cost-effectively [8].”
Oliveira, R., & Yazdani, A. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557918 · Cited by 1
“To reduce the number of switches in series with the arm current path, and to ensure dc-side fault handling capability, references [16] and [17] have proposed two new MMC topologies: In [16], a configuration based on the FBSM and referred to as the Alternate Arm Converter (AAC) has been proposed, in which each arm is c…”
MethodThe HVDC Dual Transmission System Under DC Short-Circuit Faults
Santos, N. M. R., Pires, V. F., & Silva, J. F. (2019) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2019.8781451 · Cited by 1
“This topology is also characterized by a dual DC-link.”
BackgroundInfluentialModular Multilevel Dc-Dc Converters: A Review
Roy, S. (2019) · i-manager’s Journal on Electrical Engineering · doi:10.26634/jee.13.1.16344 · Cited by 1
A Novel Three-level Submodule for Modular Multilevel Converter with DC Fault Blocking Capability
Hou, W., Zhang, Z., He, R., & Huang, S. (2019) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2019.8921500 · Cited by 1
“Compared with submodules with dc fault capability described in [16-23], the 3LSMs possess faster speed, and the diodes need not to endure reverse voltage or tackle equalizing voltage of several ones.”
BackgroundInfluentialA New Control Strategy for Capacitor Voltage Balance of Hybrid Modular Multilevel Converter
Li, X., Kang, X., Yuan, Y., & Zheng, M. (2019) · IEEE International Conference on Advanced Power System Automation and Protection (APAP) · doi:10.1109/apap47170.2019.9225097 · Cited by 1
“Hybrid MMC topology is a wisely used topology in flexible direct current transmission [4], since it has lower operational loss, lower cost, which has N half bridge submodules (HBSMs) and F full bridge submodules (FBSMs) in each arm.”
BackgroundPartially Signed Binary Voltage Control of Hybrid Modular Multilevel Converter
Lee, H.-W., Lee, S. H., & Park, J.-W. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3041492 · Cited by 1
Direct Capacitor Voltage Control Method of Hybrid MMC during DC Short Circuit Fault
Peng, M., Liu, H., Zhao, X., Xu, J., & Yuan, J. (2020) · International Conference on HVDC (HVDC) · doi:10.1109/hvdc50696.2020.9292882 · Cited by 1
Research on a Novel AC Side Start-up Strategy for Hybrid Modular Multilevel Converter
Chen, C., Guan, H., Lin, S., Xiong, J., & Zhang, K. (2020) · IEEE China International Youth Conference on Electrical Engineering (CIYCEE) · doi:10.1109/ciycee49808.2020.9332695 · Cited by 1
An Optimization Method for Reducing the Sub-module Capacitor Voltage Ripple Amplitude of Hybrid MMC
Yang, Z., Li, X. S., Jiang, W., & Bu, H. (2022) · International Forum on Electrical Engineering and Automation (IFEEA) · doi:10.1109/ifeea57288.2022.10037581 · Cited by 1
“Reference [12] compares hybrid MMC with HBSM MMC and FBSM MMC.”
BackgroundMethodA Comparative Analysis of Modulated Multilevel Converter at Variable Arm Inductance
Jaiswal, R., Agarwal, A., Negi, R., & Agarwal, K. (2022) · IEEE Power India International Conference · doi:10.1109/piicon56320.2022.10045303 · Cited by 1
Control and modulation of modular multilevel converters
Picas, R. (2016) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-106490 · Cited by 1
Xu, J., Zhao, C., Xu, Y. Q., & Zhao, P. (2016) · Electric Power Components and Systems · doi:10.1080/15325008.2016.1198438
“obvious technical advantages compared with the hybrid MMC with different sub-module (SM) topologies [14, 15]:”
BackgroundModulation of Modular Multilevel Converters for HVDC Transmission
Hassanpoor, A. (2016) · DiVA (Digitala Vetenskapliga Arkivet) · Cited by 2
An improved multi-level converter with a novel sub-module circuit
Li, X., Qu, L., Zhang, B., Liao, H., & Zhang, Z. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216839
“The FBSM is more feasibility for dc line fault clearance [7], but it need more semiconductors to generate the desired number of voltage levels compared with HBSM [8],[9].”
BackgroundInfluentialInvestigation of Traditional and Hybrid Modular Multilevel Converters under Various Voltage Levels
Kurtoğlu, M., Arslan, A. O., Eroğlu, F., & Vural, A. M. (2018) · International Symposium on Multidisciplinary Studies and Innovative Technologies (ISMSIT) · doi:10.1109/ismsit.2018.8567314
Research on DC Fault Ride Through of Medium-Low Voltage DC Distribution Network Based on Hybrid MMC
Xu, J., Jia, L., & Xia, J. (2018) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2018.8602174
“During normal operation, the CSSM can operate as HBSM by keeping 3 T on always [10] which can reduce switching losses but increase conduction losses [9], thus the control strategy of hybrid MMC is similar to the half-bridge MMC.”
MethodNew VSC-HVDC Solution with Overhead Transmission Line for BC-SIN Project
Zhu, Z., Liu, Y., Yuan, Z., Zhou, Y., Cao, W., Xu, D., & Xu, S. (2018) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2018.8602065
“For the characteristics of the overhead line of the project, considering the DC fau lt clearing capability, it is recommended to adopt a hybrid modular multilevel converter topology in the project [8]–[11], that is, each bridge arm is configured with a certain proportion of half bridge modules and full bridge modules.”
MethodAnalysis of the AC Side of Modular Multilevel Converters Under Asymmetric Arm Impedance Conditions
Wu, X., Zheng, W., Qi, P., Zhou, T., & Nie, J. (2019) · Lecture notes in electrical engineering · doi:10.1007/978-981-13-9779-0_45
Transient Voltage of Hybrid DCCB for MVDC Distribution grids and Its Mitigation
Cao, H., Zexin, Z., Xiaodong, Z., Dingxiang, D., Xingguo, W., Wen, W., & Ma, J. (2019) · IEEE Innovative Smart Grid Technologies-Asia · doi:10.1109/isgt-asia.2019.8881121
“(3) the method based on direct current circuit breakers (DCCBs) When DCCBs are installed in MVDC distribution system, without blocking MMCs based on half bridge SMs, the fault current could be eliminated within several milliseconds.”
BackgroundInfluentialAnalysis of Fault Blocking Ability of a MMC Improved Double Half Bridge Sub-module
Meng, M., Su, Y., & Luo, Y. (2019) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope.2019.8905514
“5 switch tubes, and its control is more complicated; In reference [9], the hybrid cascade of HBSM and FBSM is applied to the MMC system, which makes the MMC have the ability of fault blocking and reduces the number of switches.”
BackgroundMethodLi, B., Zhao, J., Li, D., Zhang, S., & Jin, C. (2019) · IEEE International Future Energy Electronics Conference (IFEEC) · doi:10.1109/ifeec47410.2019.9014925
“Furthermore, the IGBTs of the HMMC can be kept unblocked when a comprehensive DC short-circuit FRT strategy is employed [10].”
BackgroundMethodInfluentialDaoud, M., Elserougi, A. A., Massoud, A. M., Bojoi, R. I., Abdel-Khalik, A. S., & Ahmed, S. (2019) · Qatar University QSpace (Qatar University) · doi:10.6113/jpe.2019.19.3.714 · Cited by 2
“In a boost MMC, an ac output of kVdc peak, where k is a positive integer and Vdc is the input dc-link voltage, can be generated [15].”
BackgroundMethodDC Fault Transient Characteristics and Fault Ride-through Control Strategy Based on Hybrid MMC-HVDC
Gao, L., Ning, L., Teng, H., Liu, N., & Yin, Y. (2019) · IEEE International Conference on Advanced Power System Automation and Protection (APAP) · doi:10.1109/apap47170.2019.9224830
“Disadvantages of DC fault clearance strategy for blocked converters: Due to the blocking of MMC after DC short circuit fault, the unbalance of capacitor voltage will occur in the submodule during the blocking period, which makes the restart of converter complicated; The unbalance of capacitor voltage will also occur a…”
BackgroundDC Fault Ride-Through Strategy Based on Overmodulation
Cui, M. T., Li, K., Liu, Z., & Li, L. Z. (2021) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/701/1/012075
Babu, V. H., & Balaji, K. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/925/1/012016
Metadata
- Authors
- Zeng, R., Xu, L., Yao, L., & Williams, B. W.
- Affiliations
- University of Strathclyde (GB)
- China Electric Power Research Institute (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-03
- Volume
- 30
- Issue
- 3
- Pages
- 1137-1146
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2008773359
- Cited by
- 455
- References
- 24
- Citations by year
- 2026: 17 · 2025: 31 · 2024: 28 · 2023: 32 · 2022: 30 · 2021: 43 · 2020: 39 · 2019: 61 · 2018: 66 · 2017: 47 · 2016: 41 · 2015: 18
- FWCI
- 18.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) (acceptedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- hybrid modular multilevel converter, full-bridge submodules, half-bridge submodules, DC fault blocking, capacitor voltage balancing, equivalent circuit model, power losses, device utilization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.