Abstract
This paper presents a hybrid modular multilevel converter (MMC), which combines full-bridge submodules (FBSM) and half-bridge submodules (HBSM). Compared with the FBSM-based MMC, the proposed topology has the same dc fault blocking capability but uses fewer power devices hence has lower power losses. To increase power transmission capability of the proposed hybrid MMC, negative voltage states of the FBSMs are adopted to extend the output voltage range. The optimal ratio of FBSMs and HBSMs, and the number of FBSMs generating a negative voltage state are calculated to ensure successful dc fault blocking and capacitor voltage balancing. Equivalent circuits of each arm consisting of two individual voltage sources are proposed and two-stage selecting and sorting algorithms for ensuring capacitor voltage balancing are developed. Comparative studies for different circuit configurations show excellent performance balance for the proposed hybrid MMC, when considering dc fault blocking capability, power losses, and device utilization. Experimental results during normal operation and dc fault conditions demonstrate feasibility and validity the proposed hybrid MMC.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The blocking of a dc fault in an MMC can be achieved when the total voltage of connected submodules along the fault current path is greater than the line-to-line ac voltage [111].”
From Modular Multilevel Converters: Recent Achievements and Challenges (2021) · cites this paper as [111]
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundTu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Self-citationDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 3×
“Thus, in contrast to the conventional capacitor voltage balancing algorithm [2], in which only capacitor voltage and arm current direction are used for SM selection, the selection of SMs in the hybrid MMC has to consider the differences in their behavior, and charging and discharging periods between the FBSMs and HBSM…”
BackgroundMethodResultModulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934 · cited 2×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundMethodShort-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790 · cited 1×
“However, an HBSM-based MMC (HB-MMC) does not have dc fault blocking capability, thus relies on ac or dc circuit breakers to isolate dc faults [13], [14].”
BackgroundMarquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundIlves, K., Antonopoulos, A., Norrga, S., & Nee, H.-P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159809 · Cited by 578 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundA Steady-State Analysis Method for a Modular Multilevel Converter
Song, Q., Liu, W., Li, X., Rao, H., Xu, S., & Li, L. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227818 · Cited by 503 · cited 2×
“A detailed analysis on the impact of the circulating current on capacitor voltage ripple is provided in [23].”
Background
Research works printed but not linked: 1
- backlund, 2012, Data sheet IGBT module 5SNA 1200G450300
Cited by
Li, R., Xu, L., & Yao, L. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2590501 · Cited by 350
“FOR a large multiterminal HVDC system, in the event of a dc fault, it is desirable that the converters connected to the healthy dc lines continue operating without disruption while the faulty branches are quickly isolated [1]–[3].”
BackgroundSelf-citationModular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“current path is greater than the line-to-line ac voltage [111].”
BackgroundFull-Bridge MMC Converter Optimal Design to HVDC Operational Requirements
Lin, W., Jovcic, D., Nguefeu, S., & Saad, H. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2475130 · Cited by 224
“Such topology is named mixed cells MMC in [19] or hybrid MMC in [20]-[21].”
BackgroundCui, S., & Sul, S.-K. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2513426 · Cited by 210
Precharging and DC Fault Ride-Through of Hybrid MMC-Based HVDC Systems
Zeng, R., Xu, L., Yao, L., & Morrow, D. J. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2360042 · Cited by 180
“The basic operation of this MMC configuration, including capacitor voltage balancing, has been analyzed in [17], so this paper will focus on the precharging process of the hybrid MMC and its ride-through capability under a transient dc fault, both of which are vital to the operation of the converter.”
BackgroundMethodSelf-citationReliability Analysis and Redundancy Configuration of MMC With Hybrid Submodule Topologies
Xu, J., Zhao, P., & Zhao, C. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2444877 · Cited by 179
“Therefore, the hybrid MMCs with different SM topologies are emerging as shown in [17]–[19], and normally the HBSM is selected as the fundamental SM topology to support the dclink voltage and the other SMs with higher DFRTI values are responsible for cutting off the dc fault currents.”
Nguyen, T. H., Hosani, K. A., Moursi, M. S. E., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2862247 · Cited by 173
“2(d), which utilizes a combination of HBSM and FBSM connected in series [13], [42], [43].”
MethodContinuous Operation of Radial Multiterminal HVDC Systems Under DC Fault
Li, R., Xu, L., Holliday, D., Page, F., Finney, S. J., & Williams, B. W. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2471089 · Cited by 171
Self-citationAdam, G. P., & Davidson, I. E. A. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2394387 · Cited by 169
“footprint [5], [35].”
Huang, J., Yang, B., Guo, F., Wang, Z., Tong, X., Zhang, A., & Xiao, J. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2774725 · Cited by 152
“series, generating numerous voltage levels [1], [2].”
Efficiency Assessment of Modular Multilevel Converters for Battery Electric Vehicles
Quraan, M., Tricoli, P., D Arco, S., & Piegari, L. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2557579 · Cited by 148
“The modulation index m in the hypothesis of balanced cells is defined as [12], [13]”
BackgroundA New Hybrid Modular Multilevel Converter for Grid Connection of Large Wind Turbines
Debnath, S., & Saeedifard, M. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2266280 · Cited by 147
Merlin, M. M. C., Soto-Sanchez, D., Judge, P. D., Chaffey, G., Clemow, P., Green, T. C., Trainer, D. R., & Dyke, K. J. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2723948 · Cited by 142
“Here, the H-MMC is taken to have the same number of SMs as the HB-MMC but with half of them replaced by full-bridge SMs [16].”
MethodResultWang, J., Ma, H., & Bai, Z. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2679439 · Cited by 140
Reliable Modular Multilevel Converter Fault Detection With Redundant Voltage Sensor
Picas, R., Zaragoza, J., Pou, J., & Ceballos, S. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2526684 · Cited by 134
“Multiple studies analyze their reliability and provide solutions to faults on the dc side [16]–[18] and ac side [19] of the converter.”
BackgroundA New Topology of Multilevel VSC Converter for a Hybrid HVDC Transmission System
Jung, J.-J., Cui, S., Lee, J.-H., & Sul, S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2598368 · Cited by 135
“Voltage ripple and capacitance of the submodule cells are a significant factor for MMC systems [25].”
BackgroundHybrid HVDC for Integrating Wind Farms With Special Consideration on Commutation Failure
Zeng, R., Xu, L., Yao, L., Finney, S. J., & Wang, Y. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2440354 · Cited by 123
Self-citationAnalysis and Enhanced Control of Hybrid-MMC-Based HVDC Systems During Asymmetrical DC Voltage Faults
Hu, J., Xu, K., Lin, L., & Zeng, R. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2568240 · Cited by 119
“However, to the best knowledge of the authors, few papers concentrate on the protection of PTG fault for the HVDC system based on hybrid MMC [19], [20], even though it happens more commonly and frequently compared to the dc side PTP fault [21].”
BackgroundSelf-citationA Hybrid Modular Multilevel Converter With Novel Three-Level Cells for DC Fault Blocking Capability
Li, R., Fletcher, J. E., Xu, L., Holliday, D., & Williams, B. W. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2423258 · Cited by 115
“In [29], a mixed HB and FB configuration was pro-”
BackgroundSelf-citationRecent Advancements in Submodule Topologies and Applications of MMC
Ali, S., Ling, Z., Tian, K., & Huang, Z. M. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2990689 · Cited by 119
Enhanced Independent Pole Control of Hybrid MMC-HVdc System
Xiang, W., Lin, W., Xu, L., & Wen, J. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2715040 · Cited by 112
“The design, operation and improved PWM modulation of hybrid MMC have been discussed in [8]–[10].”
BackgroundSelf-citationCoordinated Control of Parallel DR-HVDC and MMC-HVDC Systems for Offshore Wind Energy Transmission
Li, R., Yu, L., Xu, L., & Adam, G. P. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931197 · Cited by 111
“The half-bridge (HB) submodule (SM)-based MMCs are adopted for the offshore and onshore MMC stations [17].”
MethodSelf-citationEfficient Modeling of an MMC-Based Multiterminal DC System Employing Hybrid HVDC Breakers
Ahmed, N., Ängquist, L., Mahmood, S., Antonopoulos, A., Harnefors, L., Norrga, S., & Nee, H. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2398825 · Cited by 120
“However, in case of a dc-side fault, this topology continues to feed a fault current from the ac side even if the converter is blocked [14].”
BackgroundChen, Q., Li, R., & Cai, X. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2623672 · Cited by 109
“Because of much simpler control and modulation [18], [19], an HMMC with half-bridge and full-bridge is chosen in this paper to handle the dc grid fault.”
BackgroundMethodZhao, C., Li, Y., Li, Z., Wang, P., Ma, X., & Luo, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2660532 · Cited by 96
“Its design and operation principles with utilizing the negative voltage state of FBSMs were presented in [23].”
BackgroundDC Fault Current Clearance at the Source Side of HVDC Grid Using Hybrid MMC
Xu, J., Zhao, X., Jing, H., Liang, J., & Zhao, C. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2927234 · Cited by 95
“The simplest way to decrease the DC voltage is blocking the converters with DC fault clamping capabilities such as full-bridge MMC [18].”
BackgroundOperating DC Circuit Breakers With MMC
Cwikowski, O., Wood, A. R., Miller, A., Barnes, M., & Shuttleworth, R. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2658540 · Cited by 92
“Several FBC architectures have been proposed, along with associated novel control schemes [7-10].”
BackgroundJudge, P. D., & Green, T. C. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2874209 · Cited by 96
“[25] or Alternate Arm Converter [26], then the negative voltage of the standard SMs could be used to partially compensate for”
MethodLu, M., Hu, J., Zeng, R., Li, W., & Lin, L. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2743780 · Cited by 92
“In [10], reactive power was used to generate a sufficient charging or discharging interval for the HBSMs, but decreased the power factor.”
BackgroundMethodSelf-citationNew Efficient Submodule for a Modular Multilevel Converter in Multiterminal HVDC Networks
Adam, G. P., Abdelsalam, I., Fletcher, J. E., Burt, G. M., Holliday, D., & Finney, S. J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2603180 · Cited by 84
“An improved version of the method is discussed in [7], [13], and [18]–[20], which includes two additional cascaded control loops that regulate the average cell capacitor voltage per phase leg and common-mode current [21]–[23].”
BackgroundMethodOffshore AC Fault Protection of Diode Rectifier Unit-Based HVdc System for Wind Energy Transmission
Li, R., Yu, L., & Xu, L. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2869357 · Cited by 81
“The hybrid MMC with mixed half-bridge and full-bridge submodules in each arm is adopted for the onshore station [18], which regulates the dc voltage and allows reduced dc voltage operation of the DRU-HVdc link in the event of disconnecting one DRU, which will be demonstrated in Section V.”
MethodSelf-citationReview on DC transmission systems for integrating large‐scale offshore wind farms
Li, Z., Song, Q., An, F., Zhao, B., Yu, Z., & Zeng, R. (2021) · Energy Conversion and Economics · doi:10.1049/enc2.12023 · Cited by 83
“The hybrid MMC containing hybrid HB-FB-SMs maintains the DC fault blocking capability, but the hybrid MMC needs fewer IGBTs than FB-MMC and has a more complex control strategy [13].”
BackgroundSelf-citationLow-Energy Protection System for DC Grids Based on Full-Bridge MMC Converters
Jovcic, D., Lin, W., Nguefeu, S., & Saad, H. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2791635 · Cited by 75
An Improved Phase-Shifted Carrier Modulation Scheme for a Hybrid Modular Multilevel Converter
Lu, S., Yuan, L., Li, K., & Zhao, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2532386 · Cited by 79
“Two major tasks associated with the MMC are the capacitor voltage balance and the circulating current suppression [18], and many papers have been published to tackle these two tasks for the HBSMs-based MMC [19]–[26], the FBSMs-based MMC [27], and the hybrid MMC [15], [17], [28], [29].”
BackgroundElserougi, A. A., Massoud, A. M., & Ahmed, S. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2477684 · Cited by 75
“Various types of cells have been presented in the literature, such as the half-bridge [5]; full-bridge [6]; modified full-bridge [7]; cross-connected SM [7]; clamp double SM [6]; asymmetrical SM [8]; mixed cells [9], [10]; and modified mixed cells [11].”
BackgroundAnalysis and Experiment of a Micro-Loss Multi-Port Hybrid DCCB for MVDC Distribution System
Wen, W., Li, B., Li, B., Liu, H., He, J., Ma, J., & Li, Y. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2881000 · Cited by 68
“2) Using VSC with fault ride through capability [4], [5].”
BackgroundAn Overview of Applications of the Modular Multilevel Matrix Converter
Díaz, M., Cárdenas, R., Ibaceta, E., Mora, A., Urrutia-Ortiz, M., Espinoza, M., Rojas, F., & Wheeler, P. W. (2020) · Energies · doi:10.3390/en13215546 · Cited by 71
“On the other hand, the later topology has been recently reported and discussed in [107,108].”
BackgroundXiang, W., Lin, W., An, T., Wen, J., & Wu, Y. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2607230 · Cited by 64
Dimensioning and Modulation Index Selection for the Hybrid Modular Multilevel Converter
Judge, P. D., Chaffey, G. P., Merlin, M., Clemow, P., & Green, T. C. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2719103 · Cited by 67
“stack can be sized according to the maximum ac line voltage, following the analysis presented in [21].”
BackgroundMethodNew Measuring Technique for Reducing the Number of Voltage Sensors in Modular Multilevel Converters
Picas, R., Zaragoza, J., Pou, J., Ceballos, S., & Balcells, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2412658 · Cited by 62
“is being extensively studied nowadays [21]–[24].”
Analysis and Control of Modular Multilevel Converters under Asymmetric Arm Impedance Conditions
Zeng, R., Xu, L., Yao, L., & Finney, S. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2477057 · Cited by 61
“HE modular multilevel converter (MMC) has drawn attention due to its advantages of modular design, high efficiency and scalability, and excellent output waveforms with low harmonic distortion [1-10].”
BackgroundSelf-citationGhat, M. B., & Shukla, A. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2751680 · Cited by 65
Active Thermal Control for Hybrid Modular Multilevel Converter Under Overmodulation Operation
Sheng, J., Yang, H., Li, C., Chen, M., Li, W., He, X., & Gu, X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2936010 · Cited by 62
“the requirements of riding through dc pole to pole short-circuit fault, according to [12] and [28], the FBSM proportion should satisfy the following conditions:”
BackgroundYang, W., Song, Q., Xu, S., Rao, H., & Liu, W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2722011 · Cited by 62
“For example, for an MMC with N SMs in each arm, if M additional FBSMs are added in each arm and are allowed to generate negative voltage output, the peak ac-side voltage can be extended to 1 + 2M/N times, while the rated dc-link voltage is still N times of the SM capacitor voltages [23].”
BackgroundA Modular Multilevel Converter Integrated With DC Circuit Breaker
Song, Q., Zeng, R., Yu, Z., Liu, W., Huang, Y., Yang, W., & Li, X. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2815550 · Cited by 60
“Hybrid MMCs composed of FBSMs and HBSMs can block the DC fault by using the FBSMs [10], [11].”
BackgroundSelf-citationModular Embedded Multilevel Converter for MV/HVDC Applications
Zhang, D., Dong, D., Datta, R., Rockhill, A., Lei, Q., & Garces, L. J. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2850891 · Cited by 61
Dual Harmonic Injection for Reducing the Submodule Capacitor Voltage Ripples of Hybrid MMC
Xu, J., Weicheng, D., Gao, C., Lu, F., Liang, J., Zhao, C., & Li, G. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3027464 · Cited by 62
A Unidirectional Hybrid HVDC Transmission System Based on Diode Rectifier and Full-Bridge MMC
Li, R., & Xu, L. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3015342 · Cited by 56
“The proposed DFB-MMC is adopted as the rectifier station and operates on power control mode, whilst the HB-MMC of the inverter station controls its DC terminal voltage constant [3].”
InfluentialSelf-citationA Transformerless Hybrid Modular Multilevel DC–DC Converter With DC Fault Ride-Through Capability
Zhang, F., Li, W., & Joós, G. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2869355 · Cited by 56
“SMs for dc–ac application are discussed in [36]–[38].”
BackgroundReview of technologies for DC grids – power conversion, flow control and protection
Adam, G. P., Vrana, T. K., Li, R., Li, P., Burt, G., & Finney, S. J. (2019) · IET Power Electronics · doi:10.1049/iet-pel.2018.5719 · Cited by 58
“A lot of combinations are theoretically possible, but most commonly referred to is a combination of HB and FB cells in order to reduce semiconductor losses to less than that of the FB-MMC [34, 35], while retaining some of the control flexibility of the FB-MMC such as: (a) Resiliency to dc network faults including dc f…”
BackgroundInfluentialKurtoğlu, M., Eroğlu, F., Arslan, A. O., & Vural, A. M. (2018) · International Transactions on Electrical Energy Systems · doi:10.1002/etep.2763 · Cited by 57
Real-Time Device-Level Simulation of MMC-Based MVDC Traction Power System on MPSoC
Liang, T., & Dinavahi, V. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2823059 · Cited by 55
“advantage of dc blocking features but increases the cost of the MMC system [48], [49].”
BackgroundA High-Performance and Economical Multiport Hybrid Direct Current Circuit Breaker
He, J., Luo, Y., Li, M., Zhang, Y., Xu, Y., Zhang, Q., & Luo, G. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2947835 · Cited by 52
“Till now, there are mainly three methods to deal with the dc fault current; using ac circuit breakers [3], using converters with dc fault handing abilities [4], [5], and using dc circuit breakers, yet only the last approach can achieve the required fast and selective fault isolation without voltage collapse and losing…”
MethodOptimal Design of MMC Levels for Electromagnetic Transient Studies of MMC-HVDC
Xu, J., Zhao, C., Xiong, Y., Li, C., Ji, Y., & An, T. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2524648 · Cited by 51
“At the same time the coupled switches S1 are open to remove the dc voltage support during the fault conditions [16].”
BackgroundLee, J.-H., Jung, J.-J., & Sul, S. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896336 · Cited by 53
“According to [14] and [24], the hybrid MMC would have 10% less submodule (SM) cost and 20% less operation loss compared to FBSM-MMC.”
BackgroundResultLiu, Y., Fan, R. L., Zhang, X., Tu, Z., & Zhang, J. (2019) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2018.007861 · Cited by 49
“The low-voltage source is used to charge the MMC capacitors sequentially during the charging mode, which ensures equal current stresses on all switches.”
BackgroundTian, Y., Wickramasinghe, H. R., Li, Z., Pou, J., & Konstantinou, G. S. (2022) · Energies · doi:10.3390/en15061985 · Cited by 66
“This means that an MMC built exclusively with FB-SMs is over-designed, a conclusion which gives rise to a whole family of SMs (as discussed in the following sections) as well as many hybrid configurations for the MMC [29].”
BackgroundProtection of large partitioned MTDC Networks Using DC-DC converters and circuit breakers
Rahman, H., Xu, L., & Yao, L. (2016) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-016-0030-0 · Cited by 51
Self-citationGrid-forming control to achieve a 100% power electronics interfaced power transmission systems
Qoria, T. (2020) · theses.fr (ABES) · doi:10.70675/6a9eeb3aze350z4a47zbbd3zea3bb935e362 · Cited by 68
Bandaru, T., Samajdar, D., Varma, P. B. S., Bhattacharya, T., & Chatterjee, D. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2967277 · Cited by 46
“This is achieved by various methods presented in [6], [11], [13] and [25].”
BackgroundMethodCapacitor voltage ripple reduction with state trajectory analysis for modular multilevel converter
Lyu, Y., Li, C., Hsieh, Y.-H., Lee, F. C., Li, Q., & Xu, R. (2017) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2017.7930947 · Cited by 46
“Finally, a hybrid MMC [7] is addressed as a design trade-off between half bridge MMC and full bridge MMC.”
BackgroundReliability Modeling and Analysis of Hybrid MMCs Under Different Redundancy Schemes
Xie, X., Li, H., McDonald, A., Tan, H., Wu, Y., Yang, T., & Yang, W. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3008281 · Cited by 46
“Therefore, NF should meet the following requirement [7], [12]:”
BackgroundInvestigation of a New Modular Multilevel Converter With DC Fault Blocking Capability
Hu, X., Zhang, J., Xu, S., & Jiang, Y. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2870845 · Cited by 43
An Overview of Modelling Techniques and Control Strategies for Modular Multilevel Matrix Converters
Díaz, M., Cárdenas, R., Ibaceta, E., Mora, A., Urrutia-Ortiz, M., Espinoza, M., Rojas, F., & Wheeler, P. W. (2020) · Energies · doi:10.3390/en13184678 · Cited by 45
Zhang, J., Zhang, Y., Zhou, J., Wang, J., Shi, G., & Cai, X. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3153801 · Cited by 46
“Methods of the first type simply block all the valves in the MMC to interrupt the dc fault current [24], [25].”
DC/DC Converters Based on Hybrid MMC for HVDC Grid Interconnection
Zeng, R., Yao, L., & Xu, L. (2015) · IET International Conference on AC and DC Power Transmission (ACDC) · doi:10.1049/cp.2015.0090 · Cited by 42
“In contrast to the basic hybrid MMC with half half-bridge and half full-bridge SMs in each arm [11, 12], this MMC structure is a simplified configuration by removing an IGBT in the fullbridge SMs (as shown as S3 in Fig.”
BackgroundMethodSelf-citationLu, M., Hu, J., Zeng, R., & He, Z. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2755505 · Cited by 43
“solutions including injecting reactive power [17], increasing the number of FBSMs [20], retrofitting the topology of the hybrid”
BackgroundSelf-citationLow-Capacitance Modular Multilevel Converter Operating With High Capacitor Voltage Ripples
Song, Q., Yang, W., Zhao, B., Meng, J., Xu, S., & Zhu, Z. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2885687 · Cited by 45
“Recent studies have noted that the negative voltage states of full bridge SMs (FBSMs) can be adopted to increase the modulation index and extend the output voltage range [18].”
BackgroundLiu, H., Dahidah, M., Yu, J., Naayagi, R. T., & Armstrong, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2866787 · Cited by 44
“Therefore, it is very important to analyze and understand the stored energy and the power flow between the SMs and/or the converter arms [28], [29].”
BackgroundDong, Y., Tang, J., Yang, H., Li, W., & He, X. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2879915 · Cited by 41
“freewheeling effect, the HBSM MMC lacks the dc fault handling ability, and thus some novel sub-module topologies with the inherent dc fault blocking ability have been proposed [6]–[10].”
BackgroundHu, P., Teodorescu, R., & Guerrero, J. M. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2908828 · Cited by 41
“To some extent, the overmodulation has some benefits, such as increasing the utilization of IGBTs [17] and minimizing the capacitor voltage fluctuation [9].”
BackgroundInfluentialBieber, L. M., Pfannschmidt, J., Wang, L., Nami, A., & Li, W. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2956723 · Cited by 42
“The MB and CDSM MMCs provide a good trade-off between the DC-side fault blocking capability and converter semiconductor loss [17].”
BackgroundYang, J., He, Z., Ke, J., & Xie, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2839117 · Cited by 42
“The design and control strategies on this hybrid concept have been studied thoroughly to get an optimized solution [7]–[10].”
BackgroundLin, L., Lin, Y., Xu, C., & Chen, Y. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2861469 · Cited by 41
“With such a boosted modulation index, ac voltage can be enhanced with a limited dc voltage or keep unchanged with a decreased dc voltage, which can extend the flexibility of MMC [13]–[15].”
BackgroundMethodXu, C., Lin, L., Yin, T., & Hu, J. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2921202 · Cited by 42
“The modulation index M [9] is defined as”
BackgroundNi, X., Zhao, C., Guo, C., Liu, H., & Liu, Y. (2016) · IET Power Electronics · doi:10.1049/iet-pel.2015.0421 · Cited by 38
Experiment on DC-fault Ride Through of MMC Using a Half-Voltage Clamp Submodule
Li, X., Song, Q., Liu, W., Zhu, Z., & Xu, S. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2813329 · Cited by 38
“However, when using the negative voltage state of FBSM, the energy of FBSM and HBSM in one fundamental period differs and hence in order to maintain capacitor voltage balance unbalanced energy should be controlled and transferred between FBSM and HBSM [12].”
MethodLi, Y., Pei, X., Yang, M., Lin, X., & Li, Z. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.2997797 · Cited by 40
“As the maximum modulation index of the hybrid MMC can reach 2 [25], the transformer is not adopted, so that these MMCs can be smaller and operate at higher efficiency.”
BackgroundA Cost-Effective and DC-Fault Tolerant Alternate Arm Converter With Wide Range Voltage Adaptability
Fan, S., Chen, C., Yang, H., Xiang, X., Yang, H., Li, W., & He, X. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3120748 · Cited by 38
“The hybrid-MMC that combines the HBSMs and FBSMs to form the arm stack helps to reduce the device number, but at least 50% FBSMs are still necessary to keep the dc-fault ride-through capability [12]–[14].”
MethodOptimized Design and Control for Hybrid MMC With Reduced Capacitance Requirements
Dong, P., Lyu, J., & Cai, X. (2018) · IEEE Access · doi:10.1109/access.2018.2869400 · Cited by 37
“In order to improve these issues, the hybrid MMC topology based on half-bridge sub-modules (HBSMs) and FB sub-modules (FBSMs) has been investigated by several authors [15]–[21].”
BackgroundChen, G., Hao, P., Zeng, R., Hu, Y., & Ni, K. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2764684 · Cited by 40
“For example, for a MMC system with 20 SMs in each arm, if Y = 8, then the charging ability of driving pulses 1–20 in ascending order is [8, 7, 9, 6, 10, 5, 11, 4, 12, 3, 13, 2, 14, 1, 15, 20, 16, 19, 17, 18].”
Self-citationLi, H., Xie, X., McDonald, A., Chai, Z., Yang, T., Wu, Y., & Yang, W. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.105994 · Cited by 37
Novel Submodule Topology With Large Current Operation and DC-Fault Blocking Capability for MMC-HVDC
Meng, Y., Zou, Y., Wang, H., Kong, Y., Du, Z., & Wang, X. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3011228 · Cited by 38
“Full-bridge submodule (FBSM) topology is able to clear DC-fault current, but its double number of insulated-gate bipolar transistors (IGBT) compared to HBSM also bring the great increase of the investment [22]–[24].”
BackgroundControl and Analysis of the Modular Multilevel DC De-Icer With STATCOM Functionality
Li, B., Shi, S., Xu, D., & Wang, W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2554564 · Cited by 39
“Whereas an MMC with full-bridge SMs, despite having the capability to cut off dc short-circuit current [19], [20], is seldom adopted due to the usage of double number of semiconductors, double semiconductor losses, and the increased cooling investment that followed, when compared to the half-bridge MMC.”
Judge, P. D., Merlin, M., Green, T. C., Trainer, D. R., & Vershinin, K. V. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2843390 · Cited by 36
“In [17], a PG augmented Hybrid MMC [4] was found to have power losses in the region of 0.4% of rated power, and a PG augmented variant of the Extended-Overlap Alternate Arm Converter [18]–[20] was found to achieve power losses in the region of 0.3% of rated power.”
BackgroundInfluentialJudge, P. D., Merlin, M., Green, T. C., Trainer, D. R., & Vershinin, K. V. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2718591 · Cited by 36
“Bridge (FB) SMs in a hybrid design [2], [3].”
A lifting wavelet-based protection strategy against DC line faults for Zhangbei HVDC Grid in China
Kong, M., Pei, X., Pang, H., Yang, J., Dong, X., Wu, Y., & Zhou, X. (2017) · European Conference on Power Electronics and Applications · doi:10.23919/epe17ecceeurope.2017.8099256 · Cited by 36
“The one is based on the fault-self-clearing voltage sourced converter (VSC), such as full-bridge sub-module (FBSM), Clamped Diode Sub-module (CDSM) based modular multilevel converter (MMC) [4-7].”
BackgroundInfluentialReview on topology‐based dc short‐circuit fault ride‐through strategies for MMC‐based HVDC system
Wan, Y., Mao, M., Zhou, L., Xi, X., Xie, B., & Zhou, S. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2019.0607 · Cited by 38
Xu, S., Song, Q., Zhou, Y., Meng, J., Yang, W., Zhao, B., & Zeng, R. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2958495 · Cited by 33
“The dc fault handling of hybrid MMCs is usually implemented by the converter blocking approach [12], [13].”
Self-citationSong, Q., Yang, W., Zhao, B., Xu, S., Rao, H., & Zhu, Z. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2869464 · Cited by 35
“2) Hybrid MMC: For applications that do not require FB-MMC, a hybrid MMC, which combines HBSMs and FBSMs [19], [22], can be used to reduce space requirements using negative states.”
MethodResultXin, Y., Yi, J., Zhang, K., Chen, C., & Xiong, J. (2020) · IEEE Access · doi:10.1109/access.2020.3007022 · Cited by 33
“Nowadays, MMC not only has been widely used in HVDC systems [2], [3], but also in various medium-voltage applications such as battery energy storage [4], medium voltage motor drives [5], MVAC distribution network [6], because of its high-quality output waveform, fewer converter losses, and modularity of structure [7].”
BackgroundA Detailed Review of MMC Circuit Topologies and Modelling Issues
Soomro, J. B., Akhtar, F., Hussain, R., Ansari, J. A., & Munir, H. M. (2022) · International Transactions on Electrical Energy Systems · doi:10.1155/2022/8734010 · Cited by 42
A Cascaded Converter Interfacing Long-Distance HVdc and Back-to-Back HVdc Systems
Xiang, W., Yang, R., Lin, C., Zhou, J., Wen, J., & Lin, W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2913915 · Cited by 33
Zhao, C., Lei, M., Hu, Y., Li, Z., Gao, F., Wang, P., & Li, Y. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2877088 · Cited by 32
“In order to trade off power losses and the fault ride-through capability, the hybrid MMC mixed with HBSMs and FBSMs has been proposed and studied in [17] and [18].”
BackgroundAC fault ride through control strategy on inverter side of hybrid HVDC transmission systems
Zhou, Z., Chen, Z., Wang, X., Dingxiang, D., Yang, G., Wang, Y., & Hao, L. (2019) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-019-0546-1 · Cited by 32
A Hybrid Modular Multilevel Converter With Reduced Full-Bridge Submodules
Li, R., Xu, L., Yu, L., & Yao, L. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2956265 · Cited by 35
“During normal operation, i.e., non-DC fault conditions, the proposed topology operates in the same way as the conventional HB-MMCs including the same AC fault ride-through capability [21].”
BackgroundSelf-citationWald, F., Hrishikesan, V. M., Gomis‐Bellmunt, O., Ji, H., Davoudi, M., Bidram, A., Syed, M. H., Joševski, M., Brüske, S., Kumar, C., et al. (2025) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2025.3574007 · Cited by 43
“…different topologies, most commonly a Modular Multi-level Converter (MMC) is used, which requires complex modulation strategies as reviewed in [29], [30] and additional voltage balancing and common mode compensation controllers are mandatory to ensure stable operation [31], [32], [33], [34].”
Enhanced AC voltage and frequency control of offshore MMC station for wind farm connection
Jing, Y., Li, R., Xu, L., & Wang, Y. (2018) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2018.5391 · Cited by 32
“The arm voltage varm of the MMC station is given as [8]”
MethodSelf-citationZhang, R., Wang, S., Ma, J., Jiang, Y., Wang, P., Liu, T., & Yang, Y. P. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3510792 · Cited by 30
“Based on (24)–(30), we can derive the component parameters for the HB-MMC, the hybrid MMC (H-MMC) incorporating 50% FBSMs [29], and the AHPL-MMC, which are detailed in Table III.”
Review of DC fault protection for HVDC grids
Li, R., & Xu, L. (2017) · Wiley Interdisciplinary Reviews Energy and Environment · doi:10.1002/wene.278 · Cited by 38
“In [24], this ratio is greater than one in order to transfer more power than the conventional MMC by utilizing the negative output voltage capability of the FB SMs.”
BackgroundSelf-citation
Metadata
- Authors
- Zeng, R., Xu, L., Yao, L., & Williams, B. W.
- Affiliations
- University of Strathclyde (GB)
- China Electric Power Research Institute (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-03
- Volume
- 30
- Issue
- 3
- Pages
- 1137-1146
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2008773359
- Cited by
- 455
- References
- 24
- Citations by year
- 2026: 17 · 2025: 31 · 2024: 28 · 2023: 32 · 2022: 30 · 2021: 43 · 2020: 39 · 2019: 61 · 2018: 66 · 2017: 47 · 2016: 41 · 2015: 18
- FWCI
- 18.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) (acceptedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- hybrid modular multilevel converter, full-bridge submodules, half-bridge submodules, DC fault blocking, capacitor voltage balancing, equivalent circuit model, power losses, device utilization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.