Design and Operation of a Hybrid Modular Multilevel Converter
The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Abstract
This paper presents a hybrid modular multilevel converter (MMC), which combines full-bridge submodules (FBSM) and half-bridge submodules (HBSM). Compared with the FBSM-based MMC, the proposed topology has the same dc fault blocking capability but uses fewer power devices hence has lower power losses. To increase power transmission capability of the proposed hybrid MMC, negative voltage states of the FBSMs are adopted to extend the output voltage range. The optimal ratio of FBSMs and HBSMs, and the number of FBSMs generating a negative voltage state are calculated to ensure successful dc fault blocking and capacitor voltage balancing. Equivalent circuits of each arm consisting of two individual voltage sources are proposed and two-stage selecting and sorting algorithms for ensuring capacitor voltage balancing are developed. Comparative studies for different circuit configurations show excellent performance balance for the proposed hybrid MMC, when considering dc fault blocking capability, power losses, and device utilization. Experimental results during normal operation and dc fault conditions demonstrate feasibility and validity the proposed hybrid MMC.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The blocking of a dc fault in an MMC can be achieved when the total voltage of connected submodules along the fault current path is greater than the line-to-line ac voltage [111].”
From Modular Multilevel Converters: Recent Achievements and Challenges (2021) · cites this paper as [111]
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundTu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Self-citationDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 3×
“Thus, in contrast to the conventional capacitor voltage balancing algorithm [2], in which only capacitor voltage and arm current direction are used for SM selection, the selection of SMs in the hybrid MMC has to consider the differences in their behavior, and charging and discharging periods between the FBSMs and HBSM…”
BackgroundMethodResultModulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934 · cited 2×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundMethodShort-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790 · cited 1×
“However, an HBSM-based MMC (HB-MMC) does not have dc fault blocking capability, thus relies on ac or dc circuit breakers to isolate dc faults [13], [14].”
BackgroundMarquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundIlves, K., Antonopoulos, A., Norrga, S., & Nee, H.-P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159809 · Cited by 578 · cited 1×
“The half-bridge based SM (HBSM) has been the main configuration in the MMC [1-7].”
BackgroundA Steady-State Analysis Method for a Modular Multilevel Converter
Song, Q., Liu, W., Li, X., Rao, H., Xu, S., & Li, L. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227818 · Cited by 503 · cited 2×
“A detailed analysis on the impact of the circulating current on capacitor voltage ripple is provided in [23].”
Background
Research works printed but not linked: 1
- backlund, 2012, Data sheet IGBT module 5SNA 1200G450300
Cited by
Li, R., Xu, L., & Yao, L. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2590501 · Cited by 350
“FOR a large multiterminal HVDC system, in the event of a dc fault, it is desirable that the converters connected to the healthy dc lines continue operating without disruption while the faulty branches are quickly isolated [1]–[3].”
BackgroundSelf-citationModular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“current path is greater than the line-to-line ac voltage [111].”
BackgroundFull-Bridge MMC Converter Optimal Design to HVDC Operational Requirements
Lin, W., Jovcic, D., Nguefeu, S., & Saad, H. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2475130 · Cited by 224
“Such topology is named mixed cells MMC in [19] or hybrid MMC in [20]-[21].”
BackgroundCui, S., & Sul, S.-K. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2513426 · Cited by 210
Precharging and DC Fault Ride-Through of Hybrid MMC-Based HVDC Systems
Zeng, R., Xu, L., Yao, L., & Morrow, D. J. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2360042 · Cited by 180
“The basic operation of this MMC configuration, including capacitor voltage balancing, has been analyzed in [17], so this paper will focus on the precharging process of the hybrid MMC and its ride-through capability under a transient dc fault, both of which are vital to the operation of the converter.”
BackgroundMethodSelf-citation
Metadata
- Authors
- Zeng, R., Xu, L., Yao, L., & Williams, B. W.
- Affiliations
- University of Strathclyde (GB)
- China Electric Power Research Institute (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-03
- Volume
- 30
- Issue
- 3
- Pages
- 1137-1146
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2008773359
- Cited by
- 455
- References
- 24
- Citations by year
- 2026: 17 · 2025: 31 · 2024: 28 · 2023: 32 · 2022: 30 · 2021: 43 · 2020: 39 · 2019: 61 · 2018: 66 · 2017: 47 · 2016: 41 · 2015: 18
- FWCI
- 18.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) (acceptedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Keywords
- hybrid modular multilevel converter, full-bridge submodules, half-bridge submodules, DC fault blocking, capacitor voltage balancing, equivalent circuit model, power losses, device utilization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.