Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies
The DOI matches its Crossref record; 31 of the 33 references it cites were found in a registry or an index.
Abstract
Compared with conventional power transformer, power electronic transformer (PET) has many merits and an increasing possibility to replace it in the future. In this paper, the unbalanced-load correction capability of two H-bridge based three-phase three-stage modular PET topologies, the separate-phase-connection (SPC) one and the cross-phase-connection (CPC) one, are analyzed and compared. Both of the SPC and CPC consist of three stages: a modular multilevel ac-dc input stage, an isolation stage with several independent modular dual active bridge (DAB) dc-dc converters, and a dc-ac output stage with single-phase-inverter parallel-connected structure. Based on the control strategy, it is found that the SPC is suitable for dealing with full-range unbalanced load under the condition of increasing the input-stage current stress. For the SPC feeding, one load or three loads with identical power polarity, the current stress shall be theoretically increased up to 115% of the rated one, while the percentage is 153% when the SPC feeds three loads with different power polarity. On the contrary, the CPC is only suitable for dealing with partial unbalanced-load conditions. Extendedly, the third so-called full-range-power auto-balance PET is proposed to deal with unbalanced load, the performance of which is verified by simulation results. A downscaled prototype for SPC and CPC is built and tested. Experimental results verify the unbalanced-load correction performance of SPC and CPC.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715 · cited 1×
“The recent advances of high-voltage high-power multilevel converters have been discussed in [21]–[23].”
BackgroundA three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535 · cited 2×
“Phase-shift control described in detail in [30] is applied for DAB to regulate its associated output-stage-side dclink voltage.”
BackgroundMethodThe Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463 · cited 1×
“In the past decades, the increasing penetration of renewable energy (especially the wind power generation) [3]–[5] and the fast development of smart grid [6]–”
BackgroundClassification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172 · cited 1×
“For an H-bridge cascaded multilevel converter, an interfacing inductor normally serves as the input filter connected between the converter and power grid [13]–[15], [17], [18], [22], [23] [31]–[33].”
BackgroundReview of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164 · cited 3×
“Various PET topologies for different applications are proposed in [1], [2], and [8]–[18], most of which focus on single-”
BackgroundFuture on Power Electronics for Wind Turbine Systems
Blaabjerg, F., & Ma, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2275978 · Cited by 860 · cited 1×
“For an H-bridge cascaded multilevel converter, an interfacing inductor normally serves as the input filter connected between the converter and power grid [13]–[15], [17], [18], [22], [23] [31]–[33].”
BackgroundControl and Performance of a Transformerless Cascade PWM STATCOM With Star Configuration
Akagi, H., Inoue, S., & Yoshii, T. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900487 · Cited by 643 · cited 3×
“Different control strategies focusing on dc-link voltage balancing are proposed for H-bridge cascade multilevel converter based static synchronous compensator (STATCOM) in [31]– [33].”
BackgroundVoltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642 · cited 4×
“it attracted increasing interest from both academia and industry, and significant progress was made in the last two decades [5]–[18].”
BackgroundInfluentialFalcones, S., Ayyanar, R., & Mao, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215965 · Cited by 501
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401 · cited 1×
“[27] proposed dual-half-bridge dc–dc converter modules with high efficiency over wide load range for PET.”
Background
Research works printed but not linked: 1
- du, 0, High-voltage high-frequency transformer design for a 7.2�kV to 120�V/240�V 20 kVA solid state transformer, Proc IEEE 36th Annu Ind Electron Conf, 493
Cited by
Minimum-Backflow-Power Scheme of DAB-Based Solid-State Transformer With Extended-Phase-Shift Control
Shi, H., Wen, H., Chen, J., Hu, Y., Jiang, L., Chen, G., & Ma, J. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2819120 · Cited by 250
Liu, J., Yang, J., Zhang, J., Nan, Z., & Zheng, Q. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2679489 · Cited by 146
“Erenow, there are many similar researches, not only in traction onboard application, but also in the utility gird application, and the concepts such as solid-state transformer [8], universal and flexible power management [9], power electronic transformer [10], smart energy router [11], [12], single-phase solid-state p…”
BackgroundSelf-citationLiu, Y., Liu, Y., Ge, B., & Abu‐Rub, H. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2679137 · Cited by 60
“The multistage SST based on dual active bridge (DAB) comprises high-voltage (HV) side ac–dc rectification, intermediate high-frequency (HF) dc–dc conversion, and low-voltage (LV) side dc–ac inversion [6]–[16].”
BackgroundMethodZheng, L., Kandula, R. P., & Divan, D. M. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3211000 · Cited by 58
“utility distribution systems [1], [2], [3], [4], [5], [6], [7], [8], using medium-voltage (MV) SiC devices [9], [10], [11].”
Zheng, L., Han, X., Xu, C., Kandula, R. P., Graber, L., Saeedifard, M., & Divan, D. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3172946 · Cited by 42
“, hard-switched rectifiers and inverters coupled with an isolated bidirectional dc/dc converter (IBDC) [3], [4].”
BackgroundNie, J., Yuan, L., Wen, W., Duan, R., Shi, B., & Zhao, Z. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2936109 · Cited by 41
“Differently from most three-stage SSTs whose first stage is a PWM rectifier, DAB stage is used to regulate right side dc voltage, and inverter stage is used to stabilize output ac voltage [7], [25], [26], the dc bus voltage udc in Fig.”
Qu, Z., Yao, Y., Wang, Y., Zhang, C., Chong, Z., & Abu‐Siada, A. (2019) · IEEE Access · doi:10.1109/access.2019.2933414 · Cited by 32
“However, topology design method will increase the complexity of the circuit and raise the cost [15], [16].”
MethodZheng, L., Kandula, R. P., Kandasamy, K., & Divan, D. M. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3101811 · Cited by 26
Tian, J., Hu, D., Zhou, C., Yang, Y., Wu, W., Mao, C., & Wang, D. (2019) · IEEE Access · doi:10.1109/access.2019.2905006 · Cited by 17
“This strategy has been presented in [20] and [21].”
BackgroundMethodDC-Link Current Minimization Control for Current Source Converter-Based Solid-State Transformer
Zheng, L., Han, X., Kandula, R. P., & Divan, D. M. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3178433 · Cited by 14
Wang, Q., & Liang, D. (2016) · International Conference on Ecological Vehicles and Renewable Energies (EVER) · doi:10.1109/ever.2016.7476340 · Cited by 14
Ouyang, S., Liu, J., & Chen, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3075085 · Cited by 11
“Using the ZS current injection, the -CHB can achieve full-range compensation at a cost of only 15% extra current capacity [13], which makes -CHB a better choice for active-power applications, such as PV [14], BESS, and SST without LVdc [15], as well as the STATCOM that mainly”
MethodSelf-citationA triple port active bridge converter based multi-fed power electronic transformer
Jakka, V. N. S. R., & Shukla, A. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854797 · Cited by 11
“Multilevel converters and modern semiconductor devices can be employed in PET technology to achieve medium voltage operation [7]-[9].”
BackgroundOuyang, S., Liu, J., Wang, X., Song, S., Hou, X., & Wu, T. (2015) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.1109/icpe.2015.7168166 · Cited by 10
Self-citationDesign and Implementation of 10-kV MW-level Electronic Power Transformer (EPT)
Wang, D., Yang, Y., Tian, J., Mao, C., & Zhang, J. (2018) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2018.8544706 · Cited by 9
“In [13] and [14], the unbalanced operation of EPT has been analyzed.”
BackgroundComparison of four power electronic transformer topologies on unbalanced load correction capacity
Ouyang, S., Liu, J., Wang, X., Song, S., & Hou, X. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310183 · Cited by 7
Self-citationResearch on power electronic transformer applied in AC/DC hybrid distribution networks
Miao, Y., Song, J., Liu, H., Lu, Z., Chen, S., Chun, D., Cao, T., Cai, L., & Gong, Y. (2018) · DOAJ (DOAJ: Directory of Open Access Journals) · doi:10.14171/j.2096-5117.gei.2018.03.012 · Cited by 5
Jakka, V. N. S. R., & Shukla, A. (2016) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2016.7695500 · Cited by 5
“The outputs of DABs are connected in parallel across the dc-link of the output stage inverter.”
BackgroundPower electronic transformer with adaptive PLL technique for voltage-disturbance ride through
Wang, J., Luo, F., Duan, Q., Ji, Z., Gu, B., You, J., Gu, W., & Zhao, J. (2018) · Journal of Modern Power Systems and Clean Energy · doi:10.1007/s40565-017-0356-2 · Cited by 5
Zhang, Y., Liu, C., Sun, L. Q., & Zhi, Y. (2016) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec.2016.7779519 · Cited by 5
“In [7] both of input-stage control and output-stage control have been used to achieve PET work under the unbalanced-load situation.”
BackgroundMethodDesign and software implementation of solid state transformer
Hassan, R. F. (2018) · International Journal of Engineering & Technology · doi:10.14419/ijet.v7i3.16423 · Cited by 6
“In addition to performing the same task as traditional transformer, employing SST opens up a new horizon in the utilization of electrical power systems [5].”
BackgroundMethodLi, J., Wu, J., & Xiong, F. B. (2024) · Energies · doi:10.3390/en17051096 · Cited by 5
Solar Photovoltaic Supply System Integrated with Solid State Transformer
Sharma, R., & Sharma, S. K. (2021) · IEEE International Conference on Computing, Power and Communication Technologies (IC2PCT) · doi:10.1109/gucon50781.2021.9573638 · Cited by 4
Du, S., Wang, Z., & Liu, J. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3393136 · Cited by 3
“However, it still faces great challenges in resisting grid-fault deployment especially under renewable-devices-integration conditions [5].”
BackgroundSelf-citationResearch on cluster operation optimization of multi‐port energy routers
Xu, X., Tai, N., Hu, Y. Q., Zheng, X., & Qing, C. (2022) · IET Communications · doi:10.1049/cmu2.12388 · Cited by 2
Design and Implementation of Three-phase to single-phase AC Solid State Transformer
Ding, J. (2021) · doi:10.1109/cpeee51686.2021.9383373 · Cited by 2
Reactive component injection control of the modular multi-output power electronic transformer
Ouyang, S., Liu, J., Song, S., & Chen, X. (2016) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec.2016.7846187 · Cited by 1
“In recent years two PETs of such connection are published [3][4].”
BackgroundSelf-citationDai, M., Xu, P., Liang, X. P., Zhu, X., Liu, X., Liu, X., Han, P., & Wu, C. (2023) · Microelectronics International · doi:10.1108/mi-07-2022-0118 · Cited by 2
Wong, H. M., Huang, W., & Yin, L. (2019) · Journal of Power Electronics · doi:10.6113/jpe.2019.19.2.487 · Cited by 5
Study on Optimal Operation of Multi-Port Cascaded Power Electronic Transformer Cluster
Xu, X., Tai, N., Hu, Y., Liu, T., Fan, C., & Geng, Q. (2019) · IEEE Sustainable Power and Energy Conference (iSPEC) · doi:10.1109/ispec48194.2019.8975033 · Cited by 2
Cross phases hybrid transformer for managing and improving the energy quality
Díaz-Ojeda, M., Rodriguez‐Rodrıguez, J. R., Hernández-Sánchez, J., Trillaud, F., Olivares-Galvan, J. C., & Escarela-Pérez, R. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107005 · Cited by 1
Design and Implementation of the Isolated Bidirectional DC-DC Converter
Yuan, Y. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2125/1/012056 · Cited by 2
Using an Integrated Script Control Unit (ISCU) to Assist the Power Electronics Education
Gao, Z., & Lu, Q. (2017) · Energies · doi:10.3390/en10111802
Yin, H., Liu, Y., Li, Q., Liu, X., Gao, H., & Liu, J. (2020) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei250167.2020.9347219
Self-citationDesign of three-stage power electronic transformer for smart grid
Li, J. (2021) · International Conference on Electrical Engineering and Mechatronics Technology (ICEEMT) · doi:10.1109/iceemt52412.2021.9602125
Dai, M., Tang, J., Xu, P., Han, P., Zhu, X., An, S., & Yang, G. (2022) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea54703.2022.10006137
Jenopaul, P., & Praveen, B. M. (2025) · International Conference on Circuit, Power and Computing Technologies · doi:10.1109/iccpct65132.2025.11176709
Metadata
- Authors
- Wang, X., Liu, J., Ouyang, S., & Meng, F.
- Affiliations
- State Key Laboratory of Electrical Insulation and Power Equipment (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-06
- Volume
- 30
- Issue
- 6
- Pages
- 3044-3056
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2027201238
- Cited by
- 37
- References
- 33
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 5 · 2021: 7 · 2020: 1 · 2019: 5 · 2018: 5 · 2017: 3 · 2016: 5 · 2015: 2
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- U.S. Department of Commerce
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- solid-state transformer, H-bridge topology, modular multilevel converter, dual active bridge converter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.