Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies
The DOI matches its Crossref record; 31 of the 33 references it cites were found in a registry or an index.
Abstract
Compared with conventional power transformer, power electronic transformer (PET) has many merits and an increasing possibility to replace it in the future. In this paper, the unbalanced-load correction capability of two H-bridge based three-phase three-stage modular PET topologies, the separate-phase-connection (SPC) one and the cross-phase-connection (CPC) one, are analyzed and compared. Both of the SPC and CPC consist of three stages: a modular multilevel ac-dc input stage, an isolation stage with several independent modular dual active bridge (DAB) dc-dc converters, and a dc-ac output stage with single-phase-inverter parallel-connected structure. Based on the control strategy, it is found that the SPC is suitable for dealing with full-range unbalanced load under the condition of increasing the input-stage current stress. For the SPC feeding, one load or three loads with identical power polarity, the current stress shall be theoretically increased up to 115% of the rated one, while the percentage is 153% when the SPC feeds three loads with different power polarity. On the contrary, the CPC is only suitable for dealing with partial unbalanced-load conditions. Extendedly, the third so-called full-range-power auto-balance PET is proposed to deal with unbalanced load, the performance of which is verified by simulation results. A downscaled prototype for SPC and CPC is built and tested. Experimental results verify the unbalanced-load correction performance of SPC and CPC.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715 · cited 1×
“The recent advances of high-voltage high-power multilevel converters have been discussed in [21]–[23].”
BackgroundA three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535 · cited 2×
“Phase-shift control described in detail in [30] is applied for DAB to regulate its associated output-stage-side dclink voltage.”
BackgroundMethodThe Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463 · cited 1×
“In the past decades, the increasing penetration of renewable energy (especially the wind power generation) [3]–[5] and the fast development of smart grid [6]–”
BackgroundClassification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172 · cited 1×
“For an H-bridge cascaded multilevel converter, an interfacing inductor normally serves as the input filter connected between the converter and power grid [13]–[15], [17], [18], [22], [23] [31]–[33].”
BackgroundReview of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164 · cited 3×
“Various PET topologies for different applications are proposed in [1], [2], and [8]–[18], most of which focus on single-”
BackgroundFuture on Power Electronics for Wind Turbine Systems
Blaabjerg, F., & Ma, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2275978 · Cited by 860 · cited 1×
“For an H-bridge cascaded multilevel converter, an interfacing inductor normally serves as the input filter connected between the converter and power grid [13]–[15], [17], [18], [22], [23] [31]–[33].”
BackgroundControl and Performance of a Transformerless Cascade PWM STATCOM With Star Configuration
Akagi, H., Inoue, S., & Yoshii, T. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900487 · Cited by 643 · cited 3×
“Different control strategies focusing on dc-link voltage balancing are proposed for H-bridge cascade multilevel converter based static synchronous compensator (STATCOM) in [31]– [33].”
BackgroundVoltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642 · cited 4×
“it attracted increasing interest from both academia and industry, and significant progress was made in the last two decades [5]–[18].”
BackgroundInfluentialFalcones, S., Ayyanar, R., & Mao, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215965 · Cited by 501
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401 · cited 1×
“[27] proposed dual-half-bridge dc–dc converter modules with high efficiency over wide load range for PET.”
BackgroundAnalysis and design of electronic transformers for electric power distribution system
Kang, M., Enjeti, P. N., & Pitel, I. J. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.803407 · Cited by 365
Research on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362 · cited 2×
“In [17], [18], and [28], different control strategies are proposed for the same single-”
BackgroundAdvanced Power Electronic Conversion and Control System for Universal and Flexible Power Management
Bifaretti, S., Zanchetta, P., Watson, A., Tarisciotti, L., & Clare, J. C. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2115260 · Cited by 339
Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324
A power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
Solid-State Transformer Architecture Using AC–AC Dual-Active-Bridge Converter
Qin, H., & Kimball, J. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2204710 · Cited by 310 · cited 1×
“energy resources, and distributed energy storage devices [11].”
BackgroundMaharjan, L., Inoue, S., & Akagi, H. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.2002180 · Cited by 310 · cited 7×
“For an H-bridge cascaded multilevel converter, an interfacing inductor normally serves as the input filter connected between the converter and power grid [13]–[15], [17], [18], [22], [23] [31]–[33].”
BackgroundInfluentialPower Electronic Traction Transformer-Low Voltage Prototype
Dujic, D., Zhao, C., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2248756 · Cited by 293 · cited 2×
“In [12] and [13], two single-phase PET topologies both with one low-voltage dc bus and associated control strategies are proposed for railway traction application.”
BackgroundCombining the Wind Power Generation System With Energy Storage Equipment
Lu, M.-S., Chang, C.-L., Lee, W.-J., & Wang, L. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2031937 · Cited by 254 · cited 1×
“In the past decades, the increasing penetration of renewable energy (especially the wind power generation) [3]–[5] and the fast development of smart grid [6]–”
BackgroundEvolving and Emerging Applications of Power Electronics in Systems
Kassakian, J. G., & Jahns, T. M. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2271111 · Cited by 230
Multilevel intelligent universal transformer for medium voltage applications
Lai, J.-S., Maitra, A., Mansoor, A., & Goodman, F. (2005) · Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005. · doi:10.1109/ias.2005.1518705 · Cited by 185
She, X., Huang, A. Q., Wang, F., & Burgos, R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2216245 · Cited by 161
A Transformerless D-STATCOM Based on a Multivoltage Cascade Converter Requiring No DC Sources
Sano, K., & Takasaki, M. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2174383 · Cited by 155
Du, Y., Baek, S., Bhattacharya, S., & Huang, A. Q. (2010) · IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2010.5674828 · Cited by 120 · cited 2×
“[26] reviewed and compared different magnetic core materials for PET high-voltage high-frequency transformer, and a 3-kHz 6.”
BackgroundShe, X., Huang, A. Q., & Ni, X. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2256149 · Cited by 119 · cited 3×
“[28] proposed a current sensorless power balance strategy for the dc–”
BackgroundA Novel DC Voltage Control Method for STATCOM Based on Hybrid Multilevel H-Bridge Converter
Du, S., Liu, J., Lin, J., & He, Y. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2195508 · Cited by 117
Self-citationPower electronics traction transformer
Hugo, N., Stefanutti, P., Pellerin, M., & Akdag, A. (2007) · 2007 European Conference on Power Electronics and Applications · doi:10.1109/epe.2007.4417649 · Cited by 112
Wu, Y., Lee, C.-Y., & Shu, G.-H. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2125933 · Cited by 42
Gupta, R. K., Castelino, G. F., Mohapatra, K. K., & Mohan, N. (2009) · 2009 35th Annual Conference of IEEE Industrial Electronics · doi:10.1109/iecon.2009.5414881 · Cited by 39 · cited 1×
“In [5] and [24], single-stage and three-stage PET topologies as the interface between the wind power generator and power grid”
BackgroundWang, X., Liu, J., Xu, T., & Wang, X. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342648 · Cited by 29
Self-citationComparison of 10-kV SiC power devices in solid-state transformer
Wang, J., Wang, G., Bhattacharya, S., & Huang, A. Q. (2010) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2010.5617759 · Cited by 23 · cited 1×
“On the other hand, silicon carbide (SiC) based power semiconductor devices for high-voltage high-power PET are investigated in [19] and [20].”
Background
Research works printed but not linked: 1
- du, 0, High-voltage high-frequency transformer design for a 7.2�kV to 120�V/240�V 20 kVA solid state transformer, Proc IEEE 36th Annu Ind Electron Conf, 493
Cited by
Minimum-Backflow-Power Scheme of DAB-Based Solid-State Transformer With Extended-Phase-Shift Control
Shi, H., Wen, H., Chen, J., Hu, Y., Jiang, L., Chen, G., & Ma, J. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2819120 · Cited by 250
Liu, J., Yang, J., Zhang, J., Nan, Z., & Zheng, Q. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2679489 · Cited by 146
“Erenow, there are many similar researches, not only in traction onboard application, but also in the utility gird application, and the concepts such as solid-state transformer [8], universal and flexible power management [9], power electronic transformer [10], smart energy router [11], [12], single-phase solid-state p…”
BackgroundSelf-citationLiu, Y., Liu, Y., Ge, B., & Abu‐Rub, H. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2679137 · Cited by 60
“The multistage SST based on dual active bridge (DAB) comprises high-voltage (HV) side ac–dc rectification, intermediate high-frequency (HF) dc–dc conversion, and low-voltage (LV) side dc–ac inversion [6]–[16].”
BackgroundMethodZheng, L., Kandula, R. P., & Divan, D. M. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3211000 · Cited by 58
“utility distribution systems [1], [2], [3], [4], [5], [6], [7], [8], using medium-voltage (MV) SiC devices [9], [10], [11].”
Zheng, L., Han, X., Xu, C., Kandula, R. P., Graber, L., Saeedifard, M., & Divan, D. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3172946 · Cited by 42
“, hard-switched rectifiers and inverters coupled with an isolated bidirectional dc/dc converter (IBDC) [3], [4].”
Background
Metadata
- Authors
- Wang, X., Liu, J., Ouyang, S., & Meng, F.
- Affiliations
- State Key Laboratory of Electrical Insulation and Power Equipment (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-06
- Volume
- 30
- Issue
- 6
- Pages
- 3044-3056
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2027201238
- Cited by
- 37
- References
- 33
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 5 · 2021: 7 · 2020: 1 · 2019: 5 · 2018: 5 · 2017: 3 · 2016: 5 · 2015: 2
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- U.S. Department of Commerce
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Keywords
- solid-state transformer, H-bridge topology, modular multilevel converter, dual active bridge converter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.