Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Grid synchronization stability issues and subsynchronous oscillations between synchronous generators exist in electrical power systems. Three-phase voltage-source converters (VSCs) are being installed more and more in the grid to improve efficiency or to utilize renewable energy sources. The same stability issues between VSCs are also reported and analyzed using a small-signal model of phase-locked loops (PLLs). This paper proposes a different impedance-based analysis method. The proposed method shows that synchronization instability in a VSC system is due to the negative incremental resistance behavior of grid-tied inverters' impedance when they are modeled in the d-q frame. System can be stabilized simply by changing the inverter's PLL design. Experimental results verify the analysis and the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multivariable Feedback Control: Analysis and Design
Skogestad, S., & Postlethwaite, I. (1996) · Cited by 6,312
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334
Self-citationA phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Input filter considerations in design and application of switching regulators.
Middlebrook, R. D. (1976) · Medical Entomology and Zoology · Cited by 1,180
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117
Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861185 · Cited by 1,101
Cited by
Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334
Self-citationTaul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2892142 · Cited by 415
Large Signal Synchronizing Instability of PLL-Based VSC Connected to Weak AC Grid
Hu, Q., Fu, L., Ma, F., & Ji, F. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2892224 · Cited by 398
Lyu, J., Zhang, X., Cai, X., & Molinas, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2842682 · Cited by 345
Couplings in Phase Domain Impedance Modelling of Grid-Connected Converters
Bakhshizadeh, M. K., Wang, X., Blaabjerg, F., Hjerrild, J., Kocewiak, L., Bak, C. L., & Hesselbek, B. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2542244 · Cited by 302
Frequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Lyu, J., Cai, X., & Molinas, M. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2498182 · Cited by 267
“The d–q impedances of two-level grid-connected inverters with feedback control and PLL were derived and measured in [20]–[22], and an impedance-based stability analysis for three-phase gridconnected paralleled converters was performed in [22].”
MethodZhang, X., Xia, D., Fu, Z., Wang, G., & Xu, D. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2811718 · Cited by 262
Grid-Synchronization Stability Improvement of Large Scale Wind Farm During Severe Grid Fault
Ma, S., Geng, H., Liu, L., Yang, G., & Pal, B. C. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2700050 · Cited by 261
Huang, L., Xin, H., Li, Z., Ju, P., Yuan, H., Lan, Z., & Wang, Z. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2924295 · Cited by 252
Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid
Zhu, D., Zhou, S., Zou, X., & Kang, Y. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2943634 · Cited by 225
“Then, the minor loop gain L(s) can be expressed as [33]”
BackgroundCatalán, P., Wang, Y., Arza, J., & Chen, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3234221 · Cited by 197
Power electronics - the key technology for renewable energy system integration
Blaabjerg, F., Yang, Y., Ma, K., & Wang, X. (2015) · 2015 International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2015.7418680 · Cited by 148
“More important, in respect to the aforementioned control methods for WTSs and PV systems, a fast and accurate synchronization system will contribute to the dynamic performance and potentially the stability margin of the whole control systems, as recently investigated in [46].”
Background
Metadata
- Authors
- Wen, B., Dong, D., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-01
- Volume
- 31
- Issue
- 1
- Pages
- 26-38
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2072513313
- Cited by
- 586
- References
- 22
- FWCI
- 39.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.