Reliability Analysis and Redundancy Configuration of MMC With Hybrid Submodule Topologies
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Modular multilevel converter (MMC) has become the most promising converter technology for high-voltage direct current (HVdc) transmission systems. MMC submodule (SM) topologies with dc fault ride-through capabilities are emerging which are suitable for overhead line applications. The hybrid SM design of each converter arm can get the compromise of higher capability of handling dc fault and lower capital investments and losses. In this paper, the initial hybrid SM numbers design method for supporting the dc-link voltage and riding-through dc faults and the optimized hybrid SM redundancy configuration strategy for effectively increasing the reliability of MMC are proposed and calculated. In contrast with the previously proposed redundancy configuration for MMC with the single SM topology, this approach solves the curvature of three-dimensional surface to calculate the recommended redundant hybrid SM numbers which takes both the semiconductor device utilization rate and the reliability of MMC into consideration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 1×
“2, respectively, represents the half-bridge SM (HBSM) [12], the fullbridge SM (FBSM) [13], the clamp double SM (CDSM) [14], the clamp single SM (CSSM) [15], and the improved hybrid SM (IHSM) [16].”
Circuit Topologies, Modeling, Control Schemes, and Applications of Modular Multilevel Converters
Perez, M. A., Bernet, S., Rodriguez, J., Kouro, S., & Lizana, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310127 · Cited by 1,346 · cited 1×
“Compared with the conventional two- and three-level voltage-sourced converters (VSC), the MMC topology offers more advantages such as [1], [2]: 1) its modular design permits easier scalability to any desired voltage and power levels simply by including a larger or smaller number of modules; 2) output voltage waveform…”
Dynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188
Modular Multilevel Converters for HVDC Applications: Review on Converter Cells and Functionalities
Nami, A., Liang, J., Dijkhuizen, F., & Demetriades, G. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2327641 · Cited by 1,042 · cited 1×
“MODULAR multilevel converter-based high-voltage direct current (MMC-HVdc) transmission is gaining in popularity as a dc power transmission option [1]–[4].”
Marquardt, R. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5544594 · Cited by 773 · cited 5×
“2, respectively, represents the half-bridge SM (HBSM) [12], the fullbridge SM (FBSM) [13], the clamp double SM (CDSM) [14], the clamp single SM (CSSM) [15], and the improved hybrid SM (IHSM) [16].”
InfluentialDesign and Operation of a Hybrid Modular Multilevel Converter
Zeng, R., Xu, L., Yao, L., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320822 · Cited by 455 · cited 1×
“Therefore, the hybrid MMCs with different SM topologies are emerging as shown in [17]–[19], and normally the HBSM is selected as the fundamental SM topology to support the dclink voltage and the other SMs with higher DFRTI values are responsible for cutting off the dc fault currents.”
Modular Multilevel Converter topologies with DC-Short circuit current limitation
Marquardt, R. (2011) · 8th International Conference on Power Electronics - ECCE Asia · doi:10.1109/icpe.2011.5944451 · Cited by 413 · cited 1×
“2, respectively, represents the half-bridge SM (HBSM) [12], the fullbridge SM (FBSM) [13], the clamp double SM (CDSM) [14], the clamp single SM (CSSM) [15], and the improved hybrid SM (IHSM) [16].”
Hybrid Design of Modular Multilevel Converters for HVDC Systems Based on Various Submodule Circuits
Qin, J., Saeedifard, M., Rockhill, A., & Zhou, R. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2351794 · Cited by 358 · cited 2×
“[8] considered the topology design only and did not include the reliability analysis and redundancy configurations of the hybrid MMC.”
On Energy Storage Requirements in Modular Multilevel Converters
Ilves, K., Norrga, S., Harnefors, L., & Nee, H.-P. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254129 · Cited by 353 · cited 2×
“MODULAR multilevel converter-based high-voltage direct current (MMC-HVdc) transmission is gaining in popularity as a dc power transmission option [1]–[4].”
Precharging and DC Fault Ride-Through of Hybrid MMC-Based HVDC Systems
Zeng, R., Xu, L., Yao, L., & Morrow, D. J. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2360042 · Cited by 180
Accelerated Model of Modular Multilevel Converters in PSCAD/EMTDC
Xu, J., Zhao, C., Liu, W., & Guo, C. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2201511 · Cited by 177
Self-citationThe Use of Averaged-Value Model of Modular Multilevel Converter in DC Grid
Xu, J., Gole, A. M., & Zhao, C. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2332557 · Cited by 176
Self-citationPicas, R., Pou, J., Ceballos, S., Zaragoza, J., Konstantinou, G., & Agelidis, V. G. (2013) · 2013 IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia.2013.6579115 · Cited by 157 · cited 1×
“The controller shown in [11] is used to suppress the circulating second harmonic current among the phase units.”
Li, R., Adam, G. P., Holliday, D., Fletcher, J., & Williams, B. W. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2389758 · Cited by 137
DC faults ride-through capability analysis of Full-Bridge MMC-MTDC System
Zhao, C., Xu, J., & Li, T. (2012) · Science China Technological Sciences · doi:10.1007/s11431-012-5043-y · Cited by 36 · cited 13×
“Previously, the DFTRI was proposed to evaluate the dc fault current clearing capabilities of MMC [9].”
InfluentialSelf-citationA Sub-Module Topology of MMC With DC Fault Ride-Through Capability
Pengha, Z. (2014) · Power System Technology · Cited by 15
A Method for Calculating Sub-module Redundancy Configurations in Modular Multilevel Converters
Xu, J. (2013) · Dianli xitong zidonghua · Cited by 10
Self-citation
Cited by
Xu, L., Guerrero, J., Lashab, A., Wei, B., Bazmohammadi, N., Vasquez, J., & Abusorrah, A. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3128417 · Cited by 262
“Fault tolerance × √ [129] × [130] Fault ride-through capability × × [131] √ [131] × [132]”
Chang, F., Ilina, O., Lienkamp, M., & Voss, L. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2854756 · Cited by 111
“For the CHB, since the voltage of each module is below 60 V and considered to be in low voltage range, it is not necessarily required to have contactors on the batteries [67].”
BackgroundReliability Modeling of MMCs Considering Correlations of the Requisite and Redundant Submodules
Xu, J., Jing, H., & Zhao, C. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2757607 · Cited by 53
“6703, which is very close to the results obtained from the classical probability based MMC reliability models [9].”
MethodResultInfluentialSelf-citationThe Predictive Closed-Loop Averaging Control of MMC Phase-Unit Losses Under Unbalanced Conditions
Xu, J., Yu, Y., & Zhao, C. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2868772 · Cited by 14
Self-citation
Metadata
- Authors
- Xu, J., Zhao, P., & Zhao, C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-04
- Volume
- 31
- Issue
- 4
- Pages
- 2720-2729
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2179837950
- Cited by
- 179
- References
- 17
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.