An Open-Switch Fault Diagnosis Method for Single-Phase PWM Rectifier Using a Model-Based Approach in High-Speed Railway Electrical Traction Drive System
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The converter with a single-phase rectifier, a dc-link circuit and a three-phase inverter is widely applied in high-speed railway electrical traction drive system. The fault frequency of single-phase rectifier is higher than that of three-phase inverter. Thus, this paper presents a new and fast model-based approach for open-switch fault diagnosis of the single-phase pulse width modulation rectifier, based on the mixed logical dynamic model and residual generation. It requires no additional hardware but only some measurements and command signals which are available in control system. This diagnosis method is quite suitable for electrical traction application due to the fast diagnosis time, simple structure and high reliability. Experimental results confirm the effectiveness and accuracy of the proposed algorithm. It is shown that such diagnosis method can locate the faulty switch in a few milliseconds which is important to avoid catastrophic consequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of systems integrating logic, dynamics, and constraints
Bemporad, A., & Morari, M. (1999) · Automatica · doi:10.1016/s0005-1098(98)00178-2 · Cited by 3,066
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441
Fault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361 · cited 1×
“A fault detection method based on a sliding mode observer for open-switch faults in modular multilevel converters has been reported in [11].”
MethodJi, B., Pickert, V., Cao, W., & Zahawi, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2251358 · Cited by 329 · cited 1×
“The in situ diagnostic and prognostic technology to monitor the health condition of insulated gate bipolar transistors (IGBTs) used in electric vehicle with a focus on the IGBTs’ solder layer fatigue and wire-bond-related failure have been presented in [5] and [6].”
BackgroundOpen-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Sleszynski, W., Nieznanski, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300 · cited 1×
“Signal-based approaches to detect open-switch fault are classified as current-based [15], [16] and voltage-based [17], [18].”
BackgroundFault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906994 · Cited by 284 · cited 2×
“An artificial intelligence-based approach to detect the faults of cascaded H-bridge converter was presented in [21].”
MethodJung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
Fuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270 · cited 1×
“Surveys regarding open-switch fault diagnosis methods for the three-phase PWM inverters have been reported in [25] and [26].”
Background
Cited by
A Review of Fault Detection and Diagnosis for the Traction System in High-Speed Trains
Chen, H., & Jiang, B. (2020) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2019.2897583 · Cited by 413
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“integral observers are employed [30], [33]–[36].”
BackgroundOpen-Circuit IGBT Fault Detection and Location Isolation for Cascaded Multilevel Converters
Lamb, J., & Mirafzal, B. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674629 · Cited by 170
“, artificial neural networks and genetic algorithms [13], can also be used to identify faulty switches in multilevel converters by utilizing significant computational effort [6], [16], as well as application specific data or expert knowledge for training.”
BackgroundInfluentialGe, X., Pu, J., Gou, B., & Liu, Y.-C. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2691804 · Cited by 158
“Condition monitoring and fault diagnosis for power devices are highly desirable and necessary to ensure safety and reducemaintenance costs in electric railway traction [5].”
BackgroundMethodInfluentialSelf-citationWu, F., & Zhao, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2587339 · Cited by 82
“In [31], mixed logical dynamic model and generated residual are used for open-circuit fault diagnosis in a single-phase rectifier.”
MethodBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Metadata
- Authors
- Gou, B., Ge, X., Wang, S., Feng, X., Kuo, J. B., & Habetler, T. G.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-05
- Volume
- 31
- Issue
- 5
- Pages
- 3816-3826
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2205067742
- Cited by
- 191
- References
- 26
- FWCI
- 11.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.