Steady-State Modeling of Modular Multilevel Converter Under Unbalanced Grid Conditions
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
This paper presents a steady-state model of MMC for the second-order phase voltage ripple prediction under unbalanced conditions, taking the impact of negative-sequence current control into account. From the steady-state model, a circular relationship is found among current and voltage quantities, which can be used to evaluate the magnitudes and initial phase angles of different circulating current components. Moreover, in order to calculate the circulating current in a point-to-point MMC-based HVdc system under unbalanced grid conditions, the derivation of equivalent dc impedance of an MMC is discussed as well. According to the dc impedance model, an MMC inverter can be represented as a series connected R-L-C branch, with its equivalent resistance and capacitance directly related to the circulating current control parameters. Experimental results from a scaled-down three-phase MMC system under an emulated single-line-to-ground fault are provided to support the theoretical analysis and derived model. This new models provides an insight into the impact of different control schemes on the fault characteristics and improves the understanding of the operation of MMC under unbalanced conditions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Grainger, J. J., & Stevenson, W. D. (1994) · Cited by 2,754
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387 · cited 1×
“Moreover, the steady-state model can help the circulating current controller design and maximum modulation index calculation, using the same methodology discussed in [40] and [41] for balanced conditions.”
MethodDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188
Classification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172 · cited 1×
“, modular multilevel converters (MMCs) have become a promising technology for high-voltage direct-current (HVdc) transmission systems to transmit power from far away locations, like offshore wind farms, to main ac power grids [1]–[3].”
BackgroundRodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., & Blaabjerg, F. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2042420 · Cited by 1,112 · cited 1×
“To achieve an accurate synchronization with the grid voltage, the positive-sequence voltage is extracted with methods proposed in [24] and used as the input of a phaselocked loop (PLL).”
MethodDual current control scheme for PWM converter under unbalanced input voltage conditions
Song, H.-S., & Nam, K. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793344 · Cited by 930 · cited 1×
“4 shows the diagram of the classic dual-current control, which consists of positive- and negative-sequence current control [22], [23].”
BackgroundOn dynamics and voltage control of the Modular Multilevel Converter
Antonopoulos, A., Ängquist, L., & Nee, H. (2009) · European Conference on Power Electronics and Applications · Cited by 831
New transformerless, scalable Modular Multilevel Converters for HVDC-transmission
Allebrod, S., Hamerski, R., & Marquardt, R. (2008) · 2008 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2008.4591920 · Cited by 785
Grainger, J. J., & Stevenson, W. D. (1994) · CERN Document Server (European Organization for Nuclear Research) · Cited by 747
Dynamic Analysis of Modular Multilevel Converters
Harnefors, L., Antonopoulos, A., Norrga, S., Angquist, L., & Nee, H.-P. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194974 · Cited by 623 · cited 2×
“According to [38] and [39], v cu and v k cl can be calculated as”
BackgroundMethod
Research works printed but not linked: 6
- godoy, 0, Tutorial on single-pole tripping and reclosing, Proc 35th Annu Western Protective Relay Conf, 1
- serna reyna, 0, Transmission line single-pole tripping: field experience of the western transmission area of Mexico, Proc 35th Annu Western Protective Relay Conf, 1
- ma, 2014, System scheme of Zhoushan multi-terminal VSC-HVDC project, Electric Power Construction, 35, 1
- saad, 0, Commissioning of the France Spain HVDC VSC control system replicas, Proc CIGRE-IEC Colloquium, 1
- tu, 2012, Reduced switching-frequency modulation and circulating current suppression for modular multilevel converter, IEEE Trans Power Del, 26, 2009
- ängquist, 0, On dynamics and voltage control of the modular multilevel converter, Proc Eur Conf Power Electron Appl, 1
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
Sinha, A., Jana, K. C., & Das, M. K. (2018) · Solar Energy · doi:10.1016/j.solener.2018.06.001 · Cited by 135
Zhu, J., Hu, J., Wang, S., & Wan, M. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.2976776 · Cited by 63
A Comprehensive Review on Multilevel Inverters for Grid-Tied System Applications
Salem, M., Richelli, A., Yahya, K. A., Hamidi, M. N., Ang, T.-Z., & Alhamrouni, I. (2022) · Energies · doi:10.3390/en15176315 · Cited by 63
Wang, Z., Chinthavali, M., Campbell, S. L., Wu, T., & Ozpineci, B. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2938471 · Cited by 55
Self-citationGuo, C., Yang, J., & Zhao, C. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2831193 · Cited by 53
“The analytical expressions for steadystate circulating current and capacitor voltage quantities for the MMC system were presented in [15] under the unbalanced grid”
MethodLiu, Z., & Zhao, J. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3006234 · Cited by 44
“Then together with (2) and (3), the average capacitor currents in upper and lower arms of phase-j are obtained as (4) according to [12] { icpj = Spj · ipj = λp0 + λp1 + λp2 icnj = Snj · inj = λn0 + λn1 + λn2 (4)”
MethodWang, S., Dragičević, T., Gao, Y., Chaudhary, S. K., & Teodorescu, R. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2982109 · Cited by 45
Dong, Y., Yang, H., Li, W., & He, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2833019 · Cited by 39
Analysis and Assessment of Modular Multilevel Converter Internal Control Schemes
Wang, S., Adam, G. P., Massoud, A. M., Holliday, D., & Williams, B. W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2899794 · Cited by 41
“first harmonics, respectively [51], [78]; therefore, a number of”
BackgroundLi, G., Liang, J., Ugalde‐Loo, C. E., Ma, F., Liang, H., & Song, Z. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.2974413 · Cited by 36
“Since a delta/star transformer connection with a grid-side neutral grounding is widely used in HVDC systems [28]-[29], this type of transformer is adopted in this paper.”
MethodStepanov, A., Saad, H., Karaagac, U., & Mahseredjian, J. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2872883 · Cited by 32
“Control signals in steady-state analysis of MMCs are considered in [16]–[21], but the authors consider open-loop control (i.”
BackgroundAn MMC Circulating Current Suppressing Controller Based on Bridge Arm Common-Mode Voltage
Yang, Z., Song, P., Song, J. C., Wang, X., & Li, X. S. (2020) · IEEE Access · doi:10.1109/access.2020.3031307 · Cited by 27
Small-Signal Model and Dynamics of MMC-HVDC Grid Under Unbalanced Grid Conditions
Hao, Q., Li, Z., Yue, C., Gao, F., & Wang, S. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3035650 · Cited by 26
Modeling and Harmonic Stability of MMC-HVDC With Passive Circulating Current Filters
Zhang, B., & Nademi, H. (2020) · IEEE Access · doi:10.1109/access.2020.3009331 · Cited by 22
Liu, Z., Miao, S., Fan, Z., Chao, K., & Liu, Y. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2018.08.037 · Cited by 18
Optimal Current Reference Calculation for MMCs Considering Converter Limitations
Spier, D. W., Prieto‐Araujo, E., López‐Mestre, J., & Gomis‐Bellmunt, O. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3020420 · Cited by 18
Lin, L., He, J., & Xu, C. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2019.000213 · Cited by 17
Xu, J., Weicheng, D., Li, G., Zhao, C., & Liu, C. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3118690 · Cited by 17
“The AC reference voltages controller includes positive-and negative-sequence closed loop controllers which are typical control in MMC [27] . i d_refp and i q_refp are the references of positive-sequence dq -axis currents, which generate the positive-sequence AC reference voltage e j_refp (j= a , b…”
Zhang, J., Li, B., Chen, F., Li, B., Ji, X., & Xiao, F. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.109855 · Cited by 16
The Predictive Closed-Loop Averaging Control of MMC Phase-Unit Losses Under Unbalanced Conditions
Xu, J., Yu, Y., & Zhao, C. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2868772 · Cited by 14
Block Diagonal Dominance-Based Model Reduction Method Applied to MMC Asymmetric Stability Analysis
Zong, H., Zhang, C., Lyu, J., Cai, X., & Molinas, M. (2021) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2021.3054925 · Cited by 14
Li, Y., Guo, P., Hu, J., Xu, Q., & Jia, Y. (2023) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2023.109589 · Cited by 12
Self-citationSong, S., Liu, J., Du, S., Chen, X., Liu, H., & Lin, W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2974585 · Cited by 13
Adaptive Modular Multilevel Converter Model for Electromagnetic Transient Simulations
Stepanov, A., Mahseredjian, J., Karaagac, U., & Saad, H. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.2993502 · Cited by 13
A novel sub-module topology for MMC against DC side short-circuit faults
Xue, Y., Yang, X., Zheng, T. Q., Chen, B., & Li, Y. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096725 · Cited by 11
“Compared with traditional voltage source converter (VSC), modular multilevel converter (MMC) is more competitive since its distinct features such as high voltage level, low switching frequency, and modular design [1-4].”
BackgroundSelf-citationVelasco, M., Martí, P., Camacho, A., Rey, J. M., Miret, J., & Castilla, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2938906 · Cited by 10
Practical Submodule Capacitor Sizing for Modular Multilevel Converter Considering Grid Faults
Yin, Z., Qiu, H., Yang, Y., Tang, Y. K., & Wang, H. (2020) · Applied Sciences · doi:10.3390/app10103550 · Cited by 11
“To solve this problem, the control method of the MMC under unbalanced grid conditions is discussed in [21] and the literature [22] gives the mathematical model of the SM voltage, considering the positiveand negative-sequence of grid voltages and the MMC arm currents.”
MethodSmall-Signal Stability of MMC Grid-Tied System Under Two Typical Unbalanced Grid Conditions
Zhu, J., Hu, J., Li, Y., Ma, S., & Wang, T. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3176596 · Cited by 8
Self-citationIndependent positive- and negative-sequence control for MMC-SAPF with unbalanced PCC voltage
Li, C., Dai, K., Lin, D., Xu, C., Chen, C., & Dai, Z. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096016 · Cited by 7
“9 is also indispensable to guarantee normal operation of MMC-SAPF[10], [12].”
BackgroundWu, T., Huang, C., Chou, T.-C., & Sun, K. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2952830 · Cited by 7
“For high-voltage applications, such as active power filter (APF) [1] and shunt active-power-filter (SAPF) [2], MMC static synchronous compensator (MMC-STATCOM) [3], [4], grid interconnection [5], [6], and green and low-carbon energy applications [7], they need only to cascade additional modules to each arm.”
BackgroundLi, D., Huang, X., Nie, C., Chen, R., Lin, M., Wang, F., & Tolbert, L. M. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3491615 · Cited by 6
“According to [6], [16], and [21], if no unbalance control is applied, the average switching function of the upper and lower arms are where M is the modulation index.”
Self-citationDevelopment of a Flexible Modular Multilevel Converter Test-Bed
Zhang, S., Wang, S., Praisuwanna, N., Kong, L., Li, Y., Martin, R. B., Wang, F., & Tolbert, L. M. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557403 · Cited by 6
Self-citationThakur, S. S., Odavić, M., & Zhu, Z. Q. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3104788 · Cited by 7
Wang, S., Dragičević, T., & Teodorescu, R. (2020) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg48541.2020.9244470 · Cited by 6
Tian, R., Wu, X., Jing, L., Xu, W., Sun, Z., & Cao, W. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3323503 · Cited by 5
“…full-bridge modular multilevel converter (FB-MMC) can directly convert three-phase ac voltage to single-phase ac voltage with high voltage and excellent power quality [10], [11] without complex ac-dc-ac conversion, which is perfectly suitable for electrified railway power supply system [12], [13].”
BackgroundA Generic Steady-State Analysis Model for Three-Phase Three-Wire Modular Multilevel Converter
Chen, X. (2023) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2023.00020 · Cited by 5
HVDC grids with heterogeneous configuration stations under DC asymmetrical operation
Serrano-Sillero, J., Moreno, M. Á., & Morales, A. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.05.053 · Cited by 7
Steady-State Analysis of the Modular Multilevel Converter
Spier, D. W., Mestre, J. L., Prieto‐Araujo, E., & Gomis‐Bellmunt, O. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8927796 · Cited by 5
“Another approach to describe the steady-state behavior of the MMC was introduced by [14].”
BackgroundHao, Q., Li, D., Li, B., & Wang, S. (2020) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2019.1450 · Cited by 4
Zhao, C., Gao, F., Li, Z., Wang, P., & Li, Y. (2020) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2020.3014657 · Cited by 5
Self-citationSmall-signal stability analysis of the asymmetrical DC operation in HVDC networks
Serrano-Sillero, J., & Moreno, M. Á. (2022) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.108942 · Cited by 4
Soft Single-Pole Reclosing Control for MMC-Connected AC Transmission Lines
Tong, N., Li, J., Li, G., Huang, W., Cao, R., & Wang, Y. (2024) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2024.3447084 · Cited by 3
“According to reference [7], the well-adopted dual-vector control strategy works well to suppress the negative-sequence current and reduce the unbalance.”
BackgroundResearch on the fault characteristics of HVDC with wind farm
Erman, B., Xu, H., Kang, C., Liu, J., Wang, Z., & Fan, S. (2017) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei2.2017.8245369 · Cited by 3
Self-citationSmall-Signal Stability of MMC Grid-Tied System under Two Typical Unbalanced Grid Conditions
Zhu, J., Hu, J., Li, Y., Ma, S., & Wang, T. (2021) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec50170.2021.9510933 · Cited by 3
Self-citationZhou, Y., Qin, L., Yang, S., Wang, Q., & Liu, K. (2023) · IET Power Electronics · doi:10.1049/pel2.12606 · Cited by 3
MPC based on balanced positive-sequence extraction strategy for grid-tied converter control
Kanaan, A., Sebaaly, F., & Kanaan, H. Y. (2017) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2017.8001501 · Cited by 3
“Recently, multilevel inverters topology is one of the most trending technology in power electronics systems for energy generation applications [1-3].”
BackgroundA Control Method of DC Capacitor Voltage in MMC for HVDC System using Negative Sequence Current
Jaffar, H. A. B., Rahman, A. A. B. A., & Kakigano, H. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8502769 · Cited by 3
An Accurate Accelerated Steady-State Model for High-Level Modular Multilevel Converters
Subroto, R. K., Chen, Y., Lian, K. L., Tsai, J. T., & Chu, C. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3082861 · Cited by 3
del Giudice, D., Bizzarri, F., Linaro, D., & Brambilla, A. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.110163 · Cited by 2
Yin, Z., Qiu, H., Yang, Y., Tang, Y. K., & Wang, H. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8912833 · Cited by 2
“In the case of unbalanced grid conditions, the steady-state SM voltage ripples are analyzed in [8], considering the positive- and negative-sequence grid voltages and the MMC arm currents.”
BackgroundThahab, R. T., & Al-Mhana, T. (2020) · International journal of intelligent engineering and systems · doi:10.22266/ijies2020.0831.11 · Cited by 2
“On the other hand, literature [14-18] mainly investigates control methods and/or modeling of arm currents under an asymmetrical grid voltage conditions.”
BackgroundMethodInfluentialA Controllable Distributed Energy Resource Transformer-Based Grounding Scheme for Microgrids
Li, D., Ma, Y., Su, Y., Zhang, C., Zhu, L., Yin, H., Wang, F., & Tolbert, L. M. (2024) · IEEE Open Access Journal of Power and Energy · doi:10.1109/oajpe.2024.3381609 · Cited by 1
“One typical configuration is (cid:49) -Yg, where the Yg connection is located on the MG side [12], [13], [14].”
BackgroundSelf-citationStability modeling of MMC-HVDC transmission system with differential flat control
Feng, Z., & Li, H. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2741/1/012068 · Cited by 1
Chen, Y., Wang, Z., Wen, M., & Yin, X. (2025) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2025.110553 · Cited by 1
Self-citationBack-to-Back Modular Multilevel Converter for drive applications under unbalanced grid conditions
Donoso, F., Espinoza, M., Díaz, M., Letelier, A., & Cárdenas, R. (2018) · European Conference on Power Electronics and Applications · Cited by 1
Panova, E. A., & Nasibullin, A. T. (2018) · International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM) · doi:10.1109/icieam.2018.8728796 · Cited by 1
Vozikis, D., Alsokhiry, F., & Adam, G. P. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107266 · Cited by 1
Nasibullin, A. T., & Panova, E. A. (2021) · International Ural Conference on Electrical Power Engineering (UralCon) · doi:10.1109/uralcon52005.2021.9559522 · Cited by 1
“In a comparative analysis of the data obtained, it was determined that the highest accuracy at a frequency of 50 Hz provided by a sampling step of 50 μs [24-29].”
BackgroundSteady-State Initialization of AC-DC Grids with Complex Controllers for Transient Simulations
Wu, X., Zhao, L., Zhou, B., Hong, C., Su, Y., & Tu, S. (2022) · International Conference on Smart Power & Internet Energy Systems (SPIES) · doi:10.1109/spies55999.2022.10082635 · Cited by 1
Tian, R., Wu, X., Jing, L., Tang, F., & Sun, Z. (2024) · Asia Conference on Power and Electrical Engineering (ACPEE) · doi:10.1109/acpee60788.2024.10532614 · Cited by 1
“Unbalanced grid typically arises from asymmetrical line parameters and asymmetrical faults at grid side [10], [11].”
BackgroundStability Modeling and Parameter Analysis for Flexible DC Power Grids Under Asymmetric Conditions
Li, H., Feng, Z., Fan, X., & Liu, S. (2024) · IEEE Access · doi:10.1109/access.2024.3441603 · Cited by 1
“Asmall-signal model of MMC under asymmetrical conditions was put forward in [20] and [21], taking into account the internal dynamic behavior of MMC, then eigenvalue and participation factor analysis methods were used to obtain key state variables affecting the system stability.”
MethodRua, P. D., & Beerten, J. (2024) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2024.110336 · Cited by 1
Wang, L., Fan, Y., Zhang, D., Ge, M., Zou, X., & Li, J. (2017) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/231/1/012078
“There are a variety of operation modes for the back-to-back flexible DC convertor([7,8,9,10]).”
BackgroundSpier, D. W., Prieto‐Araujo, E., López‐Mestre, J., & Gomis‐Bellmunt, O. (2021) · European Conference on Power Electronics and Applications · doi:10.23919/epe21ecceeurope50061.2021.9570655
Interaction Analysis of Current Control Loops in MMC Under Asymmetrical Grid Faults
Che, J., Huang, M., Zha, X., Sheng, J., & Fu, X. (2021) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce47101.2021.9595492
An Improved Valve-Side Fault-Riding-Through Control Strategy for Hybrid MMC
Zhang, J., & Li, P. (2022) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-himeji2022-ecce53331.2022.9806869
“Exploring Handleable Range By Arm Energy Analysis Considering the arm energy balance, after calculating the instantaneous expression of arm power [14], (11) can get by making the dc component 0:”
BackgroundWang, D., Jiang, X., Li, M., Zhang, K., Jiao, J., & Dong, Q. (2023) · IEEE International Conference on Power, Intelligent Computing and Systems (ICPICS) · doi:10.1109/icpics58376.2023.10235578
“In engineering, the MMC may suffer from ac grid asymmetrical faults [3], such as grid-side single-phase grounding fault.”
BackgroundInitialization of modular multilevel converters based on the shooting method
Giudice, D. D., Bizzarri, F., Linaro, D., & Brambilla, A. (2023) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs58634.2023.10382872
“The MMC steady-state operating conditions were derived in [2]–[4] by assuming that control signals are known and given by the fundamental frequency only.”
BackgroundZhao, M., Ping, D., Wen, J., Ma, L., & Weiwei, M. (2023) · IEEE Sustainable Power and Energy Conference (iSPEC) · doi:10.1109/ispec58282.2023.10403009
“…and negative sequence compensation strategies to suppress voltage fluctuations caused by imbalanced common coupling points [18], etc. Reference [19] established a dynamic model for the VSC-HVDC system under asymmetric operating conditions, modeling the positive and negative sequence main…”
BackgroundFPGA-based Voltage Balancing Control for MMC
Hou, Y., Li, K., Li, L., Fan, D., Sun, K., Huang, Q., Sun, Y., & Zhang, G. (2024) · IEEE Conference on Energy Internet and Energy System Integration (EI2) · doi:10.1109/ei264398.2024.10990559
“The number of single-arm SMs has reached as high as 500 in engineering, which leads to high resource and time consumption for sorting, resulting in the increase in the cost and delay for voltage balancing control link [4-5].”
Hu, J., Fan, F., Li, G., & Lei, M. (2025) · IEEE International Conference on Electrical Energy Conversion Systems and Control (IEECSC) · doi:10.1109/ieecsc64206.2025.11099706
“Reference [7] points out that the asymmetry of AC grid will cause three-phase instantaneous power oscillation at the AC side of MMC, leading to imbalance of the bridge arm capacitor voltages, and simultaneously causing large double line-frequency current and voltage fluctuations on the DC side.”
Time-domain steady-state modeling of a direct AC/AC full-bridge modular multilevel converter
Sun, L., Song, S., Du, Q., & Ma, W. (2026) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2026.111844
Metadata
- Authors
- Shi, X., Wang, Z., Liu, B., Li, Y., Tolbert, L. M., & Wang, F.
- Affiliations
- University of Tennessee at Knoxville (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-09
- Volume
- 32
- Issue
- 9
- Pages
- 7306-7324
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2551352876
- Cited by
- 73
- References
- 32
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 10 · 2023: 8 · 2022: 4 · 2021: 11 · 2020: 15 · 2019: 8 · 2018: 9 · 2017: 5
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- Engineering Research Center Program of the National Science Foundation
- NSF (EEC-1041877)
- CURENT Industry Partnership Program
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Keywords
- modular multilevel converter, steady-state model, unbalanced grid conditions, negative sequence current control, circulating current, HVDC transmission, single-phase grounding fault, fault characteristics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.