Short-Circuit Degradation of 10-kV 10-A SiC MOSFET
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The short-circuit behavior of power devices is highly relevant for converter design and fault protection. In this paper, the degradation during short circuit of a 10-kV 10-A 4H-SiC MOSFET is investigated at 6 kV dc-link voltage. The study aims to present the behavior of the device during short-circuit transients as it sustains increasing short-circuit pulses during its lifetime. As the short-circuit pulse length increases, degradation of the device can be observed in periodically performed characterizations. The initial degradation seems to be associated with the channel region, and continuous stressing leads to an overall increase in device on-state resistance at the end of the degradation study. Thermal simulation shows that the surface aluminum metallization reached its melting temperature and the top part of the device reaches temperatures above the rated junction temperature. Scanning electron microscope investigation shows aluminum reconstruction and cavities at the contact interface between the aluminum surface metalization and source contacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reliability and performance limitations in SiC power devices
Singh, R. (2006) · Microelectronics Reliability · doi:10.1016/j.microrel.2005.10.013 · Cited by 284
10 kV/120 A SiC DMOSFET half H-bridge power modules for 1 MVA solid state power substation
Grider, D., Das, M., Agarwal, A., Palmour, J., Leslie, S., Ostop, J., Raju, R., Schutten, M., & Hefner, A. (2011) · 2011 IEEE Electric Ship Technologies Symposium · doi:10.1109/ests.2011.5770855 · Cited by 115 · cited 1×
“The technology has made it possible for unipolar devices with ratings in excess of 10 kV to be designed and manufactured [3]–[5].”
BackgroundSelf-citationRumyantsev, S. L., Shur, M. S., Levinshtein, M. E., Ivanov, P. A., Palmour, J. W., Agarwal, A. K., Hull, B. A., & Ryu, S.-H. (2009) · Semiconductor Science and Technology · doi:10.1088/0268-1242/24/7/075011 · Cited by 66
Self-citation
Cited by
Review and analysis of SiC MOSFETs’ ruggedness and reliability
Wang, J., & Jiang, X. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2019.0587 · Cited by 221
Power Electronics Reliability: State of the Art and Outlook
Wang, H., & Blaabjerg, F. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3037161 · Cited by 218
“A case study of a 10 kV/10 A SiC MOSFET tested under 6 kV is presented in [30].”
MethodOverview of high voltage sic power semiconductor devices: development and application
Ji, S., Zhang, Z., & Wang, F. (2017) · CES Transactions on Electrical Machines and Systems · doi:10.23919/tems.2017.8086104 · Cited by 208
1200-V SiC MOSFET Short-Circuit Ruggedness Evaluation and Methods to Improve Withstand Time
Xing, D., Hu, B., Kang, M., Zhang, Y., Nayak, S., Wang, J., & Agarwal, A. K. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3144995 · Cited by 33
“SiC devices is discussed [7], [18]–[21].”
A Critical Review on Reliability and Short Circuit Robustness of Silicon Carbide Power MOSFETs
Sreejith, S., Ajayan, J., Devasenapati, S. B., Sivasankari, B., & Tayal, S. (2023) · Silicon · doi:10.1007/s12633-022-02039-1 · Cited by 11
Metadata
- Authors
- Eni, E.-P., Bęczkowski, S., Munk-Nielsen, S., Kerekes, T., Teodorescu, R., Juluri, R. R., Julsgaard, B., VanBrunt, E., Hull, B., Sabri, S., Grider, D., & Uhrenfeldt, C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2017-12
- Volume
- 32
- Issue
- 12
- Pages
- 9342-9354
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2580309625
- Cited by
- 75
- References
- 3
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.