PWM-VSI Fault Diagnosis for a PMSM Drive Based on the Fuzzy Logic Approach
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
For the purpose of increasing the reliability in a hostile environment, techniques of fault diagnosis have been reported for a three-phase voltage-source inverter (VSI). Based on the average current Park's vector method, this paper proposes a fuzzy-based fault diagnosis method for the VSI in the three-phase permanent-magnet synchronous motor drive. By utilizing the phase current information, the fault symptom variables are calculated by using the average current Park's vector method. The fuzzy logic approach is applied to process the fault symptom variables and obtain the faulty information of power switches. Compared with other fuzzy logic methods, the fuzzy logic design, fuzzy inputs, and fuzzy rules are different. The proposed fault diagnosis method can detect and locate not only the single or multiple open-circuit faults, but also the intermittent faults in power switches, which can improve the reliability of the motor drive system. The effectiveness of the proposed method is validated by both simulation and experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey of design methods for failure detection in dynamic systems
Willsky, A. S. (1976) · Automatica · doi:10.1016/0005-1098(76)90041-8 · Cited by 2,153 · cited 1×
“In the early papers, the key concepts of analytical redundancy for model-based fault detection and diagnosis were proposed in 1976 [13].”
BackgroundA survey of design methods for failure detection in dynamic systems
(1977) · Microelectronics Reliability · doi:10.1016/0026-2714(77)90326-2 · Cited by 1,421
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Cruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
A Robust Observer-Based Sensor Fault-Tolerant Control for PMSM in Electric Vehicles
Kommuri, S. K., Defoort, M., Karimi, H. R., & Veluvolu, K. C. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2590993 · Cited by 408 · cited 1×
“permanent-magnet synchronous motors (PMSMs) have been widely used in electric vehicles, aerospace, medical, and military applications [1]–[6].”
BackgroundFault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Fault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361 · cited 1×
“multilevel converters (MMCs) based on a sliding-mode observer and a switching model of a half-bridge is proposed in [22].”
BackgroundLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329 · cited 1×
“In [26], a fault diagnosis”
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304 · cited 1×
“In [14], an approach based on knowledge models to detect and isolate faults in a PWM-VSI is proposed, which is implemented by analyzing the current-vector trajectory and the instantaneous frequency in the faulty mode.”
MethodA New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298 · cited 1×
“faults in the PWM-VSI, the whole PMSM drive system will not operate normally [9]–[11].”
Background
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Diagnosis of Open-Switch and Current Sensor Faults in PMSM Drives Through Stator Current Analysis
Khojet El Khil, S., Jlassi, I., Marques Cardoso, A. J., Estima, J. O., & Mrabet-Bellaaj, N. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2930592 · Cited by 147
“Hence, this approach is usually associated with other algorithms, such as fuzzy logic approach [29], [30] or the motor currents slope variation in the α–β frame [31], to aim both single and multiple inverter fault diagnosis purpose.”
MethodBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
A hybrid diagnosis method for inverter open-circuit faults in PMSM drives
Zhang, Z., Luo, G., Zhang, Z., & Tao, X. (2020) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2020.00023 · Cited by 39
“In [18], normalized current-vector is introduced as diagnosis variable, and the diagnosis results are determined by fuzzy inference.”
MethodNaseri, F., Schaltz, E., Lu, K., & Farjah, E. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2019.1498 · Cited by 37
Metadata
- Authors
- Yan, H., Xu, Y., Cai, F., Zhang, H., Zhao, W., & Gerada, C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2019-01
- Volume
- 34
- Issue
- 1
- Pages
- 759-768
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2792175060
- Cited by
- 216
- References
- 22
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.