High-Efficiency SiC-Based Isolated Three-Port DC/DC Converters for Hybrid Charging Stations
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
This article proposes a novel isolated three-port dc/dc converter based on a series resonant converter and a dual active bridge (DAB) converter for electric-vehicle charging stations with fast and slow charging functions. With this three-port structure, the proposed converter has fewer components, which results in lower system cost and volume compared with separate charger systems. A simple control method using phase-shift and frequency modulations was developed to control the output power of the fast and slow charging ports simultaneously. An optimal phase-shift angle was also derived to minimize the transformer current for when only the DAB converter is operated for slow charging. To verify the converter operation, a 5-kW SiC-based prototype with a power density of 2.74 kW/dm3was built and tested with an input voltage of 600 V. A high-efficiency performance over a wide output voltage range has been achieved, and the peak efficiency is 98.2% at the rated conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yilmaz, M., & Krein, P. T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212917 · Cited by 3,118 · cited 1×
“However, the power flow of fast chargers, where the power capacity is higher than 50 kW, is usually unidirectional from the power grid to EV batteries [23], [24].”
BackgroundA comparison of half-bridge resonant converter topologies
Steigerwald, R. L. (1988) · IEEE Transactions on Power Electronics · doi:10.1109/63.4347 · Cited by 1,972 · cited 1×
“port 2 is designed for fast charging and comprises a resonant tank and a full-bridge diode rectifier [30].”
BackgroundZhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932 · cited 1×
“When the duty cycle of the primary voltage is adjusted to reduce the turnOFF current, the operation mode of DAB port is equivalent to the EPS operation mode, which has been analyzed comprehensively in the literature [44]–[46].”
MethodAn Isolated Three-Port Bidirectional DC-DC Converter With Decoupled Power Flow Management
Zhao, C., Round, S. D., & Kolar, J. W. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2002056 · Cited by 900 · cited 2×
“For the triple DAB converter [8], [9] and the resonant TPC [11], high efficiency of 97% can be achieved with SiC devices.”
BackgroundMethodExtreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898 · cited 1×
“converter, and DAB converter [25], [26].”
Global Trends in High-Power On-Board Chargers for Electric Vehicles
Khaligh, A., & D'Antonio, M. (2019) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2019.2897050 · Cited by 652 · cited 1×
“However, the power flow of fast chargers, where the power capacity is higher than 50 kW, is usually unidirectional from the power grid to EV batteries [23], [24].”
BackgroundClosed Form Solution for Minimum Conduction Loss Modulation of DAB Converters
Krismer, F., & Kolar, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2157976 · Cited by 635 · cited 2×
“At rated current operation, the SPS modulation has been proved to be effective for the DAB converter [38], [42], Fig.”
BackgroundHou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553 · cited 1×
“There are various control strategies for DAB converters, such as single-phase-shift (SPS), extended-phase-shift (EPS), dual-phase-shift, and triple-phase-shift control [38]–[41].”
BackgroundFalcones, S., Ayyanar, R., & Mao, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215965 · Cited by 501 · cited 1×
“introduced with phase-shift modulation [10].”
Cited by
Safayatullah, M., Elrais, M. T., Ghosh, S., Rezaii, R., & Batarseh, I. (2022) · IEEE Access · doi:10.1109/access.2022.3166935 · Cited by 615
“[189] 3 Ports: DC source, (after AC-DC rectifier), EV, EV/Energy Storage Triple Active Bridge, Dual Active Bridge, Series Resonant 5 grid→EV-1, grid→EV-2/ES, ES→grid, grid→EV-1 & EV2/ES (Simultaneously) 98.”
BackgroundReview of Dual-Active-Bridge Converters With Topological Modifications
Li, L., Xu, G., Sha, D., Liu, Y., Sun, Y., & Su, M. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3258418 · Cited by 166
“Multiwinding fully isolated DAB converters with different bridge cells are discussed in [197], [198], [199], [200], [201], and [202].”
Background
Metadata
- Authors
- Dao, N. D., Lee, D.-C., & Phan, Q. D.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2020-10
- Volume
- 35
- Issue
- 10
- Pages
- 10455-10465
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W3007583211
- Cited by
- 174
- References
- 41
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.