Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index; 2 of the 31 sources its claims cite were checked for support.
Abstract
This article presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.
Overview
CoChat Summary
TL;DR
This paper presents a three-stage optimal design methodology for a 200-kW, 15-kHz medium-frequency transformer (MFT) using FINEMET® FT-3TL nanocrystalline cores and a parallel-concentric winding structure. The prototype achieves >19.23 kW/L power density, PD-free operation up to 5.3 kV RMS/7.5 kV peak, and 99.842% MFT efficiency at 200 kW in a 200-kW DAB converter.
Key findings
- The parallel-concentric winding structure gave the lowest measured leakage inductance among compared structures: 2.6 µH and a leakage-to-magnetizing inductance ratio of 0.023%; the final prototype reported 5.36 µH / 21.67 mH (0.0247%).
- The optimized MFT prototype achieved a power density higher than 19.23 kW/L, with insulation tested at 12 kV AC peak and partial discharge (PD) testing at 7.5 kV AC peak; measured PDIV was about 5.3 kV RMS/7.5 kV peak, with PD smaller than 50 pC and PD rate much less than 1 pulse/cycle.
- In the 200-kW DAB converter, the peak DAB efficiency was 99.53% at 50 kW and 98.85% at 200 kW; the MFT peak efficiency was 99.844% at around 180 kW and 99.842% at 200 kW.
- At 200 kW, measured maximum core surface temperature rise was about 25 °C and winding temperature rise was 23 °C; the paper states MFT core temperature rise at 200 kW is lower than 30 °C.
Methods
- Design and optimization methodology with three stages: predesign, preliminary design, and optimal design; it selects magnetic core material/dimensions, Litz wire, insulation materials, and winding structure, then sweeps free parameters such as switching frequency, turns number, and bobbin dimensions.
- Core loss evaluation compared OSE, MSE, GSE, and IGSE models, with IGSE selected; winding loss used Dowell’s model and FFT-based harmonic summation; thermal design used a detailed steady-state thermal network and fluid/thermal simulation.
- Experimental verification used a 200-kW DAB converter with 1700-V SiC MOSFET modules, 1300-V input, and 15-kHz operation; PD testing was based on IEC 60270, and DAB efficiency was measured with a HIOKI PW6001 power analyzer, while MFT efficiency was calculated from experimental core and winding loss information.
Limitations
- The paper does not include an explicit limitations section.
- Evident from the text: although high-frequency bipolar PWM insulation/PD testing is claimed as first applied in MFT design and test, the developed MFT’s PD detection was performed with a 60-Hz sine wave because no well-established standard method exists for reliable PD measurement under PWM excitations.
- Evident from the text: MFT efficiency is reported as calculation efficiency based on experimental core and winding losses, rather than as a directly measured transformer efficiency.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 Valid · 7 Not valid · 11 Not checked · 79 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The selected working frequency of the MFT is 15kHz which is based on the efficiency and dimension optimization of the whole DAB converter system[20-21].”
What the sources say
- Partly supportedcites [20] [20] W. Xu et al., "Hardware Design and Demonstration of a 100kW, 99% Efficiency Dual Active Half Bridge Converter Based on 1700V SiC Power MOSFET," 2020 IEEE Applied Power Electronics Conference and Exposition (APEC), New Orleans, LA, USA, 2020, pp. 1367-1373, doi: 10.1109/APEC39645.2020.9124401. - sourceExperimental — accuracy not yet measured
Table IV lists 15–50 kHz as the converter’s switching-frequency range, so 15 kHz is included. But the paper describes a variable-frequency converter (Conclusions) and does not say that 15 kHz was selected through an efficiency-and-dimension optimization of the whole system. (LLM, conf=0.85)
- Partly supportedcites [21] [21] W. Xu, R. y. Yu, Z. Guo and A. Q. Huang, "Design of 1500V/200kW 99.6% Efficiency Dual Active Bridge Converters Based on 1700V SiC Power MOSFET Module," 2020 IEEE Energy Conversion Congress and Exposition (ECCE), Detroit, MI, USA, 2020, pp. 6000-6007, doi: 10.1109/ECCE44975.2020.9235903. - sourceExperimental — accuracy not yet measured
The Experiment Results section (page not available in our copy) states that the DAB converter’s switching frequency was fixed at 15 kHz. It does not say that 15 kHz was selected through efficiency-and-dimension optimization of the whole converter, or explicitly identify it as an optimized MFT frequency. (LLM, conf=0.87)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The MFT efficiency is 99.842%, and the temperature rise is lower than 30 °C at 200 kW.”
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“For the parallel-concentric winding structure, the inner layer winding always has higher temperature because the inner layer is surrounded by outer layer winding as an external heat source.”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L.”
- Also stated in: § I. INTRODUCTION · p. 2 · plain
“At this power level, the calculated power density is 19.23 kW/L.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § I. INTRODUCTION · p. 2 · plain
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Besides, the parallel-concentric winding structure also improves the window area utilization factor.”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
46 more claims
Create a free account to see all 98 claims and to verify the 1 reference still open.
- Probably not a substantial claim. 26
- It may state two separate claims as one. 30
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Separate winding structure may suffer from higher leakage inductance due to lower magnetic coupling as compared to concentric or interleaved winding structures [4]; the separate structure however exhibits the best interwinding insulation due to natural separation between the primary and secondary sides, often aided by a small air gap.”
From The Effects of PWM With High dv/dt on Partial Discharge and Lifetime of Medium-Frequency Transformer for Medium-Voltage (MV) Solid State Transformer Applications (2023) · cites this paper as [4]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Guo et al. developed a 200-kW, 15-kHz dual active bridge SST MF transformer in [4] with PD characterization up to 7.5 kV peak.”
The cited source says what the claim attributes to it.
In the citing paper
“The PD test is performed at 60 Hz sine ac voltage bearing different properties compared to PWM voltage.”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ I. INTRODUCTION · p. 1
“These designs have power rating exceeding 50 kW”
§ I. INTRODUCTION · p. 2
“| CUT 2016 [11] | 50 | 5”
Citations
Cites
Effects of eddy currents in transformer windings
Dowell, P. L. (1966) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1966.0236 · Cited by 1,438
Transformer and Inductor Design Handbook
McLyman, C. W. T. (2004) · CRC Press eBooks · doi:10.1201/9780203913598 · Cited by 1,369
Venkatachalam, K., Sullivan, C. R., Abdallah, T., & Tacca, H. (2003) · 2002 IEEE Workshop on Computers in Power Electronics, 2002. Proceedings. · doi:10.1109/cipe.2002.1196712 · Cited by 1,145 · cited 3×
“8 presents the core loss estimation results using OSE, MSE, GSE, and IGSE methods.”
MethodCalculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. A. A. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.936396 · Cited by 704
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642
Self-citationImproved calculation of core loss with nonsinusoidal waveforms
Li, J., Abdallah, T., & Sullivan, C. R. (2002) · Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248) · doi:10.1109/ias.2001.955931 · Cited by 531
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478 · cited 3×
“ABB [8], [13], [14] presents the PD test for their MFTs at 38, 35, and 30 kV to prove the design, but no detailed optimal design for electric field distribution under bipolar PWM excitation is discussed.”
BackgroundKrismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470
Calculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.806023 · Cited by 409
Optimizing the AC resistance of multilayer transformer windings with arbitrary current waveforms
Hurley, W. G., Gath, E., & Breslin, J. G. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.838110 · Cited by 368
Research works printed but not linked: 3
- 10.1109/ICPE · doi:10.1109/icpe
- [42] IEC 60270:2000: High-voltage test techniques - Partial discharge measurements. <!-- image --> <!-- image --> Zhicheng Guo (S'20) was born in Suzhou, China. He received his B.Sc. degree from Southeast University, Nanjing in 2013, and M.S. from National Tsing Hua University, Hsinchu in 2016. He is currently pursuing the Ph.D. degree with the Semiconductor Power Electronics Center, the University of Texas at Austin, Austin, TX, USA. His research interests include the high-power magnetic design, power module packaging. Ruiyang Yu (S'08 -M'13)received the B.E. degree in electrical engineering from Shandong University, Jinan, China, in 2007, and the M.S. and Ph.D. degrees in power electronics from The University of Hong Kong, Hong Kong, in 2008 and 2013, respectively. He was a Post-Doctoral Research Fellow from 2013 to 2017 and an instructor in 2016 with North Carolina State University, Raleigh, NC, USA. He is currently a Research Associate with The University of Texas at Austin, Austin, TX, USA. His research interests include high-frequency and high-power-density power converter design, megawatt power converter design, magnetic components and power converter control. <!-- image --> Wei Xu (S'20) received his B.S and M.S. degree in electrical engineering from Anhui University of technology and Nanjing University of Aeronautics and Astronautics in 2011 and 2014, respectively. He was a senior hardware engineer from 2014 to 2018 with the High-Power Research Team (HPRT), DELTA Electronics, Shanghai, China. He is currently a PhD student at The University of Texas at Austin, Texas, USA. His research interests include high power, high frequency and high- density power converters, magnetic component designs, and power converter control. <!-- image --> <!-- image --> Xianyong Feng (M'12) received a Ph.D. degree in electric power engineering from the Department of Electrical and Computer Engineering at Texas A&M University, College Station, TX, USA, in May 2012. He is currently with the Center for Electromechanics at the University of Texas at Austin, TX. Previously, he worked at ABB, Raleigh, NC, and ExxonMobil, Houston, TX. His research interests include the areas of microgrids, shipboard power systems, and dc power system protection. Alex Q. Huang (S'91 -M'94 -SM'96 -F'05) was bor n in Zunyi, Guizhou, China. He received his B.Sc. degree from Zhejiang University, China in 1983 and his M.Sc. degree from Chengdu Institute of Radio Engineering, China in 1986, both in electrical engineering. He received his Ph.D. from Cambridge University, UK in 1992. From 1992 to 1994, he was a research fellow at Magdalene College, Cambridge. From 1994 to 2004, he was a professor at the Bradley Department of Electrical and Computer Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia. From 2004 to 2017, he was the Progress Energy Distinguished Professor of Electrical and Computer Engineering at NC State University where he established and led the NSF FREEDM Systems Center. Since 2017, he has become the Dula D. Cockrell Centennial Chair in Engineering at University of Texas at Austin. Since 1983, he has been involved in the development of modern power semiconductor devices and power integrated circuits. He fabricated the first IGBT power device in China in 1985. He is the inventor and key developer of the emitter turn-off (ETO) thyristor. He developed the concept of Energy Internet and the smart transformer based Energy Router technology. His current research interests are power electronics, power management microsystems and power semiconductor devices. He has mentored and graduated more than 80 Ph.D. and master students, and has published more than 500 papers in international conferences and journals. He has also been granted more than twenty U.S. patents. He is the recipient of the NSF CAREER award, the prestigious R&D 100 Award, the MIT Technology Review's 2011 Technology of the Year Award and the 2019 IEEE IAS Gerald Kliman Innovator Award. Dr. Huang is a fellow of National Academy of Inventors and IEEE
- [41] IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers, IEEE Standard C57.12.01-2015 (Revision of IEEE Standard C57.12.01-2005), 2015. -
Cited by
Li, Z., Hsieh, E., Li, Q., & Lee, F. C. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3279030 · Cited by 111
“device loss, and thermal performance, are frequently employed to optimize the HFT and related converters [20], [21], [32], [33].”
BackgroundMethodInfluentialAgarwal, R., Li, H., Guo, Z., & Cheetham, P. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3174243 · Cited by 79
Self-citationHardware Design of a 13.8-kV/3-MVA PV Plus Storage Solid-State Transformer (PVS-SST)
Xu, W., Guo, Z., Vetrivelan, A., Yu, R., & Huang, A. Q. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3082033 · Cited by 79
Self-citationCharacterization of Partial Discharges in High-Frequency Transformer Under PWM Pulses
Guo, Z., Huang, A. Q., Hebner, R., Montanari, G. C., & Feng, X. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3169747 · Cited by 79
Self-citationCzyż, P., Guillod, T., Zhang, D., Krismer, F., Huber, J., Färber, R., Franck, C. M., & Kolar, J. W. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3123793 · Cited by 69
Awais, M., Chen, X., Hong, Z., et al. (2022) · Composites Science and Technology · doi:10.1016/j.compscitech.2022.109576 · Cited by 61
A Novel High Insulation 100 kW Medium Frequency Transformer
Guo, Z., Rajendran, S., Tangudu, J. K., Khakpour, Y., Taylor, S., Xing, L., Xu, Y., Feng, X., & Huang, A. Q. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3205646 · Cited by 53
“Some latest published high-power MFTs with high insulation capability are given in Table I [5], [6], [7], [8], [9].”
BackgroundSelf-citationLi, S., Yu, X., Yuan, Y., Lu, S., & Li, T. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3305054 · Cited by 50
Song, Y.-H., Yin, L., Zhong, S., Feng, Q., Wang, H., Zhang, P., Xu, H., Tong, L., & Dang, Z. (2024) · Advanced Composites and Hybrid Materials · doi:10.1007/s42114-024-00914-6 · Cited by 44
“Most researchers believe the unfavorable thermal conductivity and dielectric loss of electrical insulating materials under high frequency and high voltage cause temperature accumulation (up to 100 °C) within the SST, resulting in rapid insulation failure [8, 9].”
Wang, T., & Yuan, J. (2022) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2022.3187206 · Cited by 42
Teng, J., Sun, X., Pan, Y., Liu, X., Zhang, Y., Zhao, W. M., & Li, X. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3144279 · Cited by 36
“[52] summarized several calculation methods of HFT loss, and the calculation formulas of core loss Pcore and winding loss Pw applicable to the modulation strategy in this article can be obtained from [53] and [54], and”
MethodYang, J., Li, R., Ma, K., et al. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3174300 · Cited by 28
“technology, the overall loss and volume of high-frequency medium voltage (MV) isolated dc–dc converter are reduced, and its power rating is further improved [3], [4].”
BackgroundA High-Efficiency 80-kW Split Planar Transformer for Medium-Voltage Modular Power Conversion
Lu, S., Kong, D., Xu, S., Luo, L., & Li, S. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3151796 · Cited by 31
Zhao, Z., Wu, Y., Diao, F. M., Lin, N., Du, X., Zhao, Y., & Zhu, G. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3161870 · Cited by 27
Pan, Y., Teng, J., Yang, C., Bu, Z., Wang, B., Li, X., & Sun, X. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3239164 · Cited by 24
“where PconT,P are the conduction loss, IrmsT,P are rms currents, RDS are the conduction resistance The power losses of HFT are mainly distributed on the magnetic core and winding, which can be calculated by the existing research [23], and expressed as ⎧⎪⎨ ⎪⎩ Pcore = fQ,S ∫ 1 fQ,S 0 ( K| dB(t) dt |α|B(t)|β−α (2π)α−1 ∫…”
Litz-Wire Winding Loss Calculation Method for Optimal Design of High-Frequency Transformers
Chen, T., Zhao, Z., Shen, Z., Jia, H., Ji, J., & Wang, H. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3361924 · Cited by 28
“Litz wire is widely utilized in power magnetic components that carry high-frequency alternating current (ac), such as the transformers and inductors of high-frequency resonant systems [5], [6], [7].”
BackgroundAwais, M., Chen, X., Dai, C., et al. (2021) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2021.009596 · Cited by 22
Teng, J., Sun, X., Zhang, Y., Fu, H., Liu, X., Zhao, W. M., & Li, X. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3137906 · Cited by 23
“Literature [50] and [51] discussed the high-frequency transformer insulation design in detailed.”
BackgroundArévalo-Cordero, P., Ochoa-Correa, D., & Villa‐Ávila, E. (2024) · Vehicles · doi:10.3390/vehicles7010001 · Cited by 34
“Silicon Carbide (SiC) [8,53,59].”
InfluentialLast Developments and New Technologies in Solid-State Transformer
Liserre, M., Costa, L. F., Guo, Z., D’Amato, D., Queiroz, S. S., & Huang, A. Q. (2024) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg61800.2024.10667423 · Cited by 29
“The latest progress in this matter has demonstrated that the MFT has achieved more than 99% of efficiency, 10 kW/L of power density, and 14 kV of isolation voltage [5].”
BackgroundSelf-citationA Low Loss Orthogonal Decoupling Magnetic Integrated Structure for Dual Active Bridge Converter
Cao, Z., Chen, W., Shen, Z., Chen, Y., Jin, L., Ma, D., & Zou, B. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3133068 · Cited by 19
“The parallel-concentric winding structure is selected as the HFT winding structure due to the least leakage inductance [13].”
BackgroundDual-Frequency Bands Grid Impedance Emulator for Stability Test of Grid-Connected Converters
Wang, J., Ma, K., Tang, W., Cai, X., Zheng, L., Li, X., & Wang, A. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3173958 · Cited by 17
Lu, R., Li, C., Yu, J., Li, C., Li, W., & He, X. (2023) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3304339 · Cited by 21
“First, for the insulation material, in [6] and [8] air is used for the main wall insulation.”
BackgroundLiu, Z., Zhu, L., Dang, Y., & Ji, S. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3566383 · Cited by 19
Li, H., Zhang, J., Zhou, J., Zang, J., Shi, G., Xu, J., & Cai, X. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3621603 · Cited by 30
“Moreover, the volume of the MFT is estimated based on the design specifications of [23], [24].”
Modeling of Litz Wire Winding AC Resistance Based on Improved Segmented Equivalent Circuit
Wang, Y., Chen, W., & Shen, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3321327 · Cited by 16
“T HE development of power electronics enables the wide-range applications of grid-connected renewable energy sources [1], [2], [3], e.g., photovoltaics, wind turbines, etc. High-frequency transformers play a vital role in those high-power converters [4], [5].”
BackgroundShi, B., Zhang, L., Jiang, Y., Li, Z., Xiao, W., Shang, J., Chen, X., & Li, M. (2023) · Energies · doi:10.3390/en16227575 · Cited by 16
Teng, J., Bu, Z., Sun, X., Fu, H., Zhao, W. M., & Li, X. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3153367 · Cited by 16
“Insulation design between windings [44].”
MethodLiu, Z., Zhu, L., Dang, Y., Zhan, C., & Ji, S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3512856 · Cited by 14
Zhang, X., Xiao, F., Wang, R., Kang, W., & Yang, B. (2022) · Energies · doi:10.3390/en15041361 · Cited by 16
Semi-Analytical AC Resistance Prediction Model for Litz Wire Winding in High-Frequency Transformer
Peng, C., Chen, G., Wang, B., & Song, J. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3293483 · Cited by 17
“Meanwhile, operating in the high-frequency range poses challenges for reducing winding losses due to eddy currents [2], [3].”
BackgroundMethodXiao, Y., Li, C., Guo, X., Liu, Y., & Zheng, Z. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3428861 · Cited by 10
“D printed two-layer bobbin structure and realized a 200 kW transformer prototype with 19.23 kW/L [11], but the optimization freedom degrees are only the number of turns of the primary and secondary sides, the geometric parameters of the bobbin and the frequency.”
InfluentialDesign and Testing of a Medium Frequency Transformer
Ren, X., Li, J., Weng, H., Wang, R., & Xu, D. (2021) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec42165.2021.9487310 · Cited by 10
Wang, T., Yuan, W., & Yuan, J. (2022) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2022.3153124 · Cited by 9
Design of Dry-type High-power High-frequency Transformer Based on Triangular Closed Core
Cao, Z., Chen, W., Jiang, J., Zhang, K., Chen, Y., & Shen, Z. (2021) · IEEE Sustainable Power and Energy Conference (iSPEC) · doi:10.1109/ispec53008.2021.9735925 · Cited by 11
“A 200kW/15kHz HFT is designed in [8], and a novel cooling structure that utilizes two layers 3D printed bobbins is adopted to guarantee insulation capability.”
BackgroundXu, W., Huang, P., Liu, Z., Zhao, M., Dian, R., Wang, P., Wang, Q., Wang, D., & Shen, T. (2022) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.12451 · Cited by 9
Self-citationLi, Z., Feng, J., Hsieh, Y.-H., & Li, Q. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131159 · Cited by 12
“To avoid the epoxy potting, some air-core based transformer is proposed using air as the insulation [22]-[23].”
MethodIlahi, T., Izhar, T., Zahid, M., Rasool, A., Tsamaase, K., Zahid, T., & Khan, E. M. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15020066 · Cited by 15
“A litz wire with 4000 strands is selected [39].”
BackgroundMultiport AC-AC-DC Converter for SNOP With One Medium-Frequency Transformer
Ma, D. (2022) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2022.00034 · Cited by 8
A High-Power, High-Frequency Matrix Core Transformer Design for Medium Voltage Dual Active Bridge
Zhao, Z., Wu, Y., Diao, F. M., Lin, N., Du, X., & Zhao, Y. (2022) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43599.2022.9773400 · Cited by 8
Guo, Z., Huang, A. Q., & Feng, X. (2022) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9948165 · Cited by 9
“[6] Z. Guo, S. Sen, S. Rajendran, Q. Huang, X. Feng and A. Q. Huang, "Design of a 200 kW Medium-Frequency Transformer (MFT) With High Insulation Capability," 2020 IEEE Energy Conversion Congress and Exposition (ECCE), 2020, pp. 3471-3477.”
InfluentialSelf-citationThe Full-Analytical Model of AC Loss for Hollow Copper Winding in Medium Frequency Transformer
Guo, X., Zheng, Z., & Li, C. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3254364 · Cited by 8
“3254364 Kolar and Alex Huang respectively adopt an air-core winding transformer [6], a complex heat dissipation structure of multiple water-cooling plates [7], and a novel cooling structure utilizing two layers of three-dimensional (3D) printed bobbins to provide airflow channels [2].”
BackgroundLi, C., Chen, T., Su, L., Zhang, Z., & Zheng, Z. (2025) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2024.3497412 · Cited by 7
Loss Analysis of a Resonant Converter Based Medium Voltage Single Stage Solar PV Inverter
Bhuvela, P., Taghavi, H., & Nasiri, A. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3553089 · Cited by 10
Three-Phase Medium-Voltage Medium-Frequency Transformer for SST in Green Hydrogen Production
Mirzadarani, R., Niasar, M. G., Li, Z., Qin, Z., Vaessen, P., Bauer, P., & Lieshout, L. V. (2023) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon51785.2023.10312546 · Cited by 8
Yang, X., Shu, L., & Yang, D. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3501573 · Cited by 8
A Novel Hybrid Core Structure for 100kW Medium Frequency Transformers
Chen, C., Guo, Z., Yu, R., et al. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362789 · Cited by 6
“This material holds low loss density, high saturation flux density, and excellent acoustic noise performance [1].”
BackgroundSelf-citationDevelopment of a High Power, Medium Frequency Transformer for Medium Voltage Applications
Shafei, A. E., Özdemir, Ş., Altın, N., & Nasiri, A. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362616 · Cited by 5
Guo, X., Cheng, X., Xiao, Y., Chen, J., Li, C., Zhao, X., Zheng, Z., Chen, Y., Li, Y., & Zhao, F. (2024) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2024.3364140 · Cited by 5
Guo, Z.-C., Cao, B., Chen, C., & Huang, A. Q. (2026) · IEEE transactions on power electronics · doi:10.1109/tpel.2026.3654531 · Cited by 6
“The single MFT archives 99.84% efficiency under 200 kW/15 kHz working conditions [31].”
InfluentialSelf-citationTong, L., Chen, Y., Cheng, C., Yu, C., Shang, Y., & Kang, Y. C. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3543192 · Cited by 6
Liu, Z., Zhu, L., Dang, Y., & Ji, S. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3610516 · Cited by 5
A High Power 200kW Medium Frequency Transformer With Improved Thermal Management
Guo, Z., Chen, C., Yu, R., & Huang, A. Q. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362391 · Cited by 4
Self-citationChen, C., Guo, Z., & Huang, A. Q. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509302 · Cited by 5
Self-citationThe Magnetic Branch Snubber Channel and Magnetic Model Analysis for SM Capacitor Reduction of SST
Pan, Y., Chen, Y., Teng, J., et al. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3539290 · Cited by 4
Korthauer, B., & Biela, J. (2025) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2025.3554299 · Cited by 6
“Due to high operating frequencies, MFTs often employ round [27] or profiled [28], [29] litz-wire windings, and sometimes foil windings [2], [8].”
Heat Extraction from Ferrite Cores Using Metallic Laminations
Brown, A., Nguyen, D. T., & Hanson, A. J. (2025) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48143.2025.10977461 · Cited by 5
Yang, B., Wang, R., Xiao, F., Zhang, X., Jie, G., Gao, S., Wang, H., & Kang, W. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3237721 · Cited by 4
“1) Conduction Thermal Resistance: The process of heat conduction: The heat transfers through an insulation structure of length lp with thermal conductivity kp and cross-section Sp, then the corresponding thermal resistance Rcd is [24]”
BackgroundInfluentialAn overview of power loss calculation methods for high-frequency litz wires
Chen, T., Zhao, Z., Ming, L., Shi, Z., Ge, Y., & Wang, H. (2024) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-230171 · Cited by 5
“Among passive components, the magnetic components, like inductors and transformers, can functionally provide energy storage, filtering, isolation, or transformer [8,9].”
Menicanti, S., Benedetto, M. D., & Crescimbini, F. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362578 · Cited by 4
“On the other hand, a more appropriate approach for sizing HFTs used in DAB converters should rely on a “Custom Design”, as early discussed in [17] and [18].”
MethodPriya, P., Das, A. K., Anand, S., & Fernandes, B. G. (2022) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon49645.2022.9968856 · Cited by 3
“are dual active bridge (DAB) converter [2]–[4] and series resonant converter (SRC) [5]–[7].”
BackgroundA High Power High Isolation Medium Frequency Transformer With A Planar Matrix Structure
Guo, Z., Chen, C., Chen, Z., & Huang, A. Q. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362495 · Cited by 4
Self-citationOgan, S. E., Song, C., Chakraborty, S., Geury, T., Davari, P., & Hegazy, O. (2025) · IEEE Access · doi:10.1109/access.2025.3550651 · Cited by 7
Song, J., Wang, J., Qin, Y., et al. (2025) · Energies · doi:10.3390/en18081938 · Cited by 2
Yadollahi, K., & Zakipour, A. (2025) · Scientific Reports · doi:10.1038/s41598-025-19533-2 · Cited by 5
“In 26 , horizontal and vertical coil structures were placed within a U-shaped transformer core in the DAB converter, and optimal transformer design was performed considering magnetic losses and minimizing leakage inductance.”
Magnetic Design of a 4.16 kV/1 MW Medium Voltage PV Plus Storage Solid State Transformer (PVS-SST)
Guo, Z., Xu, W., Vetrivelan, A., & Huang, A. Q. (2023) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec43580.2023.10131543 · Cited by 4
“The high-power mediumfrequency transformer (MFT) needs to consider the tradeoff among the competing objectives including reliable electrical insulation, high efficiency, high power density, and superior thermal performance [5-7].”
BackgroundSelf-citationExperimental and Simulation Study of Pulse Current Generator
Tunç, E., & Fidan, M. (2023) · Electric Power Components and Systems · doi:10.1080/15325008.2023.2269935 · Cited by 2
Liu, Z., Zhu, L., Dang, Y., Zhan, C., & Ji, S. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362551 · Cited by 2
A Mechanical Fault Diagnosis Approach for Transformer Winding Core Based on VMD and IGOA-KELM
Dong, M., Shi, J., Zhou, K., et al. (2024) · Asia Conference on Power and Electrical Engineering (ACPEE) · doi:10.1109/acpee60788.2024.10532740 · Cited by 2
“We count the MFE values of IMF1 for the four conditions mentioned above, and selects the scale factor interval as [1, 15].”
BackgroundMethodLu, S., Xu, S., Deng, J., Li, T., Li, S., Xia, J., & Zhao, D. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3522589 · Cited by 3
“OneofthekeydesignchallengesforMFTsistoeffectively balancemultiplecompetingobjectives,whichincludehigheffi-ciency,high-powerdensity,highelectricalinsulation,andthe superiorthermalperformancesimultaneously[9],[10],[11], [12],[13].”
Practical Design of A Dry-type 200kVA 10kHz Transformer With Nanocristalline Core
Chen, Y., Chen, W., Cao, Z., Jiang, J., & Shen, Z. (2021) · IEEE Sustainable Power and Energy Conference (iSPEC) · doi:10.1109/ispec53008.2021.9735732 · Cited by 2
“And the structure of the windings is parallel-concentric for its best coupling[19] to minimize the leakage inductance in which the windings on the same side should be symmetrically distributed on the two magnetic core legs and connected in series.”
BackgroundWu, X., Ai, Q., Chen, H., et al. (2024) · Asia Conference on Power and Electrical Engineering (ACPEE) · doi:10.1109/acpee60788.2024.10532634 · Cited by 2
“Therefore, the MPE values relying on scale factors within the scope of [1,10] can be regarded as feature quantities to form feature datasets.”
BackgroundLee, J., Kim, D., Kim, S., & Lee, S.-H. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3417993 · Cited by 4
Current Harmonics Suppression Scheme for Hysteresis Current Based ZVS Grid-Tied Inverters
Zhang, L., Zheng, Z., Lei, Z., et al. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3574387 · Cited by 1
“R ECENTLY, to enhance power density, wide bandgap (WBG) devices, such as silicon carbide (SiC) MOSFETs, have been extensively employed in grid-tied inverters to increase the switching frequency [1], leveraging their superior material properties [2], [3].”
Budiwicaksana, L. A., & Lee, D. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3617499 · Cited by 1
Thermal Analysis of Ceramic-Based and FR4-Based Planar Coils
Luan, S., Takahashi, M., Yan, Z., et al. (2025) · doi:10.1109/ecce58356.2025.11259803 · Cited by 1
“However, with the maturation of wide-bandgap semiconductors, both the power level and the switching frequency of power electronics have been further increased [5] [6], where the magnetic components will have more losses and smaller volumes [7] [8].”
Zhang, X., Xiao, F., Wang, R., et al. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3661080 · Cited by 1
Noh, E., So, J., Park, J.-H., & Lee, S.-H. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2026.3663785 · Cited by 3
“2 shows four typical MFT winding structures commonly used in previous studies [28]: 1) horizontally separated (HS); 2) vertically separated (VS); 3) parallel-concentric (PC); and 4) central-concentric (CC).”
Armstrong, G., & Bhattacharya, I. (2026) · Proceedings of IEEE Southeastcon · doi:10.1109/southeastcon63549.2026.11476547 · Cited by 1
Medium Voltage Conversion Systems with Integrated Galvanic Isolation for Hybrid Photovoltaic Plants
Nguyen, D.-H., Martin, J., Gaillard, A., & Tran, Q. T. (2026) · Solar · doi:10.3390/solar6030018 · Cited by 1
“Moreover, the optimal solution may vary depending on the specific application in which the MFT is implemented [28].”
Flatwise Windings for Improved Thermal Management in High Power Transformer Applications
Roque, K. R., Masuda, I., Choi, S., Imaoka, J., Yamamoto, M., Kauhanen, M., & Tashiro, K. (2026) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec51134.2026.11516701 · Cited by 1
“Other solutions optimize active cooling systems, such as forced air or liquid cooling [5]–[7], and may incorporate custom cooling channels [8], [9] or additional thermal elements [10] to more effectively extract heat directly from the windings.”
Transformer Design for Solid-State Transformer (SST)-Based EV Charging Station Applications
Younis, E. A., Zayed, O., Elezab, A., Ibrahim, M., & Narimani, M. (2023) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec55900.2023.10187097 · Cited by 2
“Some latest published high-power MFT designs in literature are listed in Table III [18], [19], [20], [21], [22], [23], [24], [25].”
BackgroundThermal characteristics analysis of medium frequency transformer under multiple working conditions
Huang, P., Shen, T., Liu, Z., Dian, R., Xu, W., & Wang, D. (2023) · Thermal Science · doi:10.2298/tsci230807239h · Cited by 1
Self-citationDas, A. K., & Fernandes, B. G. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861396 · Cited by 1
Zhou, L., Expósito, A. D., Ruszczyk, A., Round, S. D., & Vasić, M. (2025) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48143.2025.10977408 · Cited by 4
Simulation of a Custom Core, 15kV Isolated Gap Transformer Optimized for High Power Density
Galamb, A., Teng, F., & Lukic, S. M. (2025) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48143.2025.10977450 · Cited by 1
Huang, P., Dian, R., Wang, P., Wang, D., Liu, Z., & Wang, Q. (2021) · Energies · doi:10.3390/en14113285 · Cited by 4
“[22] proposes a novel cooling and insulation structure based on the parallel-concentric winding concept.”
BackgroundHan, K., Zheng, Z., & Zhang, L. (2022) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec54735.2022.9846326
Dube, S. K., Nair, R., & Das, P. (2022) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9948134
“[8] Same as above Same as above High coupling of fluxes, increased EMI and AC copper loss Same as above”
BackgroundA Novel Dual-Active-Bridge Converter for Electric Vehicle Charging Station
Yang, F., Qi, C., Wang, W., Yang, F., Wang, W., & Li, R. (2023) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon51785.2023.10312116
“Magnetic flux density and voltage potential distribution are also plotted[7]. k is defined as the voltage transmission ratio which is determined by k = V in /n V o .”
BackgroundSolid-state transformer and magnetic properties with potential topologies
Li, Y., Yang, M., & Bahman, A. S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-85622-5.00009-2
Yang, X., Shu, L., & Yang, D. (2024) · doi:10.36227/techrxiv.171436020.02962844/v1
Liu, Z., Zhu, L., Dang, Y., & Ji, S. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567304
“The core loss can account for 30%-60% of the total power loss [4]-[6].”
BackgroundYou, Y., Shao, K., Fan, X., Yu, M., Lin, X., Qi, L., & Teng, J. (2024) · Electronics · doi:10.3390/electronics13214268
Hou, N. (2024) · Synthesis lectures on power electronics · doi:10.1007/978-3-031-72963-8_1
Luo, Y., Wang, W., Wang, Z., et al. (2024) · doi:10.1109/isesc63657.2024.10785398
“With the wide demand for high-capacity power electronic transformers in medium voltage distribution networks, offshore wind power lightweight, data centers, new energy charging stations, aviation ships, etc., HFT need to be upgraded to more than 100kW [1] .”
Fang, S., Shu, S., Wang, G., Wang, K., Zeng, J., & Shi, G. (2025) · Asia Energy and Electrical Engineering Symposium (AEEES) · doi:10.1109/aeees64634.2025.11019076
“Additionally, it can cause the internal temperature of the magnetic core to rise, reducing its service life [6-8].”
Design of Dual Medium-Voltage Transformer Stations: Methodology Showcase
Ištvanović, M., Šimović, V., & Cvetković, A. (2025) · International Conference on Smart and Sustainable Technologies (SpliTech) · doi:10.23919/splitech65624.2025.11091723
Evaluating Core Loss Effects in Toroidal Current Transformers:A Simulation-Based Comparative Study
Güney, E. (2025) · International Conference on Control, Automation and Diagnosis (ICCAD) · doi:10.1109/iccad64771.2025.11099193
“The nonlinear growth of power loss aligns with Steinmetz’s equation for core losses, which states that hysteresis and eddy current losses increase exponentially with frequency [20].”
Design and analysis of 15-level inverter with a new voltage level generation method
Hataş, H. (2025) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2025.103679
Metadata
- Authors
- Guo, Z., Yu, R., Xu, W., Feng, X., & Huang, A. Q.
- Affiliations
- The University of Texas at Austin (US)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2021-09
- Volume
- 36
- Issue
- 9
- Pages
- 10548-10560
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W3131410230
- Cited by
- 115
- References
- 41
- Citations by year
- 2026: 20 · 2025: 21 · 2024: 23 · 2023: 22 · 2022: 20 · 2021: 9
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- green
- www.osti.gov
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Department of Energy
- Office of Energy Efficiency and Renewable Energy
- Solar Energy Technologies Office (EE0008348)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties and Applications
- Keywords
- medium frequency transformer, leakage inductance reduction, partial discharge testing, dual active bridge converter, transformer design optimization, power density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.