CoChat

Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters

Open access
Guo, Zhicheng, Yu, Ruiyang, Xu, Wei, Feng, Xianyong, Huang, Alex Q. · 2021 · IEEE Transactions on Power Electronics

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index; 2 of the 31 sources its claims cite were checked for support.

Abstract

This article presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.

Overview

CoChat Summary

TL;DR

This paper presents a three-stage optimal design methodology for a 200-kW, 15-kHz medium-frequency transformer (MFT) using FINEMET® FT-3TL nanocrystalline cores and a parallel-concentric winding structure. The prototype achieves >19.23 kW/L power density, PD-free operation up to 5.3 kV RMS/7.5 kV peak, and 99.842% MFT efficiency at 200 kW in a 200-kW DAB converter.

Key findings

  • The parallel-concentric winding structure gave the lowest measured leakage inductance among compared structures: 2.6 µH and a leakage-to-magnetizing inductance ratio of 0.023%; the final prototype reported 5.36 µH / 21.67 mH (0.0247%).
  • The optimized MFT prototype achieved a power density higher than 19.23 kW/L, with insulation tested at 12 kV AC peak and partial discharge (PD) testing at 7.5 kV AC peak; measured PDIV was about 5.3 kV RMS/7.5 kV peak, with PD smaller than 50 pC and PD rate much less than 1 pulse/cycle.
  • In the 200-kW DAB converter, the peak DAB efficiency was 99.53% at 50 kW and 98.85% at 200 kW; the MFT peak efficiency was 99.844% at around 180 kW and 99.842% at 200 kW.
  • At 200 kW, measured maximum core surface temperature rise was about 25 °C and winding temperature rise was 23 °C; the paper states MFT core temperature rise at 200 kW is lower than 30 °C.

Methods

  • Design and optimization methodology with three stages: predesign, preliminary design, and optimal design; it selects magnetic core material/dimensions, Litz wire, insulation materials, and winding structure, then sweeps free parameters such as switching frequency, turns number, and bobbin dimensions.
  • Core loss evaluation compared OSE, MSE, GSE, and IGSE models, with IGSE selected; winding loss used Dowell’s model and FFT-based harmonic summation; thermal design used a detailed steady-state thermal network and fluid/thermal simulation.
  • Experimental verification used a 200-kW DAB converter with 1700-V SiC MOSFET modules, 1300-V input, and 15-kHz operation; PD testing was based on IEC 60270, and DAB efficiency was measured with a HIOKI PW6001 power analyzer, while MFT efficiency was calculated from experimental core and winding loss information.

Limitations

  • The paper does not include an explicit limitations section.
  • Evident from the text: although high-frequency bipolar PWM insulation/PD testing is claimed as first applied in MFT design and test, the developed MFT’s PD detection was performed with a 60-Hz sine wave because no well-established standard method exists for reliable PD measurement under PWM excitations.
  • Evident from the text: MFT efficiency is reported as calculation efficiency based on experimental core and winding losses, rather than as a directly measured transformer efficiency.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1109/tpel.2021.3059879

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

1 Valid · 7 Not valid · 11 Not checked · 79 Own results and interpretations

46 more claims

Create a free account to see all 98 claims and to verify the 1 reference still open.

See all claims — free account
  • Probably not a substantial claim. 26
  • It may state two separate claims as one. 30
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Research works printed but not linked: 3

  1. 10.1109/ICPE · doi:10.1109/icpe
  2. [42] IEC 60270:2000: High-voltage test techniques - Partial discharge measurements. <!-- image --> <!-- image --> Zhicheng Guo (S'20) was born in Suzhou, China. He received his B.Sc. degree from Southeast University, Nanjing in 2013, and M.S. from National Tsing Hua University, Hsinchu in 2016. He is currently pursuing the Ph.D. degree with the Semiconductor Power Electronics Center, the University of Texas at Austin, Austin, TX, USA. His research interests include the high-power magnetic design, power module packaging. Ruiyang Yu (S'08 -M'13)received the B.E. degree in electrical engineering from Shandong University, Jinan, China, in 2007, and the M.S. and Ph.D. degrees in power electronics from The University of Hong Kong, Hong Kong, in 2008 and 2013, respectively. He was a Post-Doctoral Research Fellow from 2013 to 2017 and an instructor in 2016 with North Carolina State University, Raleigh, NC, USA. He is currently a Research Associate with The University of Texas at Austin, Austin, TX, USA. His research interests include high-frequency and high-power-density power converter design, megawatt power converter design, magnetic components and power converter control. <!-- image --> Wei Xu (S'20) received his B.S and M.S. degree in electrical engineering from Anhui University of technology and Nanjing University of Aeronautics and Astronautics in 2011 and 2014, respectively. He was a senior hardware engineer from 2014 to 2018 with the High-Power Research Team (HPRT), DELTA Electronics, Shanghai, China. He is currently a PhD student at The University of Texas at Austin, Texas, USA. His research interests include high power, high frequency and high- density power converters, magnetic component designs, and power converter control. <!-- image --> <!-- image --> Xianyong Feng (M'12) received a Ph.D. degree in electric power engineering from the Department of Electrical and Computer Engineering at Texas A&M University, College Station, TX, USA, in May 2012. He is currently with the Center for Electromechanics at the University of Texas at Austin, TX. Previously, he worked at ABB, Raleigh, NC, and ExxonMobil, Houston, TX. His research interests include the areas of microgrids, shipboard power systems, and dc power system protection. Alex Q. Huang (S'91 -M'94 -SM'96 -F'05) was bor n in Zunyi, Guizhou, China. He received his B.Sc. degree from Zhejiang University, China in 1983 and his M.Sc. degree from Chengdu Institute of Radio Engineering, China in 1986, both in electrical engineering. He received his Ph.D. from Cambridge University, UK in 1992. From 1992 to 1994, he was a research fellow at Magdalene College, Cambridge. From 1994 to 2004, he was a professor at the Bradley Department of Electrical and Computer Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia. From 2004 to 2017, he was the Progress Energy Distinguished Professor of Electrical and Computer Engineering at NC State University where he established and led the NSF FREEDM Systems Center. Since 2017, he has become the Dula D. Cockrell Centennial Chair in Engineering at University of Texas at Austin. Since 1983, he has been involved in the development of modern power semiconductor devices and power integrated circuits. He fabricated the first IGBT power device in China in 1985. He is the inventor and key developer of the emitter turn-off (ETO) thyristor. He developed the concept of Energy Internet and the smart transformer based Energy Router technology. His current research interests are power electronics, power management microsystems and power semiconductor devices. He has mentored and graduated more than 80 Ph.D. and master students, and has published more than 500 papers in international conferences and journals. He has also been granted more than twenty U.S. patents. He is the recipient of the NSF CAREER award, the prestigious R&D 100 Award, the MIT Technology Review's 2011 Technology of the Year Award and the 2019 IEEE IAS Gerald Kliman Innovator Award. Dr. Huang is a fellow of National Academy of Inventors and IEEE
  3. [41] IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers, IEEE Standard C57.12.01-2015 (Revision of IEEE Standard C57.12.01-2005), 2015. -

Cited by

See all 115

Metadata

Authors
Guo, Z., Yu, R., Xu, W., Feng, X., & Huang, A. Q.
Affiliations
The University of Texas at Austin (US)
Venue
IEEE Transactions on Power Electronics
Published
2021-09
Volume
36
Issue
9
Pages
10548-10560
ISSN
  • 0885-8993 (ISSN-L)
  • 1941-0107
OpenAlex
W3131410230
Cited by
115
References
41
Citations by year
2026: 20 · 2025: 21 · 2024: 23 · 2023: 22 · 2022: 20 · 2021: 9
FWCI
5.43
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Power Electronics (publishedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
Funders
  • U.S. Department of Energy
  • Office of Energy Efficiency and Renewable Energy
  • Solar Energy Technologies Office (EE0008348)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties and Applications
Keywords
medium frequency transformer, leakage inductance reduction, partial discharge testing, dual active bridge converter, transformer design optimization, power density

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.