Stochastic Assessment of Voltage Unbalance Due to Single-Phase-Connected Solar Power
The DOI matches its Crossref record.
Abstract
A stochastic method is presented in this paper to estimate the future voltage unbalance in a low-voltage distribution network with high-penetration of single-phase photovoltaic inverters (PVIs). The location and phase allocation of the PVIs are considered as input parameters for the stochastic simulation. The method has been applied to three different low-voltage networks: two in Sweden and one in Germany. In the Swedish networks, for 6-kW single-phase PVIs, it is likely that the contribution from single-phase photovoltaic inverters to the voltage unbalance exceeds 1%. The 2% value is unlikely to be exceeded. In the German network, for 4.6-kW single-phase PVIs, the voltage unbalance is between 1.35% and 2.62%. The risk of high-voltage unbalance can be reduced by a combination of controlled distribution over the phases and a reduction of the maximum size for a single-phase PVI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
State-of-the-art of hosting capacity in modern power systems with distributed generation
Ismael, S. M., Abdel Aleem, S. H. E., Abdelaziz, A. Y., & Zobaa, A. F. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.07.008 · Cited by 599
Review of power system impacts at high PV penetration Part I: Factors limiting PV penetration
Gandhi, O., Kumar, D. S., Rodríguez-Gallegos, C. D., & Srinivasan, D. (2020) · Solar Energy · doi:10.1016/j.solener.2020.06.097 · Cited by 290
Mulenga, E., Bollen, M. H. J., & Etherden, N. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105445 · Cited by 271
Self-citationA Comprehensive Assessment of PV Hosting Capacity on Low-Voltage Distribution Systems
Torquato, R., Salles, D., Oriente Pereira, C., Meira, P. C. M., & Freitas, W. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2798707 · Cited by 270
Methods and strategies for overvoltage prevention in low voltage distribution systems with PV
Hashemi, S., & Østergaard, J. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0277 · Cited by 212
Kharrazi, A., Sreeram, V., & Mishra, Y. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109643 · Cited by 193
Bollen, M., & Rönnberg, S. (2017) · Energies · doi:10.3390/en10091325 · Cited by 169
“In [39] the same networks were used as in Section 4.”
BackgroundMethodSelf-citationKoirala, A., Van Acker, T., D’hulst, R., & Van Hertem, D. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111899 · Cited by 118
Umoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71
Mulenga, E., Bollen, M. H. J., & Etherden, N. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.106928 · Cited by 67
Self-citationMulenga, E., Bollen, M. H. J., & Etherden, N. (2021) · Electricity · doi:10.3390/electricity2030023 · Cited by 25
“4 kV, and Dyn11 (vector group) transformer with a 4% impedance supplies power to the 6-customer network [33].”
BackgroundSelf-citationKharrazi, A., Sreeram, V., & Mishra, Y. (2017) · 2017 Australasian Universities Power Engineering Conference (AUPEC) · doi:10.1109/aupec.2017.8282506 · Cited by 23
Combined PV-PEV Hosting Capacity Analysis in Low-Voltage Distribution Networks
e Silva, L. E. S., & Vieira, J. P. A. (2022) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.107829 · Cited by 20
Azaioud, H., Claeys, R., Knockaert, J., Vandevelde, L., & Desmet, J. (2021) · Energies · doi:10.3390/en14051420 · Cited by 17
Hou, Y., Givisiez, A. G., Liu, M. Z., & Ochoa, L. F. (2025) · Sustainable Energy, Grids and Networks · doi:10.1016/j.segan.2024.101615 · Cited by 7
Metadata
- Authors
- Schwanz, D., Moller, F., Ronnberg, S. K., Meyer, J., & Bollen, M. H. J.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2017-04
- Volume
- 32
- Issue
- 2
- Pages
- 852-861
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2414018509
- Cited by
- 97
- References
- 0
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.