Comprehensive Modeling of Three-Phase Distribution Systems via the Bus Admittance Matrix
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The theme of this paper is three-phase distribution system modeling suitable for the Z-Bus load-flow. Detailed models of wye and delta constant-power, constant-current, and constant-impedance loads are presented. Models of transmission lines, step-voltage regulators, and transformers that build the bus admittance matrix (Y-Bus) are laid out. The Z-Bus load-flow is then reviewed and the singularity of the Y-Bus in case of certain transformer connections is rigorously discussed. Based on realistic assumptions and conventional modifications, the invertibility of the Y-Bus is proved. Last but not least, MATLAB scripts that model the components of the IEEE 37-bus, the IEEE 123-bus, the 8500-node feeders, and the European 906-bus low-voltage feeder are provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-phase power flow calculations using the current injection method
Garcia, P. A. N., Pereira, J. L. R., Carneiro, S., da Costa, V. M., & Martins, N. (2000) · IEEE Transactions on Power Systems · doi:10.1109/59.867133 · Cited by 438 · cited 1×
“A N accurately constructed bus admittance matrix (YBus) that captures the unbalanced characteristics of distribution networks is the basis of several applications such as 1) three-phase load-flow based on Newton-Raphson [1], the current injection method [2], or the Z-Bus method [3]; 2) three-phase optimal power flow (…”
MethodDistribution System Modeling and Analysis
Kersting, W. H. (2001) · doi:10.1201/9781420041736 · Cited by 354
Beyond Relaxation and Newton–Raphson: Solving AC OPF for Multi-Phase Systems With Renewables
Zamzam, A. S., Sidiropoulos, N. D., & Dall'Anese, E. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2645220 · Cited by 77
Cited by
Integrating P2P Energy Trading With Probabilistic Distribution Locational Marginal Pricing
Morstyn, T., Teytelboym, A., Hepburn, C., & McCulloch, M. D. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2963238 · Cited by 182
“To obtain a linear power flow model, the nonlinear power flow is solved using the Z-bus method [43], for intervals across the day for nominal operation with pch it = 0, pdis it = 0, p it = p̂ pv it .”
MethodOn the impact of different voltage unbalance metrics in distribution system optimization
Girigoudar, K., & Roald, L. A. (2020) · Electric Power Systems Research · doi:10.1016/j.epsr.2020.106656 · Cited by 68
Data-Driven-Aided Linear Three-Phase Power Flow Model for Distribution Power Systems
Liu, Y., Li, Z., & Zhou, Y. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3130301 · Cited by 57
Rahman, O., Muttaqi, K. M., & Sutanto, D. (2018) · 2018 Australasian Universities Power Engineering Conference (AUPEC) · doi:10.1109/aupec.2018.8758001 · Cited by 7
Voltage Regulation in Rooftop PV-Rich Distribution Networks: A Review and Detailed Case Study
Rahman, O., Elphick, S., & Robinson, D. A. (2026) · Electronics · doi:10.3390/electronics15051074 · Cited by 3
Metadata
- Authors
- Bazrafshan, M., & Gatsis, N.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2018-03
- Volume
- 33
- Issue
- 2
- Pages
- 2015-2029
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2620296980
- Cited by
- 126
- References
- 3
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comprehensive Modeling of Three-Phase Distribution Systems via the Bus Admittance Matrix. https://app.cochat.ai/papers/10.1109/tpwrs.2017.2728618
- The paper
- Bazrafshan, M., & Gatsis, N. (2018). Comprehensive Modeling of Three-Phase Distribution Systems via the Bus Admittance Matrix. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2017.2728618
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.