A Generalized False Data Injection Attacks Against Power System Nonlinear State Estimator and Countermeasures
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
This paper develops a generalized framework that allows us to investigate the vulnerability of the power system nonlinear state estimator to false data injection attacks (FDIAs) from the operator's perspective and to initiate some countermeasures. Unlike most existing FDIA methods, which assume a perfect knowledge of the system measurements and topology by a hacker, we derive and analyze the uncertainties for launching successful FDIAs along with their upper bounds. To effectively defend against an FDIA, we propose a robust detector that checks the measurement statistical consistency using a subset of secure PMU measurements. We first show that if these secure PMU measurements are free of bad data while making the system observable, the FDIA is detectable. We then show that detectability is also ensured if these conditions are relaxed while using alternative redundant measurements from short-term nodal synchrophasor predictions together with the robust Huber M-estimator. Numerical simulation results on the IEEE 30-bus and 118-bus systems demonstrate the effectiveness and robustness of the proposed method even the secure measurements contain noise and bad data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huber, P. J. (1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250 · Cited by 7,066
Abur, A., & Expósito, A. G. (2004) · CRC Press eBooks · doi:10.1201/9780203913673 · Cited by 2,974 · cited 3×
“After estimation, the 2-norm detector is applied to detect the existence of bad data by checking if the following inequality holds [6], [21]:”
MethodFalse data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2011) · ACM Transactions on Information and System Security · doi:10.1145/1952982.1952995 · Cited by 2,428
Malicious Data Attacks on the Smart Grid
Kosut, O., Jia, L., Thomas, R. J., & Tong, L. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2163807 · Cited by 784 · cited 3×
“Once some measurements are compromised, the distribution of the estimated state vector will be perturbed by the attack [2], [14].”
BackgroundVulnerability Assessment of AC State Estimation With Respect to False Data Injection Cyber-Attacks
Hug, G., & Giampapa, J. A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2195338 · Cited by 595 · cited 7×
“ever, with the exception of [17]–[20], the bulk of the literature”
BackgroundMethodInfluentialStrategic Protection Against Data Injection Attacks on Power Grids
Kim, T. T., & Poor, H. V. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2119336 · Cited by 570 · cited 5×
“Indeed, the authors in [9] make use of a DC not an AC state estimation model.”
BackgroundMethodInfluentialModeling Load Redistribution Attacks in Power Systems
Yuan, Y., Li, Z., & Ren, K. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2123925 · Cited by 545 · cited 1×
“Following this work, three types of FDIAs were pinpointed and investigated, including state attacks [1], [2], topology attacks [3], [4] and load redistribution attacks [5].”
BackgroundDetecting False Data Injection Attacks on DC State Estimation
Bobba, R. B., Rogers, K. M., Wang, Q., Khurana, H., Nahrstedt, K., & Overbye, T. J. (2010) · Cited by 448
Detecting False Data Injection Attacks on Power Grid by Sparse Optimization
Liu, L., Esmalifalak, M., Ding, Q., Emesih, V. A., & Han, Z. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2284438 · Cited by 446 · cited 1×
“They include measurement protection-based approaches [8]–[11], sparse optimization or game theory-based approaches [12], [13], innovation-based approaches [14], [15], robust estimation-based approaches [16], to name a few.”
On Topology Attack of a Smart Grid: Undetectable Attacks and Countermeasures
Kim, J., & Tong, L. (2013) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2013.130712 · Cited by 298 · cited 1×
“Following this work, three types of FDIAs were pinpointed and investigated, including state attacks [1], [2], topology attacks [3], [4] and load redistribution attacks [5].”
Background
Cited by
Detection of False Data Injection Attacks in Smart Grid: A Secure Federated Deep Learning Approach
Li, Y., Wei, X., Li, Y., Dong, Z., & Shahidehpour, M. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3204796 · Cited by 393
A Cyber-Attack Resilient Distributed Control Strategy in Islanded Microgrids
Zhou, Q., Shahidehpour, M., Alabdulwahab, A., & Abusorrah, A. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.2979160 · Cited by 202
“Then, FDI attacks can impede MG functionalities, including frequency/voltage restoration [10]–[12], load sharing [13], and state estimation [14].”
BackgroundReda, H. T., Anwar, A., & Mahmood, A. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112423 · Cited by 197
Metadata
- Authors
- Zhao, J., Mili, L., & Wang, M.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2018-09
- Volume
- 33
- Issue
- 5
- Pages
- 4868-4877
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2791047555
- Cited by
- 202
- References
- 27
- FWCI
- 12.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.