Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation

Berkelman, P.J., Whitcomb, L.L., Taylor, R.H., Jensen, P. · 2003 · IEEE Transactions on Robotics and Automation

Abstract

This paper reports the development of a new miniature force sensor designed to measure contact forces at the tip of a microsurgical instrument in three dimensions, and its application to scaled force feedback using a cooperatively manipulated microsurgical assistant robot. The principal features of the sensor are its small size of 12.5 mm in diameter and 15 mm in height, a novel configuration of flexure beams and strain gauges in order to measure forces isotropically at the instrument tip 40 mm from the sensor body, and sub-mN three-axis force-sensing resolution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tra.2003.817526

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 14

  1. 10.1007/10704282_132 · DOI · Paper page
  2. 10.1109/IEMBS.1999.804019 · DOI
  3. 10.1109/IEMBS.1997.757046 · DOI · Paper page
  4. 10.1109/3516.662865 · doi:10.1109/3516.662865
  5. 10.1007/BFb0056225 · DOI · Paper page
  6. 10.1007/10704282_112 · DOI
  7. Taylor, 1996, A telerobotic assistant for laparoscopic surgery, 581
  8. 10.1109/70.294202 · DOI · Paper page
  9. 10.1007/BFb0029301 · DOI
  10. 10.1109/51.391774 · DOI
  11. 10.1007/BFb0029298 · DOI
  12. 10.1109/TRA.2002.999642 · DOI · Paper page
  13. 10.1109/ROBOT.2000.844120 · DOI
  14. 10.1007/978-3-540-40899-4_93 · DOI

Cited by

See all 171

Metadata

Authors
Berkelman, P. J., Whitcomb, L. L., Taylor, R. H., & Jensen, P.
Venue
IEEE Transactions on Robotics and Automation
Published
2003-10
Volume
19
Issue
5
Pages
917-922
ISSN
1042-296X (ISSN-L)
OpenAlex
W2108817574
Cited by
171
References
1
FWCI
7.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.