The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation
Abstract
This paper reports the development of a new miniature force sensor designed to measure contact forces at the tip of a microsurgical instrument in three dimensions, and its application to scaled force feedback using a cooperatively manipulated microsurgical assistant robot. The principal features of the sensor are its small size of 12.5 mm in diameter and 15 mm in height, a novel configuration of flexure beams and strain gauges in order to measure forces isotropically at the instrument tip 40 mm from the sensor body, and sub-mN three-axis force-sensing resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Self-citation
Research works printed but not linked: 14
- 10.1007/10704282_132 · DOI · Paper page
- 10.1109/IEMBS.1999.804019 · DOI
- 10.1109/IEMBS.1997.757046 · DOI · Paper page
- 10.1109/3516.662865 · doi:10.1109/3516.662865
- 10.1007/BFb0056225 · DOI · Paper page
- 10.1007/10704282_112 · DOI
- Taylor, 1996, A telerobotic assistant for laparoscopic surgery, 581
- 10.1109/70.294202 · DOI · Paper page
- 10.1007/BFb0029301 · DOI
- 10.1109/51.391774 · DOI
- 10.1007/BFb0029298 · DOI
- 10.1109/TRA.2002.999642 · DOI · Paper page
- 10.1109/ROBOT.2000.844120 · DOI
- 10.1007/978-3-540-40899-4_93 · DOI
Cited by
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
Self-citationMedical Robotics and Computer-Integrated Surgery
Taylor, R. H., Menciassi, A., Fichtinger, G., Fiorini, P., & Dario, P. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_63 · Cited by 325
Self-citationNew steady-hand Eye Robot with micro-force sensing for vitreoretinal surgery
Uneri, A., Balicki, M. A., Handa, J., Gehlbach, P., Taylor, R. H., & Iordachita, I. (2010) · 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2010.5625991 · Cited by 291
Self-citationMicron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270
Iordachita, I., Sun, Z., Balicki, M., Kang, J. U., Phee, S. J., Handa, J., Gehlbach, P., & Taylor, R. (2009) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0301-6 · Cited by 181
Self-citation
Metadata
- Authors
- Berkelman, P. J., Whitcomb, L. L., Taylor, R. H., & Jensen, P.
- Venue
- IEEE Transactions on Robotics and Automation
- Published
- 2003-10
- Volume
- 19
- Issue
- 5
- Pages
- 917-922
- ISSN
- 1042-296X (ISSN-L)
- OpenAlex
- W2108817574
- Cited by
- 171
- References
- 1
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.