The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Advanced Power Electronic Conversion and Control System for Universal and Flexible Power Management
Abstract
The future electricity network has to be able to manage energy coming from different grids as well as from renewable energy sources (RES) and other distributed generation (DG) systems. Advanced power electronic converters can provide the means to control power flow and ensure proper and secure operation of future networks. This paper presents analysis, design, and experimental validation of a back-to-back three-phase ac-dc-ac multilevel converter employed for universal and flexible power management (UNIFLEX-PM) of future electrical grids and its advanced control technique. The proposed system has been successfully tested for bidirectional power flow operation with different grid operating conditions such as voltage unbalance, frequency variation, harmonic distortion, and faults due to short circuits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Neutral-Point-Clamped PWM Inverter
Nabae, A., Takahashi, I., & Akagi, H. (1981) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1981.4503992 · Cited by 5,139
High‐Power Converters and ac Drives
Wu, B. (2006) · Wiley eBooks · doi:10.1002/0471773719 · Cited by 1,640
High‐Power Converters and AC Drives
Wu, B., & Narimani, M. (2017) · doi:10.1002/9781119156079 · Cited by 1,571
Predictive Current Control of a Voltage Source Inverter
Rodriguez, J., Pontt, J., Silva, C. A., Correa, P., Lezana, P., Cortes, P., & Ammann, U. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888802 · Cited by 1,563
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
A Comparison of Diode-Clamped and Cascaded Multilevel Converters for a STATCOM With Energy Storage
Cheng, Y., Qian, C., Crow, M. L., Pekarek, S., & Atcitty, S. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882022 · Cited by 336
A comparison of high-power converter topologies for the implementation of FACTS controllers
Soto, D., & Green, T. C. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.803217 · Cited by 288
Multilevel converters for high power AC drives: a review
Marchesoni, M., & Mazzucchelli, M. (2002) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.1993.268818 · Cited by 113
Recent Advances in High-Voltage Direct-Current Power Transmission Systems
Agelidis, V. G., Demetriades, G. D., & Flourentzou, N. (2006) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2006.372391 · Cited by 109
A Novel DC Voltage Detection Technique in the CHB Inverter-Based STATCOM
Li, Y., & Wu, B. (2008) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2008.919251 · Cited by 99
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Hierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Solid-State Transformers: On the Origins and Evolution of Key Concepts
Huber, J. E., & Kolar, J. W. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2588878 · Cited by 449
Hybrid ac/dc microgrids—Part I: Review and classification of topologies
Unamuno, E., & Barrena, J. A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.194 · Cited by 399
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“The detailed specifications of many well-known MVSST designs are depicted in Table 7, including designs by Siemens [97], Bombardier [102], Alstom [103], GE Global Research [104], UNIFLEX [105], ABB PETT [106], ETH [107], EPRI [108], Hubei Lab [98], ABB [98] and the FREEDM System Center [99], [100], [109] Table 4 clear…”
BackgroundDesign and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324
Medium-Voltage Solid-State Transformer: Technology for a Smarter and Resilient Grid
Huang, A. Q. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2589061 · Cited by 305
Intergrid: A Future Electronic Energy Network?
Boroyevich, D., Cvetkovic, I., Burgos, R., & Dong, D. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2276937 · Cited by 262
15 kV SiC MOSFET: An Enabling Technology for Medium Voltage Solid State Transformers
FREEDM Systems Center, N. C. S. U., & Huang, A. Q. (2017) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2017.00012 · Cited by 182
Zhu, Q., Wang, L., Huang, A. Q., Booth, K., & Zhang, L. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2829174 · Cited by 155
Abu-Siada, A., Budiri, J., & Abdou, A. (2018) · Electronics · doi:10.3390/electronics7110298 · Cited by 69
“A major advantage of multi-stage topologies is the inclusion of a l w voltage DC link as reported in [30,33,39,40] in which DC load , distributed generators, and energy storage d vices can be directly connected to the SST without the need for an AC conversion stage.”
BackgroundMethodInfluentialPower Electronics for Grid-Scale Energy Storage
Grainger, B. M., Reed, G. F., Sparacino, A. R., & Lewis, P. T. (2014) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2319819 · Cited by 64
“) [21], and General Electric (GE, Fairfield, CT, USA) [22].”
Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies
Wang, X., Liu, J., Ouyang, S., & Meng, F. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2331701 · Cited by 37
Zhu, Q., Wang, L., Chen, D., Zhang, L., & Huang, A. Q. (2017) · 2017 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8095938 · Cited by 32
“Different power conversion topologies and applications of SST family have been implemented and presented [1-12].”
BackgroundMethodDetails and implementation of a SiC-based solid state transformer prototype
Ramirez, J. M., Barrios, R. A., & Salome, B. J. (2017) · 2017 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America) · doi:10.1109/isgt-la.2017.8126690 · Cited by 6
“3kV grids and the third one is for LV grid connection [11]; (viii) ABB is currently applying SSTs for traction.”
Method
Metadata
- Authors
- Bifaretti, S., Zanchetta, P., Watson, A., Tarisciotti, L., & Clare, J. C.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2011-06
- Volume
- 2
- Issue
- 2
- Pages
- 231-243
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2127499524
- Cited by
- 339
- References
- 13
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.