Experimental Evaluation of Frequency Regulation From Commercial Building HVAC Systems
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Automated demand response can be a valuable resource for ancillary services in the power grid. This paper illustrates this value with the first experimental demonstration of frequency regulation from commercial building heating ventilation and air conditioning (HVAC) systems. The experiments were conducted in Pugh Hall, a 40000 sq. ft. commercial building located at the University of Florida. Detailed are the steps required to make this possible, including control architecture, system identification, and control design. Experiments demonstrate: that satisfactory frequency regulation service can be provided by the HVAC system without noticeable effect on the indoor climate, and the ancillary service provided by this system passes the qualification criteria for participating in the Pennsylvania-New Jersey-Maryland (PJM) interconnection's frequency regulation market.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
System identification—Theory for the user
Sinha, N. K. (1989) · Automatica · doi:10.1016/0005-1098(89)90019-8 · Cited by 9,184
An Evaluation of the HVAC Load Potential for Providing Load Balancing Service
Lu, N. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2183649 · Cited by 739 · cited 1×
“Recent research have shown that the demand side is capable of providing abundant high quality ancillary services, see [5]–[7].”
BackgroundWestern Wind and Solar Integration Study Phase 2
Lew, D. J., USDOE Office of Energy Efficiency and Renewable Energy (EERE), Brinkman, G., Ibanez, E., Florita, A. R., Heaney, M. D., Hodge, B., Hummon, M., Stark, G., King, J., et al. (2013) · doi:10.2172/1095399 · Cited by 293 · cited 1×
“Ramping of generation output also has cost in the form of additional pollution [4].”
BackgroundAncillary Service to the Grid Through Control of Fans in Commercial Building HVAC Systems
Hao, H., Lin, Y., Kowli, A. S., Barooah, P., & Meyn, S. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2322604 · Cited by 273 · cited 1×
“This paper is inspired by our prior, simulation-based, studies on using HVAC fans to provide frequency regulation [7], [14], [16].”
MethodSelf-citationLu, N., & Zhang, Y. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2222944 · Cited by 265
Occupancy-based zone-climate control for energy-efficient buildings: Complexity vs. performance
Goyal, S., Ingley, H. A., & Barooah, P. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.01.039 · Cited by 225 · cited 1×
“2) Indoor Climate: Indoor climate quality is quantified using the temperature violation DT defined in [23].”
MethodSelf-citationThe Western Wind and Solar Integration Study Phase 2
USDOE Office of Energy Efficiency and Renewable Energy (EERE), R. P. O. W. E. T. O., Lew, D. J., Brinkman, G., Ibanez, E., Florita, A. R., Heaney, M. D., Hodge, B.-M., Hummon, M., Stark, G., King, J., et al. (2013) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1220243 · Cited by 151
How demand response from commercial buildings will provide the regulation needs of the grid
Hao, H., Middelkoop, T., Barooah, P., & Meyn, S. (2012) · Allerton Conference on Communication, Control, and Computing · doi:10.1109/allerton.2012.6483455 · Cited by 120 · cited 2×
“This paper is inspired by our prior, simulation-based, studies on using HVAC fans to provide frequency regulation [7], [14], [16].”
BackgroundMethodSelf-citationAncillary service for the grid via control of commercial building HVAC systems
Hao, H., Kowli, A. S., Lin, Y., Barooah, P., & Meyn, S. (2013) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2013.6579881 · Cited by 98 · cited 1×
“The fan command uf is measured in the unit of percentage of the maximum speed.”
Self-citation
Cited by
Day-ahead building-level load forecasts using deep learning vs. traditional time-series techniques
Cai, M., Pipattanasomporn, M., & Rahman, S. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.042 · Cited by 475
Akram, U., Nadarajah, M., Shah, R., & Milano, F. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109626 · Cited by 351
Tang, H., Wang, S., & Li, H. (2021) · Energy · doi:10.1016/j.energy.2020.119598 · Cited by 259
Optimal Coordination of Building Loads and Energy Storage for Power Grid and End User Services
Hao, H., Wu, D., Lian, J., & Yang, T. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2655083 · Cited by 203
Kanellopoulos, D., Sharma, V. K., Panagiotakopoulos, T., & Kameas, A. (2023) · Electronics · doi:10.3390/electronics12112490 · Cited by 120
Metadata
- Authors
- Lin, Y., Barooah, P., Meyn, S., & Middelkoop, T.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2015-03
- Volume
- 6
- Issue
- 2
- Pages
- 776-783
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2001721531
- Cited by
- 248
- References
- 15
- FWCI
- 16.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.