The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Detecting False Data Injection Attacks in AC State Estimation
Abstract
Estimating power system states accurately is crucial to the reliable operation of power grids. Traditional weighted least square (WLS) state estimation methods face the rising threat of cyber-attacks, such as false data injection attacks, which can pass the bad data detection process in WLS state estimation. In this paper, we propose a new detection method to detect false data injection attacks by tracking the dynamics of measurement variations. The Kullback-Leibler distance (KLD) is used to calculate the distance between two probability distributions derived from measurement variations. When false data are injected into the power systems, the probability distributions of the measurement variations will deviate from the historical data, thus leading to a larger KLD. The proposed method is tested on IEEE 14 bus system using load data from the New York independent system operator with different attack scenarios. We have also tested our method on false data injection attacks that replace current measurement data with historical measurement data. Test results show that the proposed approach can accurately detect most of the attacks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2001) · Wiley eBooks · doi:10.1002/0471200611 · Cited by 36,808
Abur, A., & Expósito, A. G. (2004) · CRC Press eBooks · doi:10.1201/9780203913673 · Cited by 2,974
False data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2009) · Proceedings of the 16th ACM conference on Computer and communications security · doi:10.1145/1653662.1653666 · Cited by 1,285
Cyber–Physical System Security for the Electric Power Grid
Sridhar, S., Hahn, A., & Govindarasu, M. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165269 · Cited by 1,208
Wavelet-based texture retrieval using generalized Gaussian density and Kullback-Leibler distance
Do, M. N., & Vetterli, M. (2002) · IEEE Transactions on Image Processing · doi:10.1109/83.982822 · Cited by 1,147
State Estimation in Electric Power Systems
Monticelli, A. (1999) · Springer eBooks · doi:10.1007/978-1-4615-4999-4 · Cited by 713
State Estimation in Electric Power Systems: A Generalized Approach
Monticelli, A. (2011) · Cited by 642
Vulnerability Assessment of AC State Estimation With Respect to False Data Injection Cyber-Attacks
Hug, G., & Giampapa, J. A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2195338 · Cited by 595 · cited 2×
“Reference [8] expands the dc false data injection into ac false data injection.”
BackgroundVulnerability Assessment of Cybersecurity for SCADA Systems
Ten, C.-W., Liu, C.-C., & Manimaran, G. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2002298 · Cited by 583
Detecting False Data Injection Attacks on DC State Estimation
Bobba, R. B., Rogers, K. M., Wang, Q., Khurana, H., Nahrstedt, K., & Overbye, T. J. (2010) · Cited by 448
Detecting False Data Injection Attacks on Power Grid by Sparse Optimization
Liu, L., Esmalifalak, M., Ding, Q., Emesih, V. A., & Han, Z. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2284438 · Cited by 446
On False Data-Injection Attacks against Power System State Estimation: Modeling and Countermeasures
Yang, Q., Yang, J., Yu, W., An, D., Zhang, N., & Zhao, W. (2014) · IEEE Transactions on Parallel and Distributed Systems · doi:10.1109/tpds.2013.92 · Cited by 404
Limiting false data attacks on power system state estimation
Kosut, O., Jia, L., Thomas, R. J., & Tong, L. (2010) · Conference on Information Sciences and Systems · doi:10.1109/ciss.2010.5464816 · Cited by 167
Liu, C., Stefanov, A. I., Hong, J., & Panciatici, P. (2011) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2011.943114 · Cited by 113
Defending mechanisms against false-data injection attacks in the power system state estimation
Bi, S., & Zhang, Y. A. (2011) · IEEE Globecom Workshops (GC Wkshps) · doi:10.1109/glocomw.2011.6162362 · Cited by 100
Learning States and Rules for Time Series Anomaly Detection.
Salvador, S., Chan, P. K., & Brodie, J. (2004) · Cited by 77
On malicious data attacks on power system state estimation
Kosut, O., Jia, L., Thomas, R. J., & Tong, L. (2010) · Cited by 73
Symbolic time-series analysis for anomaly detection in mechanical systems
Khatkhate, A. M., Ray, A., Keller, E., Gupta, S., & Chin, S. C. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.878544 · Cited by 43
Tong, S., Li, Z., Zhu, Y., & Thakor, N. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893497 · Cited by 38
A novel architecture against false data injection attacks in smart grid
Bhattarai, S., Ge, L., & Yu, W. (2012) · International Conference on Communications · doi:10.1109/icc.2012.6364511 · Cited by 27
Generalized Time-Series Active Search With Kullback–Leibler Distance for Audio Fingerprinting
Lin, H., Ou, Z., & Xiao, X. (2006) · IEEE Signal Processing Letters · doi:10.1109/lsp.2006.874394 · Cited by 7
Cited by
A Review of False Data Injection Attacks Against Modern Power Systems
Liang, G., Zhao, J., Luo, F., Weller, S. R., & Dong, Z. Y. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2495133 · Cited by 1,028
A Survey on the Detection Algorithms for False Data Injection Attacks in Smart Grids
Musleh, A. S., Chen, G., & Dong, Z. Y. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2949998 · Cited by 714
Online False Data Injection Attack Detection With Wavelet Transform and Deep Neural Networks
Yu, J. J. Q., Hou, Y., & Li, V. O. K. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2825243 · Cited by 378
Blockchain Applications in Smart Grid–Review and Frameworks
Musleh, A. S., Yao, G., & Muyeen, S. M. (2019) · IEEE Access · doi:10.1109/access.2019.2920682 · Cited by 342
Detecting False Data Injection Attacks in Smart Grids: A Semi-Supervised Deep Learning Approach
Zhang, Y., Wang, J., & Chen, B. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.3010510 · Cited by 332
Metadata
- Authors
- Chaojun, G., Jirutitijaroen, P., & Motani, M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2015-09
- Volume
- 6
- Issue
- 5
- Pages
- 2476-2483
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2093197140
- Cited by
- 419
- References
- 21
- FWCI
- 21.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.