Relay Protection Coordination Integrated Optimal Placement and Sizing of Distributed Generation Sources in Distribution Networks
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The integration of distributed generation (DG) sources can cause significant impacts on distribution networks, particularly the changes in magnitudes and directions of short circuit currents that may lead to false tripping or fail to trip over-current protection relays in the system. It is expensive and technically challenging to redesign/reconfigure and/or to replace the original protection system for a distribution network. If not appropriately handled, this issue can be a big hurdle before the wide use of DG. Based on the impact analysis of the number of DGs, their locations and capacities upon short circuit currents, this paper presents an optimal DG placement method to maximize the penetration level of DG in distribution networks without changing the original relay protection schemes. Genetic algorithm is used to find the optimal locations and sizes of DG in distribution networks. Simulation studies have been carried out on a three-feeder test distribution network and a widely used 33-node test system to show the effectiveness of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Network reconfiguration in distribution systems for loss reduction and load balancing
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.25627 · Cited by 5,077 · cited 2×
“The 33-node test system [26], shown in Fig.”
MethodNetwork Reconfiguration in Distribution Systems for Loss Reduction and Load Balancing
Baran, M. E., & Wu, F. F. (1989) · IEEE Power Engineering Review · doi:10.1109/mper.1989.4310642 · Cited by 3,350
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107 · cited 1×
“On the one hand, some power electronic inverters are designed to mimic synchronous generators so that wellestablished methods (such as frequency droop and voltage droop control) for synchronous generators can be used for controlling power electronic-based DG sources [27].”
BackgroundAnalytical Approaches for Optimal Placement of Distributed Generation Sources in Power Systems
Wang, C., & Nehrir, M. H. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.836189 · Cited by 1,209
Self-citationSaadat, H. (1998) · CERN Document Server (European Organization for Nuclear Research) · Cited by 1,033
Rao, R. S., Ravindra, K., Satish, K., & Narasimham, S. V. L. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2197227 · Cited by 1,023
Georgilakis, P. S., & Hatziargyriou, N. D. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2237043 · Cited by 875 · cited 2×
“Nevertheless, little effort has been carried out on the optimal placement of DGs while considering the relay protection, which is also evidenced by the comprehensive survey papers [13], [14].”
BackgroundMultiple Distributed Generator Placement in Primary Distribution Networks for Loss Reduction
Hung, D. Q., & Mithulananthan, N. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2112316 · Cited by 794
The parallel genetic algorithm as function optimizer
Mühlenbein, H., Schomisch, M., & Born, J. (1991) · Parallel Computing · doi:10.1016/s0167-8191(05)80052-3 · Cited by 782 · cited 1×
“GA can be used to handle the optimization of numerous individuals in a group at the same time by using selection, crossover, and mutation operations to search for the optimal solution in the solution space [30].”
MethodBrahma, S. M., & Girgis, A. A. (2004) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.820204 · Cited by 679
Cited by
State-of-the-art of hosting capacity in modern power systems with distributed generation
Ismael, S. M., Abdel Aleem, S. H. E., Abdelaziz, A. Y., & Zobaa, A. F. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.07.008 · Cited by 599
Central Power Research Institute, Telukunta, V., Pradhan, J., Central Power Research Institute, Agrawal, A., Central Power Research Institute, Singh, M., Central Power Research Institute, Srivani, S. G., & R V College of Engineering (2017) · CSEE Journal of Power and Energy Systems · doi:10.17775/cseejpes.2017.00030 · Cited by 544
Metadata
- Authors
- Zhan, H., Wang, C., Wang, Y., Yang, X., Zhang, X., Wu, C., & Chen, Y.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2016-01
- Volume
- 7
- Issue
- 1
- Pages
- 55-65
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2062286591
- Cited by
- 194
- References
- 22
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relay Protection Coordination Integrated Optimal Placement and Sizing of Distributed Generation Sources in Distribution Networks. https://app.cochat.ai/papers/10.1109/tsg.2015.2420667
- The paper
- Zhan, H., Wang, C., Wang, Y., Yang, X., Zhang, X., Wu, C., & Chen, Y. (2016). Relay Protection Coordination Integrated Optimal Placement and Sizing of Distributed Generation Sources in Distribution Networks. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2015.2420667
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.