CoChat

Relay Protection Coordination Integrated Optimal Placement and Sizing of Distributed Generation Sources in Distribution Networks

Zhan, Hongxia, Wang, Caisheng, Wang, Yang, Yang, Xiaohua, Zhang, Xi, Wu, Changjiang, Chen, Yihuai · 2016 · IEEE Transactions on Smart Grid
Cited by 194

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

The integration of distributed generation (DG) sources can cause significant impacts on distribution networks, particularly the changes in magnitudes and directions of short circuit currents that may lead to false tripping or fail to trip over-current protection relays in the system. It is expensive and technically challenging to redesign/reconfigure and/or to replace the original protection system for a distribution network. If not appropriately handled, this issue can be a big hurdle before the wide use of DG. Based on the impact analysis of the number of DGs, their locations and capacities upon short circuit currents, this paper presents an optimal DG placement method to maximize the penetration level of DG in distribution networks without changing the original relay protection schemes. Genetic algorithm is used to find the optimal locations and sizes of DG in distribution networks. Simulation studies have been carried out on a three-feeder test distribution network and a widely used 33-node test system to show the effectiveness of the proposed method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tsg.2015.2420667

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 194

Metadata

Authors
Zhan, H., Wang, C., Wang, Y., Yang, X., Zhang, X., Wu, C., & Chen, Y.
Venue
IEEE Transactions on Smart Grid
Published
2016-01
Volume
7
Issue
1
Pages
55-65
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W2062286591
Cited by
194
References
22
FWCI
6.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.