Pulse-Width-Modulation-Based Electromagnetic Interference Mitigation of Bidirectional Grid-Connected Converters for Electric Vehicles
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
This paper proposes a new pulse-width-modulation (PWM) technique for the electromagnetic interference (EMI) mitigation of the bidirectional grid-connected converter, which is aiming to improve the power quality of power grids and the working environment of electric vehicles (EVs), as well as the implementability especially for high-frequency applications. Due to the frequent energy exchange in vehicle-to-grid (V2G) systems, the EV electromagnetic environment becomes increasingly complex, which may impair the normal operation of various auxiliary electronic devices and hence reduce the stability of EVs. Additionally, the conducted EMI deteriorates the power supply quality in the power grid. In this paper, a PWM-based EMI mitigation technique is proposed for the bidirectional grid-connected converter to suppress exaggerated peaky EMI and evenly distribute the harmonics over a wide frequency range, thereby improving the electromagnetic compatibility of the grid-connected converter. Also, the simulation and experiment are both conducted to illustrate the effectiveness of the proposed PWM-based EMI mitigation technique for the V2G bidirectional grid-connected power converter.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Integration of electric vehicles in the electric power system
Lopes, J. A. P., Soares, F. J., & Almeida, P. M. R. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2066250 · Cited by 1,465 · cited 1×
“GRID-CONNECTED power converter offers the electric vehicle (EV) the ability of exchanging the energy with the power grid, which can alleviate the peak load in the power system [1], [2].”
BackgroundModern Electric Vehicle Technology
Chan, C. C., & Chau, K. T. (2001) · doi:10.1093/oso/9780198504160.001.0001 · Cited by 572
Self-citationConducted EMI Mitigation Techniques for Switch-Mode Power Converters: A Survey
Mainali, K., & Oruganti, R. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2047734 · Cited by 356
Optimal Energy Management for a Residential Microgrid Including a Vehicle-to-Grid System
Igualada, L., Corchero, C., Cruz-Zambrano, M., & Heredia, F.-J. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2318836 · Cited by 285 · cited 1×
“2541163 is also important for improving the power quality of the power system [3], [4].”
BackgroundCapacity Estimation for Vehicle-to-Grid Frequency Regulation Services With Smart Charging Mechanism
Lam, A. Y. S., Leung, K.-C., & Li, V. O. K. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2436901 · Cited by 203 · cited 2×
“2541163 is also important for improving the power quality of the power system [3], [4].”
BackgroundHu, J., & Zhu, Z. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2194512 · Cited by 170 · cited 1×
“energies [15], [16].”
Generalization of active filters for EMI reduction and harmonics compensation
Son, Y.-C., & Sul, S. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.870030 · Cited by 168
Hopf bifurcation and chaos in a free-running current-controlled Cuk switching regulator
Tse, C. K., Lai, Y. M., & Iu, H. H. (2000) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/81.841847 · Cited by 140
Tani, A., Camara, M. B., Dakyo, B., & Azzouz, Y. (2012) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2225632 · Cited by 121
Bifurcation behavior in parallel-connected buck converters
Iu, H. H., & Tse, C. K. (2001) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/81.904890 · Cited by 118
A Novel EMI Filter Design Method for Switching Power Supplies
Ye, S., Eberle, W., & Liu, Y.-F. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836629 · Cited by 116 · cited 1×
“An active filter was designed to compensate the signal by detecting the noise source [8], while a passive EMI filter was designed based on the maximum or minimum estimated amplitudes of the noise source impedances [9].”
MethodKaboli, S., Mahdavi, J., & Agah, A. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899944 · Cited by 106 · cited 1×
“In [12], a random pulse-width-modulation (PWM) was proposed to suppress the EMI in active filters based on the”
MethodEMI Noise Control Methods Suitable for Electric Vehicle Drive Systems
Mutoh, N., Nakanishi, M., Kanesaki, M., & Nakashima, J. (2005) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2005.857893 · Cited by 98 · cited 6×
“However, it is still a vacant research area to the EMI mitigation technique for the bidirectional grid-connected power converter from the perspective of the synthesized impact on EVs and smart grids.”
BackgroundInfluentialPareschi, F., Setti, G., Rovatti, R., & Frattini, G. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2286258 · Cited by 97 · cited 1×
“In [11], a reliable mathematical model was developed as a spectrum analyzer for the spread spectrum clocking method adopted in the suppression”
MethodSuppressing electromagnetic interference in direct current converters
Li, H., Li, Z., Zhang, B., Tang, K. S., & Halang, W. A. (2009) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2009.934705 · Cited by 94 · cited 1×
“sequence [24]–[26].”
Design of Analogue Chaotic PWM for EMI Suppression
Li, H., Li, Z., Zhang, B., Wang, F., Tan, N., & Halang, W. A. (2010) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2010.2071878 · Cited by 83 · cited 1×
“Based on the random-like-but-bounded characteristic of the chaos, the Chua’s circuit was then utilized to produce chaotic signals to improve the PWM scheme [13].”
MethodA Unified Single- and Three-Phase Control for Grid Connected Electric Vehicles
Arancibia, A., Strunz, K., & Mancilla–David, F. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2271096 · Cited by 68 · cited 1×
“1 depicts the topology of the bidirectional grid-connected power converter, which is composed of a single-phase AC/DC converter and a bidirectional DC/DC converter [17], [18].”
BackgroundEMI reduction by interleaving of power converters
Zumel, P., García, O., Cobos, J. A., & Uceda, J. (2004) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2004.1295894 · Cited by 57 · cited 1×
“A boost converter with anti-phase winding was proposed to compensate the voltage with the same amplitude and opposite polarity for the common-mode (CM) noise caused by the voltage variation [7].”
BackgroundHigh-Frequency Behavioral Multiconductor Cable Modeling for EMI Simulations in Power Electronics
Stevanović, I., Wunsch, B., Madonna, G. L., & Skibin, S. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2307198 · Cited by 48
Sumner, M., Abusorrah, A. M., Thomas, D., & Zanchetta, P. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2298495 · Cited by 44 · cited 1×
“energies [15], [16].”
Zhang, Z., Chau, K. T., Wang, Z., & Li, W. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2152371 · Cited by 43 · cited 1×
“Besides, a hybrid chaotic PWM algorithm was proposed and implemented to suppress the peaky EMI and reduce the occurrence of low-order noises for AC motor drives, where the carrier frequency and the pulse position were simultaneously regulated in a chaotic way [14].”
MethodSelf-citationAC/DC/DC Interfaces for V2G Applications—EMC Issues
Smoleński, R., Jarnut, M., Benysek, G., & Kempski, A. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188876 · Cited by 42 · cited 1×
“This phenomenon was also discussed and verified by an experiment in [20], namely the EMI induced by the power”
MethodStemmler, H., & Eilinger, T. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1994.349721 · Cited by 40 · cited 1×
“for the conducted EMI issue, the corresponding output AC voltage can be obtained expressed as [23]:”
BackgroundElrayyah, A. Y., Namburi, K. M., Sozer, Y., & Husain, I. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2277665 · Cited by 38 · cited 1×
“By adopting the periodic dithering of pulse-width-modulation (PWM) switching frequency, a comprehensive EMI reduction scheme was proposed for DC/AC inverters [10].”
MethodImpact of Switching-Induced Electromagnetic Interference on Low-Voltage Cables in Substations
Heydari, H., Abbasi, V., & Faghihi, F. (2009) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2009.2028236 · Cited by 38 · cited 1×
“On the other hand, the conducted EMI issue also deteriorates the electromagnetic environment of EVs [21], [22].”
BackgroundPower electronics interfaces for low voltage distribution generation — EMC issues
Smoleński, R., Jarnut, M., Benysek, G., & Kempski, A. (2011) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe.2011.5942216 · Cited by 10 · cited 1×
“In [19], a high level of EMI was generated in power converters of the low-voltage (LV) grid, resulting in an increasing”
Background
Cited by
Topologies and Control Schemes of Bidirectional DC–DC Power Converters: An Overview
Gorji, S. A., Sahebi, H. G., Ektesabi, M., & Rad, A. B. (2019) · IEEE Access · doi:10.1109/access.2019.2937239 · Cited by 439
“As such, these converters are flexible and are widely used in electric vehicles (EVs) or hybrid electric vehicles (HEVs) [1], smart grids [2], uninterruptable power supplies (UPS) [3], aerospace applications [4] and renewable energy systems such as photovoltaic (PV) arrays, fuel cells (FCs), and wind turbines [5]–[7].”
BackgroundZografopoulos, I., Hatziargyriou, N. D., & Konstantinou, C. (2023) · IEEE Systems Journal · doi:10.1109/jsyst.2023.3305757 · Cited by 173
“For instance, the authors in [114] and [115], propose pulse-width-modulation and a high-frequency resonance scheme, respectively, that can mitigate the power quality degradation introduced by EVs and bidirectional gridtied converters (e.”
BackgroundTang, Y., Hu, W., Xiao, J. Q., Chen, Z., Huang, Q., Chen, Z., & Blaabjerg, F. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3007113 · Cited by 164
“As one of the most popular bidirectional topologies, the DAB DC-DC converter is widely used in electric vehicles (EVs), smart grids and renewable energy systems [2]-[4], etc.”
BackgroundXu, X., Mi, J., Fan, M., Yang, K., Wang, H., Liu, J., & Yan, H. (2018) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2018.12.262 · Cited by 97
Xu, X., Hui, K. S., Hui, K. N., Wang, H., & Liu, J. (2020) · Materials Horizons · doi:10.1039/c9mh01701a · Cited by 69
Metadata
- Authors
- Zhang, Z., & Chau, K.-T.
- Affiliations
- Tianjin University (CN)
- University of Hong Kong (HK)
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2017-11
- Volume
- 8
- Issue
- 6
- Pages
- 2803-2812
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2317555270
- Cited by
- 47
- References
- 26
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 5 · 2023: 8 · 2022: 8 · 2021: 3 · 2020: 6 · 2019: 3 · 2018: 4 · 2017: 2
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Smart Grid (publishedVersion)
- Funders
- University of Hong Kong, Hong Kong (SPF 201309176048, SPF 201409176172)
- Basic Research Program of Science, Technology, and Innovation Commission of Shenzhen Municipality, Shenzhen, China (JCYJ20120831142942515)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- pulse width modulation, electromagnetic interference suppression, electric vehicles, vehicle-to-grid, conducted emissions, harmonic distribution, power quality, electromagnetic compatibility
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.