Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography
Abstract
This paper describes a new technique for two-dimensional (2-D) imaging of the motion vector at a very high frame rate with ultrasound. Its potential is experimentally demonstrated for transient elastography. But, beyond this application, it also could be promising for color flow and reflectivity imaging. To date, only axial displacements induced in human tissues by low-frequency vibrators were measured during transient elastography. The proposed technique allows us to follow both axial and lateral displacements during the shear wave propagation and thus should improve Young's modulus image reconstruction. The process is a combination of several ideas well-known in ultrasonic imaging: ultra-fast imaging, multisynthetic aperture beamforming, 1-D speckle tracking, and compound imaging. Classical beamforming in the transmit mode is replaced here by a single plane wave insonification increasing the frame rate by at least a factor of 128. The beamforming is achieved only in the receive mode on two independent subapertures. Comparison of successive frames by a classical 1-D speckle tracking algorithm allows estimation of displacements along two different directions linked to the subapertures beams. The variance of the estimates is finally improved by tilting the emitting plane wave at each insonification, thus allowing reception of successive decorrelated speckle patterns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
“Sonoelasticity” images derived from ultrasound signals in mechanically vibrated tissues
Lerner, R. M., Huang, S. R., & Parker, K. J. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90002-t · Cited by 493
Ultrasonic imaging of internal vibration of soft tissue under forced vibration
Yamakoshi, Y., Sato, J., & Sato, T. (1990) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.46969 · Cited by 474
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
A new method for estimation of velocity vectors
Jensen, J. A., & Munk, P. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.677749 · Cited by 428
Shear elasticity probe for soft tissues with 1-D transient elastography
Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996561 · Cited by 427
Self-citationShear modulus imaging with 2-D transient elastography
Sandrin, L., Tanter, M., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996560 · Cited by 412
Self-citationHein, I. A., & O'Brien, W. D. (1993) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.212556 · Cited by 309
A solution to diffraction biases in sonoelasticity: The acoustic impulse technique
Catheline, S., Wu, F., & Fink, M. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426907 · Cited by 282
Self-citationTime-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging
Sandrin, L., Catheline, S., Tanter, M., Hennequin, X., & Fink, M. (1999) · Ultrasonic Imaging · doi:10.1177/016173469902100402 · Cited by 267
Self-citationLerner, R. M., Parker, K. J., Holen, J., Gramiak, R., & Waag, R. C. (1988) · Acoustical Imaging · doi:10.1007/978-1-4613-0725-9_31 · Cited by 220
Jespersen, S. K., Wilhjelm, J. E., & Sillesen, H. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000201 · Cited by 205
Measurement of soft tissue motion using correlation between A-scans
Dickinson, R. J., & Hill, C. R. (1982) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(82)90032-1 · Cited by 186
Multiple crossed-beam ultrasound Doppler velocimetry
Fox, M. D. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.31028 · Cited by 172
Multi-dimensional velocity estimation with ultrasound using spatial quadrature
Aderson, M. E. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.677757 · Cited by 171
Ultrasound Doppler Probing of Flows Transverse with Respect to Beam Axis
Newhouse, V. L., Censor, D., Vontz, T., Cisneros, J. A., & Goldberg, B. B. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325920 · Cited by 170
Diffraction field of a low frequency vibrator in soft tissues using transient elastography
Catheline, S., Thomas, J.-L., Wu, F., & Fink, M. A. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.775668 · Cited by 167
Self-citationCéspedes, I., Ophir, J., & Alam, S. K. (1997) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.585223 · Cited by 96
A New Velocity Estimator for Color Flow Mapping
Bonnefous, O., Pesque, P., & Bernard, X. (1986) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1986.198856 · Cited by 60
A real-time two-dimensional pulsed-wave Doppler system
Scabia, M., Calzolai, M., Capineri, L., Masotti, L. F., & Fort, A. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00115-5 · Cited by 35
Acoustic shear wave displacement measurement using ultrasound
Dutt, V., Kinnick, R. R., & Greenleaf, J. F. (2002) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1996.584202 · Cited by 25
Cited by
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Self-citationCoherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814
Self-citationUltrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Self-citationDemene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Self-citation
Metadata
- Authors
- Tanter, M., Bercoff, J., Sandrin, L., & Fink, M.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2002-10
- Volume
- 49
- Issue
- 10
- Pages
- 1363-1374
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2142012261
- Cited by
- 414
- References
- 21
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.