Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Frequency Comparison of $^{171}{\text {Yb}}^+$ Ion Optical Clocks at PTB and NPL via GPS PPP

Leute, J., Huntemann, N., Lipphardt, B., Tamm, Christian, Nisbet-Jones, P. B. R., King, S. A., Godun, R. M., Jones, J. M., Margolis, H. S., Whibberley, P. B., Wallin, A., Merimaa, M., Gill, P., Peik, E. · 2016 · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

Abstract

We used precise point positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled [Formula: see text] ions operated at the National Physical Laboratory (NPL), U.K. and the Physikalisch-Technische Bundesanstalt (PTB), Germany. At both institutes, an active hydrogen maser serves as a flywheel oscillator which is connected to a GPS receiver as an external frequency reference and compared simultaneously to a realization of the unperturbed frequency of the (2)S1/2(F=0)-(2)D3/2(F=2) electric quadrupole transition in [Formula: see text] via an optical femtosecond frequency comb. To profit from long coherent GPS-link measurements, we extrapolate the fractional frequency difference over the various data gaps in the optical clock to maser comparisons which introduces maser noise to the frequency comparison but improves the uncertainty from the GPS-link instability. We determined the total statistical uncertainty consisting of the GPS-link uncertainty and the extrapolation uncertainties for several extrapolation schemes. Using the extrapolation scheme with the smallest combined uncertainty, we find a fractional frequency difference [Formula: see text] of -1.3×10(-15) with a combined uncertainty of 1.2×10(-15) for a total measurement time of 67 h. This result is consistent with an agreement of the frequencies realized by both optical clocks and with recent absolute freque…

Overview

Integrity signals

Registry

Crossref · 10.1109/tuffc.2016.2524988

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 35

Metadata

Authors
Leute, J., Huntemann, N., Lipphardt, B., Tamm, C., Nisbet-Jones, P. B. R., King, S. A., Godun, R. M., Jones, J. M., Margolis, H. S., Whibberley, P. B., Wallin, A., Merimaa, M., Gill, P., & Peik, E.
Affiliations
  • Physikalisch-Technische Bundesanstalt (DE)
  • National Physical Laboratory (GB)
  • National metrology institute VTT MIKES (FI)
Venue
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Published
2016-07
Volume
63
Issue
7
Pages
981-985
ISSN
0885-3010 (ISSN-L)
OpenAlex
W2964181237
Cited by
29
References
18
Citations by year
2026: 1 · 2025: 3 · 2024: 1 · 2023: 5 · 2022: 4 · 2021: 1 · 2020: 4 · 2019: 2 · 2018: 4 · 2017: 3 · 2016: 1
FWCI
1.58
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control (publishedVersion)
  • PubMed (publishedVersion)
Funders
EMRP (SIB04)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
Keywords
171Yb, precise point positioning, femtosecond optical frequency comb, E2 transitions, extrapolation uncertainty, absolute frequency measurement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.