The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Airborne transmission of severe acute respiratory syndrome coronavirus‐2 to healthcare workers: a narrative review
Open accessAbstract
Summary: Healthcare workers are at risk of infection during the severe acute respiratory syndrome coronavirus‐2 pandemic. International guidance suggests direct droplet transmission is likely and airborne transmission occurs only with aerosol‐generating procedures. Recommendations determining infection control measures to ensure healthcare worker safety follow these presumptions. Three mechanisms have been described for the production of smaller sized respiratory particles (‘aerosols’) that, if inhaled, can deposit in the distal airways. These include: laryngeal activity such as talking and coughing; high velocity gas flow; and cyclical opening and closure of terminal airways. Sneezing and coughing are effective aerosol generators, but all forms of expiration produce particles across a range of sizes. The 5‐μm diameter threshold used to differentiate droplet from airborne is an over‐simplification of multiple complex, poorly understood biological and physical variables. The evidence defining aerosol‐generating procedures comes largely from low‐quality case and cohort studies where the exact mode of transmission is unknown as aerosol production was never quantified. We propose that transmission is associated with time in proximity to severe acute respiratory syndrome coronavirus‐1 patients with respiratory symptoms, rather than the procedures per se. There is no proven relation between any aerosol‐generating procedure with airborne viral content with the exception of bronchoscopy and suctioning. The mechanism for severe acute respiratory syndrome coronavirus‐2 transmission is unknown but the evidence suggestive of airborne spread is growing. We speculate that infected patients who cough, have high work of breathing, increased closing capacity and altered respiratory tract lining fluid will be significant producers of pathogenic aerosols. We suggest several aerosol‐generating procedures may in fact result in less pathogen aerosolisation than a dyspnoeic and coughing patient. Healthcare workers should appraise the current evidence regarding transmission and apply this to the local infection prevalence. Measures to mitigate airborne transmission should be employed at times of risk. However, the mechanisms and risk factors for transmission are largely unconfirmed. Whilst awaiting robust evidence, a precautionary approach should be considered to assure healthcare worker safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1
van Doremalen, N., Bushmaker, T., Morris, D. H., Holbrook, M. G., Gamble, A., Williamson, B. N., Tamin, A., Harcourt, J. L., Thornburg, N. J., Gerber, S. I., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2004973 · Cited by 9,951
Hamming, I., Timens, W., Bulthuis, M., Lely, A., Navis, G., & van Goor, H. (2004) · The Journal of Pathology · doi:10.1002/path.1570 · Cited by 5,676
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
High expression of ACE2 receptor of 2019-nCoV on the epithelial cells of oral mucosa
Xu, H., Zhong, L., Deng, J., Peng, J., Dan, H., Zeng, X., Li, T., & Chen, Q. (2020) · International Journal of Oral Science · doi:10.1038/s41368-020-0074-x · Cited by 2,838
Zhang, H., Penninger, J. M., Li, Y., Zhong, N., & Slutsky, A. S. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-05985-9 · Cited by 2,684
Ong, S. W. X., Tan, Y. K., Chia, P. Y., Lee, T. H., Ng, O. T., Wong, M. S. Y., & Marimuthu, K. (2020) · JAMA · doi:10.1001/jama.2020.3227 · Cited by 2,140
Tran, K., Cimon, K., Severn, M., Pessoa-Silva, C. L., & Conly, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0035797 · Cited by 1,811
COVID-19: Gastrointestinal Manifestations and Potential Fecal–Oral Transmission
Gu, J., Han, B., & Wang, J. (2020) · Gastroenterology · doi:10.1053/j.gastro.2020.02.054 · Cited by 1,501
Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus
Yu, I. T. S., Li, Y., Wong, T. W., Tam, W., Chan, A. T., Lee, J. H. W., Leung, D. Y. C., & Ho, T. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032867 · Cited by 1,256
Bourouiba, L. (2020) · JAMA · doi:10.1001/jama.2020.4756 · Cited by 1,066
How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00469.x · Cited by 966
Cook, T. M., El‐Boghdadly, K., McGuire, B., McNarry, A. F., Patel, A., & Higgs, A. (2020) · Anaesthesia · doi:10.1111/anae.15054 · Cited by 886
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Milton, D. K., Fabian, M. P., Cowling, B. J., Grantham, M. L., & McDevitt, J. J. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003205 · Cited by 669
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
Modality of human expired aerosol size distributions
Johnson, G. R., Morawska, L., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Chao, C. Y. H., Wan, M. P., Li, Y., Xie, X., Katoshevski, D., et al. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.07.009 · Cited by 655
Roles of Humidity and Temperature in Shaping Influenza Seasonality
Lowen, A. C., & Steel, J. (2014) · Journal of Virology · doi:10.1128/jvi.03544-13 · Cited by 540
Airborne spread of infectious agents in the indoor environment
Wei, J., & Li, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.003 · Cited by 519
Booth, T. F., Kournikakis, B., Bastien, N., Ho, J., Kobasa, D., Stadnyk, L., Li, Y., Spence, M., Paton, S., Henry, B., et al. (2005) · The Journal of Infectious Diseases · doi:10.1086/429634 · Cited by 425
Human Influenza Resulting from Aerosol Inhalation
Alford, R. H., Kasel, J. A., Gerone, P. J., & Knight, V. (1966) · Experimental Biology and Medicine · doi:10.3181/00379727-122-31255 · Cited by 363
Inhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362
Aerosol transmission is an important mode of influenza A virus spread
Cowling, B. J., Ip, D. K. M., Fang, V. J., Suntarattiwong, P., Olsen, S. J., Levy, J., Uyeki, T. M., Leung, G. M., Malik Peiris, J. S., Chotpitayasunondh, T., et al. (2013) · Nature Communications · doi:10.1038/ncomms2922 · Cited by 346
SARS among Critical Care Nurses, Toronto
Loeb, M., McGeer, A., Henry, B., Ofner, M., Rose, D., Hlywka, T., Levie, J., McQueen, J., Smith, S., Moss, L., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030838 · Cited by 345
Measurement of Airborne Influenza Virus in a Hospital Emergency Department
Blachere, F. M., Lindsley, W. G., Pearce, T. A., Anderson, S. E., Fisher, M., Khakoo, R., Meade, B. J., Lander, O., Davis, S., Thewlis, R. E., et al. (2009) · Clinical Infectious Diseases · doi:10.1086/596478 · Cited by 342
Exhaled air dispersion during high-flow nasal cannula therapy versus CPAP via different masks
Hui, D. S., Chow, B. K., Lo, T., Tsang, O. T. Y., Ko, F. W., Ng, S. S., Gin, T., & Chan, M. T. V. (2019) · European Respiratory Journal · doi:10.1183/13993003.02339-2018 · Cited by 328
Lindsley, W. G., Pearce, T. A., Hudnall, J. B., Davis, K. A., Davis, S. M., Fisher, M. A., Khakoo, R., Palmer, J. E., Clark, K. E., Celik, I., et al. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.684582 · Cited by 300
Transmission of Severe Acute Respiratory Syndrome during Intubation and Mechanical Ventilation
Fowler, R. A., Guest, C. B., Lapinsky, S. E., Sibbald, W. J., Louie, M., Tang, P., Simor, A. E., & Stewart, T. E. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200305-715oc · Cited by 295
Possible SARS Coronavirus Transmission during Cardiopulmonary Resuscitation
Christian, M. D., Loutfy, M., McDonald, L. C., Martinez, K. F., Ofner, M., Wong, T., Wallington, T., Gold, W. L., Mederski, B., Green, K., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030700 · Cited by 274
Cluster of SARS among Medical Students Exposed to Single Patient, Hong Kong
Wong, T.-W., Lee, C.-K., Tam, W., Lau, J. T.-F., Yu, T.-S., Lui, S.-F., Chan, P. K. S., Li, Y., Bresee, J. S., Sung, J. J. Y., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030452 · Cited by 265
Yang, W., Elankumaran, S., & Marr, L. C. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0686 · Cited by 260 · cited 1×
“The airborne viral content was calculated to be in excess of the minimal infectious dose [40].”
BackgroundWang, K., Zhao, W., Li, J., Shu, W., & Duan, J. (2020) · Annals of Intensive Care · doi:10.1186/s13613-020-00653-z · Cited by 241
Effect of airway opening on production of exhaled particles
Almstrand, A.-C., Bake, B., Ljungström, E., Larsson, P., Bredberg, A., Mirgorodskaya, E., & Olin, A.-C. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00873.2009 · Cited by 226
SARS Transmission among Hospital Workers in Hong Kong
Lau, J. T. F., Fung, K. S., Wong, T. W., Kim, J. H., Wong, E., Chung, S., Ho, D., Chan, L. Y., Lui, S. F., & Cheng, A. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1002.030534 · Cited by 224
Exhaled Particles and Small Airways
Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E., & Olin, A.-C. (2019) · Respiratory Research · doi:10.1186/s12931-019-0970-9 · Cited by 218
Influenza Virus Infectivity Is Retained in Aerosols and Droplets Independent of Relative Humidity
Kormuth, K. A., Lin, K., Prussin, A. J., Vejerano, E. P., Tiwari, A. J., Cox, S. S., Myerburg, M. M., Lakdawala, S. S., & Marr, L. C. (2018) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiy221 · Cited by 205
Cheung, T. M. T., Yam, L. Y. C., So, L. K. Y., Lau, A. C. W., Poon, E., Kong, B. M. H., & Yung, R. W. H. (2004) · Chest · doi:10.1378/chest.126.3.845 · Cited by 191
Yoshida, T., Grieco, D. L., Brochard, L. J., & Fujino, Y. (2019) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000691 · Cited by 158
Wells, W. F. (1936) · JAMA · doi:10.1001/jama.1936.02770470016004 · Cited by 151
Viable Influenza A Virus in Airborne Particles from Human Coughs
Lindsley, W. G., Noti, J. D., Blachère, F. M., Thewlis, R. E., Martin, S. B., Othumpangat, S., Noorbakhsh, B., Goldsmith, W. T., Vishnu, A., Palmer, J. E., et al. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2014.973113 · Cited by 144
Ventilatory mechanics and expiratory flow limitation during exercise in normal subjects
Ólafsson, S., & Hyatt, R. E. (1969) · Journal of Clinical Investigation · doi:10.1172/jci106015 · Cited by 134
Thompson, K., Pappachan, J., Bennett, A., Mittal, H., Macken, S., Dove, B. K., Nguyen‐Van‐Tam, J. S., Copley, V. R., O’Brien, S. J., Hoffman, P. N., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056278 · Cited by 113
Experimental Air-Borne Influenza Infection. I. Influence of Humidity on Survival of Virus in Air.
Loosli, C. G., Lemon, H. M., ROBERTSON, O. H., & Appel, E. (1943) · Experimental Biology and Medicine · doi:10.3181/00379727-53-14251p · Cited by 107
Airborne transmission and precautions: facts and myths
Seto, W. (2014) · Journal of Hospital Infection · doi:10.1016/j.jhin.2014.11.005 · Cited by 106
Exhaled Endogenous Particles Contain Lung Proteins
Bredberg, A., Gobom, J., Almstrand, A., Larsson, P., Blennow, K., Olin, A., & Mirgorodskaya, E. E. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.169235 · Cited by 97
The use of high‐flow nasal oxygen in COVID ‐19
Lyons, C., & Callaghan, M. (2020) · Anaesthesia · doi:10.1111/anae.15073 · Cited by 89
Modeling airflow-related shear stress during heterogeneous constriction and mechanical ventilation
Nucci, G., Suki, B., & Lutchen, K. R. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01179.2001 · Cited by 85
Lack of SARS Transmission among Healthcare Workers, United States
Park, B. J., Peck, A. J., Kuehnert, M. J., Newbern, E. C., Smelser, C. B., Comer, J. A., Jernigan, D. B., & McDonald, L. C. (2004) · Emerging infectious diseases · doi:10.3201/eid1002.030793 · Cited by 83
Hui, D. S. C., Chan, M. T. V., & Chow, B. (2014) · PubMed · Cited by 72
Loudon, R. G., & ROBERTS, R. M. (1967) · Nature · doi:10.1038/213095a0 · Cited by 71
Lack of SARS Transmission and U.S. SARS Case-Patient
Peck, A. J., Newbern, E. C., Feikin, D. R., Isakbaeva, E. T., Park, B. J., Fehr, J. T., LaMonte, A., Le, T. P., Burger, T. L., Rhodes, L. V., et al. (2004) · Emerging infectious diseases · doi:10.3201/eid1002.030746 · Cited by 34
Snyder, M. H., Stephenson, Ε. H., Young, H. A., York, C., Tierney, E. L., London, W. T., Chanock, R. M., & Murphy, B. R. (1986) · The Journal of Infectious Diseases · doi:10.1093/infdis/154.4.709 · Cited by 23
Cited by
SARS-CoV-2 Reverse Genetics Reveals a Variable Infection Gradient in the Respiratory Tract
Hou, Y. J., Okuda, K., Edwards, C. E., Martinez, D. R., Asakura, T., Dinnon, K. H., Kato, T., Lee, R. E., Yount, B. L., Mascenik, T. M., et al. (2020) · Cell · doi:10.1016/j.cell.2020.05.042 · Cited by 1,488
The COVID-19 puzzle: deciphering pathophysiology and phenotypes of a new disease entity
Osuchowski, M. F., Winkler, M. S., Skirecki, T., Cajander, S., Shankar-Hari, M., Lachmann, G., Monneret, G., Venet, F., Bauer, M., Brunkhorst, F. M., et al. (2021) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(21)00218-6 · Cited by 520
Galanis, P., Vraka, I., Fragkou, D., Bilali, A., & Kaitelidou, D. (2021) · Journal of Hospital Infection · doi:10.1016/j.jhin.2020.11.008 · Cited by 333
COVID-19 Transmission, Current Treatment, and Future Therapeutic Strategies
Salian, V. S., Wright, J. A., Vedell, P. T., Nair, S., Li, C., Kandimalla, M., Tang, X., Carmona Porquera, E. M., Kalari, K. R., & Kandimalla, K. K. (2021) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.0c00608 · Cited by 315
SARS-CoV-2 exposure, symptoms and seroprevalence in healthcare workers in Sweden
Rudberg, A.-S., Havervall, S., Månberg, A., Jernbom Falk, A., Aguilera, K., Ng, H., Gabrielsson, L., Salomonsson, A.-C., Hanke, L., Murrell, B., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18848-0 · Cited by 303
Metadata
- Authors
- Wilson, N. M., Norton, A., Young, F. P., & Collins, D. W.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2020-05-08
- Volume
- 75
- Issue
- 8
- Pages
- 1086-1095
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W3016404513
- Cited by
- 329
- References
- 53
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.