Artificial intelligence for detecting electrolyte imbalance using electrocardiography
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Introduction: The detection and monitoring of electrolyte imbalance is essential for appropriate management of many metabolic diseases; however, there is no tool that detects such imbalances reliably and noninvasively. In this study, we developed a deep learning model (DLM) using electrocardiography (ECG) for detecting electrolyte imbalance and validated its performance in a multicenter study. Methods and Results: This retrospective cohort study included two hospitals: 92,140 patients who underwent a laboratory electrolyte examination and an ECG within 30 min were included in this study. A DLM was developed using 83,449 ECGs of 48,356 patients; the internal validation included 12,091 ECGs of 12,091 patients. We conducted an external validation with 31,693 ECGs of 31,693 patients from another hospital, and the result was electrolyte imbalance detection. During internal, the area under the receiving operating characteristic curve (AUC) of a DLM using a 12‐lead ECG for detecting hyperkalemia, hypokalemia, hypernatremia, hyponatremia, hypercalcemia, and hypocalcemia were 0.945, 0.866, 0.944, 0.885, 0.905, and 0.901, respectively. The values during external validation of the AUC of hyperkalemia, hypokalemia, hypernatremia, hyponatremia, hypercalcemia, and hypocalcemia were 0.873, 0.857, 0.839, 0.856, 0.831, and 0.813 respectively. The DLM helped to visualize the important ECG region for detecting each electrolyte imbalance, and it showed how the P wave, QRS complex, or T wave differs in importance in detecting each electrolyte imbalance. Conclusion: The proposed DLM demonstrated high performance in detecting electrolyte imbalance. These results suggest that a DLM can be used for detecting and monitoring electrolyte imbalance using ECG on a daily basis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based Localization
Selvaraju, R. R., Cogswell, M., Das, A., Vedantam, R., Parikh, D., & Batra, D. (2020) · International Journal of Computer Vision · doi:10.1007/s11263-019-01228-7 · Cited by 6,909 · cited 1×
“We used a gradient class activation map as a sensitivity map with the gradient backpropagation method (Selvaraju et al., 2017, 2020).”
MethodAttia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389
Galloway, C. D., Valys, A. V., Shreibati, J. B., Treiman, D. L., Petterson, F. L., Gundotra, V. P., Albert, D. E., Attia, Z. I., Carter, R. E., Asirvatham, S. J., et al. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.0640 · Cited by 318 · cited 5×
“…valvular heart disease, left ventricular hypertrophy, and anemia (Attia, Friedman, et al., 2019; Attia, Kapa, et al., 2019; Attia, Noseworthy, et al., 2019; Cho et al., 2020; Galloway et al., 2019; Jo et al., 2020; Kwon, Cho, et al., 2020; Kwon, Kim, et al., 2020; Kwon, Lee, et al., 2020).”
BackgroundMethodInfluentialDeep Learning–Based Algorithm for Detecting Aortic Stenosis Using Electrocardiography
Kwon, J., Lee, S. Y., Jeon, K., Lee, Y., Kim, K., Park, J., Oh, B., & Lee, M. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.119.014717 · Cited by 224
Self-citationThe pathophysiology of fluid and electrolyte balance in the older adult surgical patient
El-Sharkawy, A. M., Sahota, O., Maughan, R. J., & Lobo, D. N. (2014) · Clinical Nutrition · doi:10.1016/j.clnu.2013.11.010 · Cited by 172 · cited 1×
“Electrolyte balance is important for maintaining homeostasis and protecting cellular function (El-Sharkawy et al., 2014; Rhoda et al., 2011).”
BackgroundLin, C.-S., Lin, C., Fang, W.-H., Hsu, C.-J., Chen, S.-J., Huang, K.-H., Lin, W.-S., Tsai, C.-S., Kuo, C.-C., Chau, T., et al. (2020) · JMIR Medical Informatics · doi:10.2196/15931 · Cited by 109 · cited 1×
“Recent studies have shown that deep learning models can detect dyskale-mia using ECG (Galloway et al., 2019; Lin et al., 2020).”
BackgroundArtificial intelligence for early prediction of pulmonary hypertension using electrocardiography
Kwon, J.-M., Kim, K.-H., Medina-Inojosa, J., Jeon, K.-H., Park, J., & Oh, B.-H. (2020) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2020.04.009 · Cited by 108
Self-citationGeneral characteristics of patients with electrolyte imbalance admitted to emergency department
Balcı, A. K., Koksal, O., Kose, A., Armagan, E., Ozdemir, F., Inal, T., & Oner, N. (2013) · World Journal of Emergency Medicine · doi:10.5847/wjem.j.issn.1920-8642.2013.02.005 · Cited by 85
Cited by
Prospective evaluation of smartwatch-enabled detection of left ventricular dysfunction
Attia, Z. I., Harmon, D. M., Dugan, J., Manka, L., Lopez-Jimenez, F., Lerman, A., Siontis, K. C., Noseworthy, P. A., Yao, X., Klavetter, E. W., et al. (2022) · Nature Medicine · doi:10.1038/s41591-022-02053-1 · Cited by 154
Chung, C. T., Lee, S., King, E., Liu, T., Armoundas, A. A., Bazoukis, G., & Tse, G. (2022) · International Journal of Arrhythmia · doi:10.1186/s42444-022-00075-x · Cited by 79
Self-citationLin, C., Chau, T., Lin, C.-S., Shang, H.-S., Fang, W.-H., Lee, D.-J., Lee, C.-C., Tsai, S.-H., Wang, C.-H., & Lin, S.-H. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00550-0 · Cited by 62
Serum Potassium Monitoring Using AI-Enabled Smartwatch Electrocardiograms
Chiu, I.-M., Wu, P.-J., Zhang, H., Hughes, J. W., Rogers, A. J., Jalilian, L., Perez, M., Lin, C.-H. R., Lee, C.-T., Zou, J., et al. (2024) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2024.07.023 · Cited by 31
Lin, C., Chen, C.-C., Chau, T., Lin, C.-S., Tsai, S.-H., Lee, D.-J., Lee, C.-C., Shang, H.-S., & Lin, S.-H. (2022) · Clinica Chimica Acta · doi:10.1016/j.cca.2022.09.021 · Cited by 10
Metadata
- Authors
- Kwon, J., Jung, M., Kim, K., Jo, Y., Shin, J., Cho, Y., Lee, Y., Ban, J., Jeon, K., Lee, S. Y., Park, J., & Oh, B.
- Venue
- Annals of Noninvasive Electrocardiology
- Publisher
- Wiley
- Published
- 2021-03-15
- Volume
- 26
- Issue
- 3
- Pages
- e12839-e12839
- ISSN
- 1082-720X (ISSN-L)
- 1542-474X
- OpenAlex
- W3136766298
- Cited by
- 62
- References
- 10
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.