Prospective evaluation of smartwatch-enabled detection of left ventricular dysfunction
Open accessAbstract
Although artificial intelligence (AI) algorithms have been shown to be capable of identifying cardiac dysfunction, defined as ejection fraction (EF) ≤ 40%, from 12-lead electrocardiograms (ECGs), identification of cardiac dysfunction using the single-lead ECG of a smartwatch has yet to be tested. In the present study, a prospective study in which patients of Mayo Clinic were invited by email to download a Mayo Clinic iPhone application that sends watch ECGs to a secure data platform, we examined patient engagement with the study app and the diagnostic utility of the ECGs. We digitally enrolled 2,454 unique patients (mean age 53 ± 15 years, 56% female) from 46 US states and 11 countries, who sent 125,610 ECGs to the data platform between August 2021 and February 2022; 421 participants had at least one watch-classified sinus rhythm ECG within 30 d of an echocardiogram, of whom 16 (3.8%) had an EF ≤ 40%. The AI algorithm detected patients with low EF with an area under the curve of 0.885 (95% confidence interval 0.823-0.946) and 0.881 (0.815-0.947), using the mean prediction within a 30-d window or the closest ECG relative to the echocardiogram that determined the EF, respectively. These findings indicate that consumer watch ECGs, acquired in nonclinical environments, can be used to identify patients with cardiac dysfunction, a potentially life-threatening and often asymptomatic condition.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Models which have successfully generalized to wearable device ECGs have relied on automated algorithms to select high-quality subsets of available ECG data, with reduced performance when evaluated on all collected ECGs.
“Additionally, models which have successfully generalized to wearable device ECGs have relied on automated algorithms to select high-quality subsets of available ECG data, with reduced performance when evaluated on all collected ECGs15,26.”
From Detection of left ventricular systolic dysfunction from single-lead electrocardiography adapted for portable and wearable devices (2023) · cites this paper as [26]
The Discussion (page not available) reports that an automated filter selected clean smartwatch ECG tracings and improved AUC to 0.88, compared with 0.85 for the ECG closest in time to the echocardiogram. That supports the benefit of quality selection, but the lower-performance comparison was not an evaluation on all collected ECGs. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Epidemiology and risk profile of heart failure
Bui, A. L., Horwich, T. B., & Fonarow, G. C. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.165 · Cited by 2,077 · see citing works
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., Balasubramanian, V., Russo, A. M., Rajmane, A., Cheung, L., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1901183 · Cited by 1,917 · see citing works
Mobile Photoplethysmographic Technology to Detect Atrial Fibrillation
Guo, Y., Wang, H., Zhang, H., Liu, T., Liang, Z., Xia, Y., Yan, L., Xing, Y., Shi, H., Li, S., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.08.019 · Cited by 489 · see citing works
Ko, W.-Y., Siontis, K. C., Attia, Z. I., Carter, R. E., Kapa, S., Ommen, S. R., Demuth, S. J., Ackerman, M. J., Gersh, B. J., Arruda-Olson, A. M., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.12.030 · Cited by 404 · see citing works
Self-citationGalloway, C. D., Valys, A. V., Shreibati, J. B., Treiman, D. L., Petterson, F. L., Gundotra, V. P., Albert, D. E., Attia, Z. I., Carter, R. E., Asirvatham, S. J., et al. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.0640 · Cited by 318 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 37
- [1]Attia ZI, Harmon DM, Behr ER & Friedman PA Application of artificial intelligence to the electrocardiogram. Eur. Heart J. 42, 4717– 4730 (2021). 34534279 PMC8500024
- [2]Siontis KC, Noseworthy PA, Attia ZI & Friedman PA Artificial intelligence-enhanced electrocardiography in cardiovascular disease management. Nat. Rev. Cardiol. 18, 465– 478 (2021). 33526938 PMC7848866
- [3]Harmon DM, Attia ZI & Friedman PA Current and future implications of the artificial intelligence electrocardiogram: the transformation of healthcare and attendant research opportunities. Cardiovasc. Res. 118, e23– e25 (2022). 35187568 PMC9041336
- [4]Attia ZI Screening for cardiac contractile dysfunction using an artificial intelligence-enabled electrocardiogram. Nat. Med. 25, 70– 74 (2019). 30617318
- [5]Kwon JM Deep learning-based algorithm for detecting aortic stenosis using electrocardiography. J. Am. Heart Assoc. 9, e014717 (2020). 32200712 PMC7428650
- [8]Kwon JM Artificial intelligence for detecting electrolyte imbalance using electrocardiography. Ann. Noninvasive Electrocardiol. 26, e12839 (2021). 33719135 PMC8164149
- [9]Attia ZI An artificial intelligence-enabled ECG algorithm for the identification of patients with atrial fibrillation during sinus rhythm: a retrospective analysis of outcome prediction. Lancet 394, 861– 867 (2019). 31378392
- [10]Echouffo-Tcheugui JB, Erqou S, Butler J, Yancy CW & Fonarow GC Assessing the risk of progression from asymptomatic left ventricular dysfunction to overt heart failure: a systematic overview and meta-analysis. JACC Heart Fail. 4, 237– 248 (2016). 26682794
- [11]Ammar KA Prevalence and prognostic significance of heart failure stages: application of the American College of Cardiology/American Heart Association heart failure staging criteria in the community. Circulation 115, 1563– 1570 (2007). 17353436
- [12]McDonagh TA, McDonald K & Maisel AS Screening for asymptomatic left ventricular dysfunction using B-type natriuretic peptide. Congest Heart Fail 14, 5– 8 (2008). 18772638
- [13]Attia ZI Prospective validation of a deep learning electrocardiogram algorithm for the detection of left ventricular systolic dysfunction. J. Cardiovasc. Electrophysiol. 30, 668– 674 (2019). 30821035
- [14]Attia IZ External validation of a deep learning electrocardiogram algorithm to detect ventricular dysfunction. Int. J. Cardiol. 329, 130– 135 (2021). 33400971 PMC7955278
- [15]Adedinsewo D Artificial intelligence-enabled ECG algorithm to identify patients with left ventricular systolic dysfunction presenting to the emergency department with dyspnea. Circ. Arrhythm. Electrophysiol. 13, e008437 (2020). 32986471
- [16]Noseworthy PA Assessing and mitigating bias in medical artificial intelligence: the effects of race and ethnicity on a deep learning model for ECG analysis. Circ. Arrhythm. Electrophysiol. 13, e007988 (2020). 32064914 PMC7158877
- [17]Yao X Artificial intelligence-enabled electrocardiograms for identification of patients with low ejection fraction: a pragmatic, randomized clinical trial. Nat. Med. 27, 815– 819 (2021). 33958795
- [18]McDonagh TA 2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure. Eur. Heart J. 42, 3599– 3726 (2021). 34447992
- [19]Yancy CW 2017 ACC/AHA/HFSA focused update of the 2013 ACCF/AHA Guideline for the Management of Heart Failure: a report of the American College of Cardiology/American Heart Association Task Force on Cinical Practice Guidelines and the Heart Failure Society of America. Circulation 136, e137– e161 (2017). 28455343
- [20]Pisano ED Diagnostic performance of digital versus film mammography for breast-cancer screening. N. Engl. J. Med. 353, 1773– 1783 (2005). 16169887
- [21]Cárdenas-Turanzas M The accuracy of the Papanicolaou smear in the screening and diagnostic settings. J. Low. Genit. Trac. Dis. 12, 269– 275 (2008). 18820540
- [22]Bhalla V Diagnostic ability of B-type natriuretic peptide and impedance cardiography: testing to identify left ventricular dysfunction in hypertensive patients. Am. J. Hypertens. 18, 73s– 81s (2005). 15752936
- [24]Benjamin ZI Correction to: Heart disease and stroke statistics—2018 update: a report from the American Heart Association. Circulation 137, e493 (2018). 29555722
- [26]Dargie HJ Effect of carvedilol on outcome after myocardial infarction in patients with left-ventricular dysfunction: the CAPRICORN randomised trial. Lancet 357, 1385– 1390 (2001). 11356434
- [27]Pfeffer MA Effect of captopril on mortality and morbidity in patients with left ventricular dysfunction after myocardial infarction. Results of the survival and ventricular enlargement trial. The SAVE Investigators. N. Engl. J. Med. 327, 669– 677 (1992). 1386652
- [29]Grogan M Artificial intelligence-enhanced electrocardiogram for the early detection of cardiac amyloidosis. Mayo Clin. Proc. 96, 2768– 2778 (2021). 34218880
- [30]Ahn JC Development of the AI-cirrhosis-ECG score: an electrocardiogram-based deep learning model in cirrhosis. Am. J. Gastroenterol. 117, 424– 432 (2022). 35029163 PMC9727935
- [31]Bailey JJ Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, American Heart Association. Circulation 81, 730– 739 (1990). 2297875
- [32]Shiner Z, Baharav A & Akselrod S Detection of different recumbent body positions from the electrocardiogram. Med. Biol. Eng. Comput. 41, 206– 210 (2003). 12691442
- [33]Nelwan SP, Meij SH, van Dam TB & Kors JA Correction of ECG variations caused by body position changes and electrode placement during ST-T monitoring. J. Electrocardiol. 34, 213– 216 (2001). 11781959
- [34]Williams GC The impact of posture on cardiac repolarization: more than heart rate? J. Cardiovasc. Electrophysiol. 17, 352– 358 (2006). 16643354
- [35]Schijvenaars BJ, Kors JA, van Herpen G, Kornreich F & van Bemmel JH Effect of electrode positioning on ECG interpretation by computer. J. Electrocardiol. 30, 247– 256 (1997). 9261733
- [36]Heidenreich PA Forecasting the impact of heart failure in the united states: a policy statement from the American Heart Association. Circ. Heart Fail. 6, 606– 619 (2013). 23616602 PMC3908895
- [37]Mozaffarian D Heart disease and stroke—2015 update: a report from the American Heart Association. Circulation 131, e29– e322 (2015). 25520374
- [38]Bahrami H Differences in the incidence of congestive heart failure by ethnicity: the multi-ethnic study of atherosclerosis. Arch. Intern. Med. 168, 2138– 2145 (2008). 18955644 PMC3038918
- [40]Steyerberg EW & Harrell FE Jr. Prediction models need appropriate internal, internal–external, and external validation. J. Clin. Epidemiol. 69, 245– 247 (2016). 25981519 PMC5578404
- [41]Tseng AS Cost effectiveness of an electrocardiographic deep learning algorithm to detect asymptomatic left ventricular dysfunction. Mayo Clinic Proc. 96, 1835– 1844 (2021). 34116837
- [42]Cohen-Shelly M Electrocardiogram screening for aortic valve stenosis using artificial intelligence. Eur. Heart J. 42, 2885– 2896 (2021). 33748852
- [43]Attia ZI Age and sex estimation using artificial intelligence from standard 12-lead ECGs. Circ. Arrhythm. Electrophysiol. 12, e007284 (2019). PMC7661045 31450977
Cited by
Sorted by citations
Putting ChatGPT’s Medical Advice to the (Turing) Test: Survey Study
Nov, O., Singh, N., & Mann, D. (2023) · JMIR Medical Education · doi:10.2196/46939 · Cited by 198 · see citing works
Li, K., Cardoso, C., Moctezuma-Ramirez, A., Elgalad, A., & Perin, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20247146 · Cited by 160 · see citing works
Khunte, A., Sangha, V., Oikonomou, E. K., Dhingra, L. S., Aminorroaya, A., Mortazavi, B. J., Coppi, A., Brandt, C. A., Krumholz, H. M., & Khera, R. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00869-w · Cited by 95 · see citing works
Artificial Intelligence–Enabled Prediction of Heart Failure Risk From Single-Lead Electrocardiograms
Dhingra, L. S., Aminorroaya, A., Pedroso, A. F., Khunte, A., Sangha, V., McIntyre, D., Chow, C. K., Asselbergs, F. W., Brant, L. C. C., Barreto, S. M., et al. (2025) · JAMA Cardiology · doi:10.1001/jamacardio.2025.0492 · Cited by 65 · see citing works
Pediatric ECG-Based Deep Learning to Predict Left Ventricular Dysfunction and Remodeling
Mayourian, J., La Cava, W. G., Vaid, A., Nadkarni, G. N., Ghelani, S. J., Mannix, R., Geva, T., Dionne, A., Alexander, M. E., Duong, S. Q., et al. (2024) · Circulation · doi:10.1161/circulationaha.123.067750 · Cited by 59 · see citing works
Serum Potassium Monitoring Using AI-Enabled Smartwatch Electrocardiograms
Chiu, I.-M., Wu, P.-J., Zhang, H., Hughes, J. W., Rogers, A. J., Jalilian, L., Perez, M., Lin, C.-H. R., Lee, C.-T., Zou, J., et al. (2024) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2024.07.023 · Cited by 31 · see citing works
Digital tools in heart failure: addressing unmet needs
Myhre, P. L., Tromp, J., Ouwerkerk, W., Ting, D. S. W., Docherty, K. F., Gibson, C. M., & Lam, C. S. P. (2024) · The Lancet Digital Health · doi:10.1016/s2589-7500(24)00158-4 · Cited by 31 · see citing works
Naser, J. A., Lee, E., Lopez-Jimenez, F., Noseworthy, P. A., Latif, O. S., Friedman, P. A., Lin, G., Oh, J. K., Scott, C. G., Pislaru, S. V., et al. (2024) · JACC: Advances · doi:10.1016/j.jacadv.2024.101179 · Cited by 8 · see citing works
Self-citationLeveraging the full potential of wearable devices in cardiomyopathies
Oikonomou, E. K., & Khera, R. (2024) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2024.02.011 · Cited by 6 · see citing works
- Authors
- Attia, Z. I., Harmon, D. M., Dugan, J., Manka, L., Lopez-Jimenez, F., Lerman, A., Siontis, K. C., Noseworthy, P. A., Yao, X., Klavetter, E. W., Halamka, J. D., Asirvatham, S. J., Khan, R., Carter, R. E., Leibovich, B. C., & Friedman, P. A.
- Affiliations
- Mayo Clinic (US)
- Corresponding author
- Friedman, Paul A.
- ORCID
- Venue
- Nature Medicine
- Published
- 2022-11-14
- Volume
- 28
- Issue
- 12
- Pages
- 2497-2503
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- PMC
- PMC9805528
- OpenAlex
- W4308994163
- Cited by
- 154
- References
- 5
- Citations by year
- 2026: 37 · 2025: 40 · 2024: 49 · 2023: 27 · 2022: 1
- FWCI
- 20.37
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Nature Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Food and Drug Administration (U01FD006292)
- Agency for Healthcare Research and Quality (R01 HS025402)
- National Institute on Aging (R01AG062436, R21AG062580)
- National Heart, Lung, and Blood Institute (R01HL143070, R01HL131535, R38HL150086)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- smartwatch ECG, left ventricular dysfunction, reduced ejection fraction, artificial intelligence, single-lead ECG, consumer health technology, echocardiography, mobile application, patient engagement, digital health
- MeSH terms
- Adult, Aged, Artificial Intelligence, Electrocardiography, Female, Heart Diseases, Humans, Male, Middle Aged, Prospective Studies, Ventricular Dysfunction, Left
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review