Sex‐related differences in muscle size explained by amplitudes of higher‐threshold motor unit action potentials and muscle fibre typing
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Aim: To investigate the relationships between motor unit action potential amplitudes (MUAP AMP), muscle cross‐sectional area (mCSA) and composition (mEI), per cent myosin heavy chain (%MHC) areas and sex in the vastus lateralis (VL). Methods: Ten males and 10 females performed a submaximal isometric trapezoid muscle action that included a linearly increasing, steady torque at 40% maximal voluntary contraction, and linearly decreasing segments. Surface electromyographic decomposition techniques were utilized to determine MUAP AMPS in relation to recruitment thresholds (RT). Ultrasound images were taken to quantify muscle mCSA and mEI. Muscle biopsies were collected to calculate %MHC areas. Y‐intercepts and slopes were calculated for the MUAP AMP vs RT relationships for each subject. Independent‐samples t tests and ANOVA models examined sex‐related differences in mCSA, mEI, slopes and y‐intercepts for the MUAP AMP vs RT relationships and %MHC areas. Correlations were performed among type IIA and total type II %MHC area, mCSA and the slopes and y‐intercepts for the MUAP AMP vs RT relationships. Results: Males exhibited greater slopes for the MUAP AMP vs RT relationships (P = .003), mCSA (P < .001) and type IIA %MHC (P = .011), whereas females had greater type I %MHC area (P = .010) and mEI (P = .024). The mCSA, type IIA and total II %MHC area variables were correlated (P < .001‐.015, r = .596‐.836) with the slopes from the MUAP AMP vs RT relationships. Conclusion: Sex‐related differences in mCSA and MUAP AMPS of the higher‐threshold MUs were likely the result of larger muscle fibres expressing type II characteristics for males.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Relation between size of neurons and their susceptibility to discharge
Henneman, E. (1957) · Science · doi:10.1126/science.126.3287.1345 · Cited by 1,227
Gender differences in strength and muscle fiber characteristics
Miller, A. E. J., MacDougall, J. D., Tarnopolsky, M. A., & Sale, D. G. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00235103 · Cited by 1,094
Fiber Type Composition of the Vastus Lateralis Muscle of Young Men and Women
Staron, R. S., Hagerman, F. C., Hikida, R. S., Murray, T. F., Hostler, D. P., Crill, M. T., Ragg, K. E., & Toma, K. (2000) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215540004800506 · Cited by 730 · cited 6×
“Consequently, electrophoretic MHC analysis of a homogenized muscle tissue sample provides a valid estimate of the per cent (%) MHC fibre type area for an individual.(20,31,32) Although %MHC fibre type area does not provide direct information regarding the diameters of specific fibres, it will provide an estimate of to…”
BackgroundMethodResultInfluentialBottinelli, R., Canepari, M., Pellegrino, M. A., & Reggiani, C. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021617 · Cited by 565
Skeletal muscle sonography: a correlative study of echogenicity and morphology
Reimers, K., Reimers, C. D., Wagner, S., Paetzke, I., & Pongratz, D. E. (1993) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1993.12.2.73 · Cited by 385 · cited 1×
“In addition, females displayed greater mEI for the VL, likely indicating greater amounts of noncontractile tissue (ie intramuscular fat).(18,36) Despite similar activity levels, males displayed greater contractile tissue (larger mCSA, lower mEI), which might help explain the greater age‐related decline in muscle thick…”
BackgroundMuscle hypertrophy and fast fiber type conversions in heavy resistance-trained women.
Staron, R. S., Malicky, E. S., Leonardi, M. J., Falkel, J. E., Hagerman, F. C., & Dudley, G. A. (1990) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00572189 · Cited by 328 · cited 1×
“After experimental testing, muscle biopsies were taken from the VL with the percutaneous needle biopsy methods of Bergstrom(55) utilizing the double‐chop and suction method.(56,57) For detailed information regarding subject preparation and follow‐up, and biopsy storage, refer to Trevino et al(53) Sodium dodecyl sulpha…”
MethodReduction in hybrid single muscle fiber proportions with resistance training in humans
Williamson, D. L., Gallagher, P. M., Carroll, C. C., Raue, U., & Trappe, S. W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.5.1955 · Cited by 150 · cited 1×
“The fibre type distribution of the entire human VL muscle is similar along the axis of the muscle,(61) and the variations within single‐fibre measurements account for under 2% of a change in fibre type proportion.(62)”
BackgroundNeder, J. A., Nery, L. E., Shinzato, G. T., Andrade, M. S., Peres, C., & Silva, A. C. (1999) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1999.29.2.116 · Cited by 143
Trevino, M. A., Herda, T. J., Fry, A. C., Gallagher, P. M., Vardiman, J. P., Mosier, E. M., & Miller, J. D. (2016) · Journal of Neurophysiology · doi:10.1152/jn.01021.2015 · Cited by 50 · cited 2×
“Each participant was seated on a Biodex System 3 isokinetic dynamometer (Biodex Medical Systems, Shirley, NY, USA) with isometric leg extensor tests performed on the right leg as described earlier.(52,53) Isometric strength was measured using the torque signal from the Biodex System 3 isokinetic dynamometer.”
MethodSelf-citation
Cited by
Nuzzo, J. L. (2023) · Journal of Strength & Conditioning Research · doi:10.1519/jsc.0000000000004329 · Cited by 304
Landen, S., Hiam, D., Voisin, S., Jacques, M., Lamon, S., & Eynon, N. (2023) · The Journal of Physiology · doi:10.1113/jp279499 · Cited by 137
“Therefore, males rely on lower firing rates to modulate contractile force than females (Trevino et al. 2019; Sontag et al. 2021).”
BackgroundWomen at Altitude: Sex-Related Physiological Responses to Exercise in Hypoxia
Raberin, A., Burtscher, J., Citherlet, T., Manferdelli, G., Krumm, B., Bourdillon, N., Antero, J., Rasica, L., Malatesta, D., Brocherie, F., et al. (2024) · Sports Medicine · doi:10.1007/s40279-023-01954-6 · Cited by 70
Metadata
- Authors
- Trevino, M. A., Sterczala, A. J., Miller, J. D., Wray, M. E., Dimmick, H. L., Ciccone, A. B., Weir, J. P., Gallagher, P. M., Fry, A. C., & Herda, T. J.
- Venue
- Acta Physiologica
- Publisher
- Wiley
- Published
- 2018-06-27
- Volume
- 225
- Issue
- 4
- Pages
- e13151-e13151
- ISSN
- 1748-1708 (ISSN-L)
- 1748-1716
- OpenAlex
- W2808037126
- Cited by
- 83
- References
- 9
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.