CoChat

Acute caffeine intake increases muscle oxygen saturation during a maximal incremental exercise test

Open access
Ruíz‐Moreno, Carlos, Lara, Beatriz, Brito de Souza, Diego, Gutiérrez‐Hellín, Jorge, Romero‐Moraleda, Blanca, Cuéllar‐Rayo, Ángel, Del Coso, Juan · 2020 · British Journal of Clinical Pharmacology
Cited by 53

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Aims: The main mechanism behind caffeine's ergogenicity lies in its tendency to bind to adenosine receptors, although other mechanisms might be involved. The aim of this investigation was to analyse the effects of caffeine on muscle oxygen saturation during exercise of increasing intensity. Methods: Thirteen healthy and active individuals volunteered to participate in a randomized, double blind, placebo‐controlled crossover trial. During 2 different trials, participants either ingested a placebo (cellulose) or 3 mg/kg of caffeine. After waiting for 60 min to absorb the substances, participants underwent a maximal ramp cycle ergometer test (25 W/min). Near infrared spectrometers were positioned on each leg's vastus lateralis to monitor tissue O 2 saturation. Blood lactate concentration was measured 1 min after the end of the exercise test. Results: In comparison to the placebo, the ingestion of caffeine improved the maximal wattage (258 ± 50 vs 271 ± 54 W, respectively, P < .001, effect size [ES] = 0.27; 95% confidence interval [CI] 0.14–0.35) and blood lactate concentration (11.9 ± 3.8 vs 13.7 ± 3.5 mmol/L, P = .029, ES = 0.38; 95% CI 0.14–0.75) at the end of the test. Caffeine increased muscle oxygen saturation at several exercise workloads with a main effect found in respect to the placebo (F = 6.28, P = .029; ES = 0.30 to 0.54; 95% CI 0.01–0.78). Peak pulmonary ventilation (124 ± 29 vs 129 ± 23 L/min, P = 0.035, ES = 0.25; 95% CI 0.07–0.40) and peak oxygen uptake (3.18 ± 0.70 vs 3.33 ± 0.88 L/min, P = 0.032, ES = 0.26; 95% CI 0.08–0.51) were also increased with caffeine. Conclusion: Acute ingestion of 3 mg/kg of caffeine improved peak aerobic performance and increased peak pulmonary ventilation. In addition, caffeine induced changes in muscle oxygen saturation during submaximal workloads, suggesting that this mechanism might also contribute to caffeine's ergogenic effect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/bcp.14189

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Ruíz‐Moreno, C., Lara, B., Brito de Souza, D., Gutiérrez‐Hellín, J., Romero‐Moraleda, B., Cuéllar‐Rayo, Á., & Del Coso, J.
Venue
British Journal of Clinical Pharmacology
Publisher
Wiley
Published
2020-01-14
Volume
86
Issue
5
Pages
861-867
ISSN
  • 0306-5251 (ISSN-L)
  • 1365-2125
OpenAlex
W2991323713
Cited by
53
References
11
FWCI
3.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.