Specificity and sensitivity of commercially available assays for glucagon‐like peptide‐1 ( GLP ‐1): implications for GLP ‐1 measurements in clinical studies
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Aims: To evaluate the performances of commercially available glucagon‐like peptide‐1 (GLP‐1) assays and the implications for clinical studies. Methods: Known concentrations (5–300 pmol/l) of synthetic GLP‐1 isoforms (GLP‐1 1‐36NH 2 , 7‐36NH 2 , 9‐36NH 2 , 1‐37, 7‐37 and 9‐37) were added to the matrix (assay buffer) supplied with 10 different kits and to human plasma, and recoveries were determined. Assays yielding meaningful results were analysed for precision and sensitivity by repeated analysis and ability to discriminate low concentrations. Endogenous GLP‐1 levels in clinical samples were assessed using three commercial kits. Results: The USCN LIFE assay detected none of the GLP‐1 isoforms. The active GLP‐1 enzyme‐linked immunosorbent assays (ELISAs) from Millipore and DRG appeared identical and were specific for intact GLP‐1 in buffer and plasma. The Meso Scale Discovery (MSD) total GLP‐1 kit detected all six GLP‐1 isoforms, although recovery of non‐active forms was incomplete, especially in plasma. Millipore total GLP‐1 ELISA kit detected all isoforms in buffer, but mainly amidated forms in plasma. The Alpco, Phoenix and Bio‐Rad kits detected only amidated GLP‐1, but the Alpco kit had a limited measurement range (30 pmol/l), the Phoenix kit had incomplete recovery in plasma and the Bio‐Rad kit was insensitive (detection limit in plasma 40 pmol/l). The pattern of postprandial GLP‐1 responses in clinical samples was similar between the kits tested, but the absolute concentrations measured varied. Conclusions: The specificity and sensitivity of commercially available kits for the analysis of GLP‐1 levels vary considerably. This should be taken into account when selecting which assay to use and when comparing data from different studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deacon, C. F., Johnsen, A. H., & Holst, J. J. (1995) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.80.3.7883856 · Cited by 792
Self-citationAhrén, B., Simonsson, E., Larsson, H., Landin-Olsson, M., Torgeirsson, H., Jansson, P.-A., Sandqvist, M., Båvenholm, P., Efendic, S., Eriksson, J. W., et al. (2002) · Diabetes Care · doi:10.2337/diacare.25.5.869 · Cited by 421
Jørgensen, N. B., Jacobsen, S. H., Dirksen, C., Bojsen-Møller, K. N., Naver, L., Hvolris, L., Clausen, T. R., Wulff, B. S., Worm, D., Lindqvist Hansen, D., et al. (2012) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00073.2012 · Cited by 313
Effect of low- and high-glycemic load on circulating incretins in a randomized clinical trial
Runchey, S. S., Valsta, L. M., Schwarz, Y., Wang, C., Song, X., Lampe, J. W., & Neuhouser, M. L. (2013) · Metabolism · doi:10.1016/j.metabol.2012.07.006 · Cited by 30
Cited by
Steinert, R. E., Feinle-Bisset, C., Asarian, L., Horowitz, M., Beglinger, C., & Geary, N. (2017) · Physiological Reviews · doi:10.1152/physrev.00031.2014 · Cited by 578
“Available GLP-1 assay methods usually yield similar relative changes, but often different absolute concentrations (49, 410).”
BackgroundDiscovery, characterization, and clinical development of the glucagon-like peptides
Drucker, D. J., Habener, J. F., & Holst, J. J. (2017) · Journal of Clinical Investigation · doi:10.1172/jci97233 · Cited by 418
Self-citationThe New Biology and Pharmacology of Glucagon
Müller, T. D., Finan, B., Clemmensen, C., DiMarchi, R. D., & Tschöp, M. H. (2017) · Physiological Reviews · doi:10.1152/physrev.00025.2016 · Cited by 419
“Glicentin and OXM contain the full amino acid sequence of glucagon (aa 33–61 of proglucagon) (FIGURE 2) and consequently immunoassays for glucagon are inherently nonspecific, with cross-reactivity for these larger peptide products (35).”
BackgroundFærch, K., Torekov, S. S., Vistisen, D., Johansen, N. B., Witte, D. R., Jonsson, A., Pedersen, O., Hansen, T., Lauritzen, T., Sandbæk, A., et al. (2015) · Diabetes · doi:10.2337/db14-1751 · Cited by 321
GLP-1 physiology in obesity and development of incretin-based drugs for chronic weight management
Holst, J. J. (2024) · Nature Metabolism · doi:10.1038/s42255-024-01113-9 · Cited by 125
“Some of the early radioimmunoassays for GLP-1 were not particularly accurate, which may have invalidated many measurements 237 .”
Self-citation
Metadata
- Authors
- Bak, M. J., Wewer Albrechtsen, N. J., Pedersen, J., Knop, F. K., Vilsbøll, T., Jørgensen, N. B., Hartmann, B., Deacon, C. F., Dragsted, L. O., & Holst, J. J.
- Venue
- Diabetes, Obesity and Metabolism
- Publisher
- Wiley
- Published
- 2014-07-22
- Volume
- 16
- Issue
- 11
- Pages
- 1155-1164
- ISSN
- 1462-8902 (ISSN-L)
- 1463-1326
- OpenAlex
- W2083290730
- Cited by
- 108
- References
- 4
- FWCI
- 8.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Specificity and sensitivity of commercially available assays for glucagon‐like peptide‐1 ( GLP ‐1): implications for GLP ‐1 measurements in clinical studies. https://app.cochat.ai/papers/10.1111/dom.12352
- The paper
- Bak, M. J., Wewer Albrechtsen, N. J., Pedersen, J., Knop, F. K., Vilsbøll, T., Jørgensen, N. B., Hartmann, B., Deacon, C. F., Dragsted, L. O., & Holst, J. J. (2014). Specificity and sensitivity of commercially available assays for glucagon‐like peptide‐1 ( GLP ‐1): implications for GLP ‐1 measurements in clinical studies. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.12352
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.