Evaluation of an automated algorithm for interpretation of lupus anticoagulant testing

Florin, Lisa, Desloovere, Maxime, Devreese, Katrien M. J.·2019·International Journal of Laboratory Hematology

Abstract

INTRODUCTION: Lupus anticoagulant (LAC) testing is a multistep procedure including screening, mixing, and confirmation tests. STA Coag Expert is a software module for STA R Max and STA Compact Max analyzers which includes an on-demand LAC algorithm, based on ISTH guidelines, for automatic interpretation, calculation, and launch of assays in LAC interpretation ("Stago coag algorithm"). MATERIALS AND METHODS: One hundred ninety four patient samples were analyzed in parallel and interpreted manually and automatically by LAC algorithms. LAC algorithms use identical flowcharts and cutoff values as in daily practice. Differently, it only uses index of circulating anticoagulant (ICA), whereas in routine also normalized ratios were assessed for interpretation of mixing tests. Interpretation of dRVVT and aPTT pathways and final conclusions were compared between both approaches. RESULTS: Compared to routine interpretation, LAC algorithm showed a sensitivity of 94% and a specificity of 100% for LAC detection, when discrepancies due to measured clotting times between both analyzers were excluded. Three false negatives were due to different interpretation of dRVVT mixing test. Discrepancies in interpretation of the aPTT mixing test (n = 11) did not result in discrepant final LAC result, all having negative confirmation tests. No false positives were observed. With LAC algorithm, hands-on time reduced from 200 to 80 minutes. CONCLUSION: The LAC algorithm of the STA Coag Expert shows good comparability to the manual interpretation of LAC and may be used to assist laboratories in automatic launching of additional tests and in interpretation of LAC according to ISTH guidelines. This way the STA Coag Expert LAC algorithm may improve interlaboratory and STA comparability of LAC results.

Integrity signals

Registry

Crossref · 10.1111/ijlh.13001

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Florin, L., Desloovere, M., & Devreese, K. M. J.
Affiliations
Ghent University Hospital (BE)
Corresponding author
Devreese, Katrien M. J.
Venue
International Journal of Laboratory Hematology
Publisher
Wiley
Published
2019-03-12
Volume
41
Issue
3
Pages
412-417
ISSN
  • 1751-5521 (ISSN-L)
  • 1751-553X
OpenAlex
W2921042625
Cited by
12
References
14
Citations by year
2026: 1 · 2025: 3 · 2024: 2 · 2022: 2 · 2020: 4
FWCI
1.14
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Laboratory Hematology (publishedVersion)
  • PubMed (publishedVersion)
  • Ghent University Academic Bibliography (Ghent University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
Keywords
lupus anticoagulant, dilute Russell's viper venom time, activated partial thromboplastin time, anticoagulant screening, laboratory automation, assay comparability
MeSH terms
Algorithms, Blood Coagulation Tests, Humans, Immunoassay, Partial Thromboplastin Time, Software, Reproducibility of Results, Lupus Coagulation Inhibitor, Antiphospholipid Syndrome, Automation, Laboratory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review